Chapter 5 of 10 · 24 min read

Chapter 3: Chromatography

What you will learn

  • The basic idea of chromatography: a stationary phase, a mobile phase, and different rates of movement.

  • Adsorption chromatography: column chromatography and thin layer chromatography (TLC).

  • Partition chromatography: paper chromatography.

  • How to calculate and use the retardation factor, Rf.

  • How colourless spots are made visible, and where chromatography is used.

3.1 The principle

Chromatography separates the parts of a mixture by letting them move at different speeds over a fixed material. The name comes from the Greek word chroma, meaning colour. The method was first used to separate coloured pigments from plants.

Every chromatography has two phases:

  • Stationary phase: a fixed solid, or a liquid held on a solid. It does not move.

  • Mobile phase: a liquid (or gas) that flows over or through the stationary phase, carrying the mixture.

Each component of the mixture is pulled two ways. The stationary phase holds it back; the mobile phase carries it forward. A component held weakly moves fast. A component held strongly moves slowly. Over a distance, the components spread apart.

Picture a crowd walking down a market street lined with sweet shops. People who love sweets keep stopping and fall behind. People who do not care walk straight through. After a few hundred metres the crowd has sorted itself.

3.2 Types of chromatography in the syllabus

TypeStationary phaseMobile phaseBasis of separationExamples
AdsorptionSolid adsorbent: alumina (Al₂O₃) or silica gelLiquid solvent (eluent)Different extents of adsorption on the solidColumn chromatography, TLC
PartitionLiquid (water) held in a solid supportAnother liquid solventDifferent distribution between two liquid phasesPaper chromatography

3.3 Column chromatography

Column chromatography is adsorption chromatography carried out in a glass tube.

  1. A long glass column with a tap at the bottom is packed with an adsorbent, usually alumina or silica gel, as a slurry in the solvent.

  2. The mixture, dissolved in a little solvent, is placed on top of the column.

  3. A suitable solvent or solvent mixture, called the eluent, is allowed to flow down slowly.

  4. Components move down as bands. The least strongly adsorbed component moves fastest and comes out first. The most strongly adsorbed one comes out last.

  5. The liquid coming out (the eluate) is collected in separate fractions. Each fraction is evaporated to get the pure component.

On polar adsorbents like silica gel and alumina, polar compounds stick more strongly. So a non-polar compound usually elutes first. To push off a strongly held polar compound, the polarity of the eluent is raised step by step, for example from hexane to hexane–ethyl acetate mixtures.

Column chromatography is used when you want to separate and collect useful amounts of each component.

3.4 Thin layer chromatography (TLC)

TLC is adsorption chromatography on a thin layer instead of a column.

  1. A thin layer (about 0.2 mm) of silica gel or alumina is spread on a glass plate. This coated plate is called a TLC plate or chromaplate.

  2. A pencil line (the baseline) is drawn about 2 cm from the bottom. A tiny spot of the mixture solution is put on it.

  3. The plate is placed in a closed jar holding a little eluent. The solvent level must be below the baseline, or the spot would wash into the pool.

  4. The solvent rises up the plate by capillary action. Components move up with it, each to a different height.

  5. When the solvent has nearly reached the top, the plate is removed. The highest point reached by the solvent (the solvent front) is marked at once, before it dries.

The position of each spot is described by its retardation factor:

Rf=distance moved by the substance from the baselinedistance moved by the solvent front from the baselineR_f = \frac{\text{distance moved by the substance from the baseline}}{\text{distance moved by the solvent front from the baseline}}

Both distances are measured from the baseline, not from the bottom edge of the plate. The substance distance is measured to the centre of the spot.

A few facts about Rf:

  • Rf has no unit and always lies between 0 and 1. A substance can never move ahead of the solvent carrying it.

  • For a given compound, Rf is fixed only for a given adsorbent, solvent and temperature. Change any of these, and Rf changes.

  • On silica gel, a more polar compound is held more strongly and so has a lower Rf.

Figure 3.1 · TLC plate and Rf measurement
Figure 3.1 · TLC plate and Rf measurement

All three distances start at the baseline: the solvent front is 8.0 cm up, so spot A at 6.0 cm has Rf 0.75 and spot B at 2.0 cm has Rf 0.25.

Making colourless spots visible. Coloured compounds are seen directly. Colourless ones need help:

  • Ultraviolet light: If the plate contains a fluorescent material, the whole plate glows under UV light. Compounds that absorb UV show up as dark spots.

  • Iodine vapour: The plate is placed in a closed jar with a few iodine crystals. Many organic compounds absorb iodine and show up as brown spots.

  • Spray reagents: A reagent is sprayed that reacts with a class of compounds. Ninhydrin solution, for example, is used to show amino acids as coloured spots.

3.5 Paper chromatography (partition chromatography)

In paper chromatography, a strip of special chromatography paper is used. This paper is made of cellulose and holds water tightly in its fibres.

  • The water trapped in the paper is the stationary phase.

  • The solvent (or solvent mixture) that rises up the paper is the mobile phase.

A spot of the mixture is placed near the bottom of the strip, and the strip is hung in a jar with the solvent below the spot. As the solvent rises, each component is shared, or partitioned, between the stationary water and the moving solvent. A component that prefers the moving solvent travels further.

The developed paper with its separated spots is called a chromatogram. Spots are located and Rf values worked out exactly as in TLC.

This is partition chromatography, because separation depends on how each component distributes itself between two liquid phases, not on adsorption onto a solid.

3.6 Applications

UseHow chromatography helpsUsual method
Checking purityA pure compound gives one spot; extra spots mean impuritiesTLC
Identifying a compoundRf matched with a known sample run on the same plateTLC, paper
Following a reactionThe starting-material spot fades and the product spot growsTLC
Separating and collecting componentsBands collected as separate fractionsColumn
Separating pigments, amino acids, sugarsColoured or sprayed spots separatedPaper, TLC

For identification, the unknown and the known compound are spotted side by side on the same plate, and often on top of each other as a co-spot. The same Rf in two different solvent systems is strong evidence that the two are the same compound.

Worked example 3.1: On a TLC plate, a spot moves 3.2 cm from the baseline while the solvent front moves 8.0 cm from the baseline. Find Rf.

Solution: Rf = 3.2 / 8.0 = 0.40.

Worked example 3.2: A compound has Rf = 0.65 in a certain solvent on silica gel. The solvent front is 12 cm above the baseline. How far has the compound moved?

Solution: Distance = Rf × solvent distance = 0.65 × 12 = 7.8 cm.

Worked example 3.3: The baseline is drawn 1.5 cm above the bottom edge of a TLC plate. The solvent front stops 11.5 cm above the bottom edge. The centre of a spot is 6.5 cm above the bottom edge. Find Rf.

Solution: Measure from the baseline. Spot distance = 6.5 − 1.5 = 5.0 cm. Solvent distance = 11.5 − 1.5 = 10.0 cm. Rf = 5.0 / 10.0 = 0.50. Using the bottom edge would wrongly give 6.5/11.5 = 0.57.

Worked example 3.4: Two compounds A and B have Rf values 0.72 and 0.30. If the solvent travels 10 cm, how far apart are their spots?

Solution: A moves 7.2 cm and B moves 3.0 cm. The gap between the spot centres is 4.2 cm.

Worked example 3.5: A mixture of a hydrocarbon, an ester and an alcohol is put on a silica gel column and eluted with hexane, then with increasingly polar solvent mixtures. In what order do they come out?

Solution: Silica gel holds polar compounds more strongly. The non-polar hydrocarbon is held least and comes out first. The ester, of medium polarity, comes next. The alcohol, which can hydrogen bond to the silica, comes out last, once the eluent is polar enough.

Worked example 3.6: An unknown compound X gives one spot with Rf 0.48. A known sample of compound Y gives Rf 0.48 under the same conditions. Can you say X is Y?

Solution: Not yet with certainty. Different compounds can have the same Rf in one solvent. Run X and Y side by side and as a co-spot. If the co-spot stays a single spot, and they also match in a second solvent system, X is very likely Y. The single spot of X also shows that X is pure.

Worked example 3.7: A reaction converts compound P (Rf 0.60) into compound Q (Rf 0.25). TLC of the reaction mixture after 30 minutes shows spots at 0.60 and 0.25. After 2 hours only the spot at 0.25 is seen. What do you conclude?

Solution: At 30 minutes, the reaction was incomplete, since both P and Q were present. At 2 hours, P is used up, so the reaction is complete. This is the most common use of TLC in a laboratory.

Worked example 3.8: In solvent system S1, compounds A and B have Rf values 0.45 and 0.47. What minimum solvent travel would put their spot centres 1.0 cm apart? What should the chemist do?

Solution: Gap = (0.47 − 0.45) × d = 0.02 d. For a 1.0 cm gap, d = 1.0 / 0.02 = 50 cm. No TLC plate is that long. The chemist should choose a different solvent system that gives a larger difference in Rf, rather than a longer plate.

Quick revision

  • Chromatography: components move at different rates between a stationary phase and a mobile phase.

  • Adsorption chromatography: column and TLC; adsorbent is alumina or silica gel.

  • Partition chromatography: paper; stationary phase is water held in the cellulose fibres.

  • Column: the least strongly adsorbed component elutes first; polar eluents push off polar compounds.

  • Rf = distance moved by substance / distance moved by solvent front, both from the baseline. Rf lies between 0 and 1.

  • Rf depends on adsorbent, solvent and temperature. On silica, more polar means lower Rf.

  • Colourless spots: UV light (dark spots on a glowing plate), iodine (brown spots), ninhydrin spray for amino acids.

  • A pure compound gives a single spot.

NEET traps

  • Measuring distances from the bottom edge of the plate instead of from the baseline.

  • Writing Rf as solvent distance over substance distance, which gives a value above 1.

  • Calling paper chromatography adsorption chromatography. It is partition chromatography; the stationary phase is water, not cellulose.

  • Saying the most strongly adsorbed component comes out of the column first. It comes out last.

  • Dipping the baseline below the solvent level in the jar.

  • Treating a matching Rf in one solvent as final proof of identity.

Practice MCQs: Chapter 3

Level 1: Concept check

1. In chromatography, the phase that moves through or over the other is the (a) mobile phase (b) stationary phase (c) adsorbent (d) chromaplate

2. A common adsorbent used in column chromatography is (a) sodium chloride (b) alumina (c) copper(II) oxide (d) calcium chloride

3. The Rf value of a substance is defined as (a) distance moved by the solvent front divided by distance moved by the substance (b) distance moved by the substance multiplied by distance moved by the solvent front (c) time taken by the substance divided by time taken by the solvent (d) distance moved by the substance divided by distance moved by the solvent front

4. Paper chromatography is an example of (a) adsorption chromatography (b) column chromatography (c) partition chromatography (d) gas chromatography

5. In paper chromatography, the stationary phase is (a) the cellulose itself (b) the solvent that rises (c) the air in the jar (d) the water held in the fibres of the paper

6. Colourless amino acid spots on a chromatogram are commonly made visible by spraying (a) ninhydrin solution (b) silver nitrate solution (c) common salt solution (d) lime water

7. In thin layer chromatography, the stationary phase is usually (a) a strip of filter paper (b) glass wool (c) sand (d) a thin layer of silica gel or alumina on a glass plate

8. The Rf value of any substance is always (a) greater than 1 (b) equal to 1 (c) less than 1 (d) negative

9. Chromatography was first used to separate (a) amino acids (b) coloured plant pigments (c) metal ions (d) gases

10. In column chromatography, the component that comes out of the column first is the one that is (a) most strongly adsorbed (b) present in the largest amount (c) heaviest (d) least strongly adsorbed

Level 2: NEET standard

11. In a TLC run, a spot moves 2.8 cm from the baseline while the solvent front moves 7.0 cm from the baseline. The Rf value is (a) 2.5 (b) 0.28 (c) 0.40 (d) 0.70

12. A compound has Rf 0.55. If the solvent front moves 9.0 cm from the baseline, the spot moves (a) 4.95 cm (b) 16.4 cm (c) 5.5 cm (d) 0.61 cm

13. When a developed TLC plate is placed in a jar of iodine vapour, many colourless organic compounds appear as (a) blue spots (b) brown spots (c) green spots (d) red spots

14. On a silica gel plate run with a non-polar solvent, which compound is expected to have the highest Rf? (a) A hydrocarbon (b) A carboxylic acid (c) An alcohol (d) An amino acid

15. A pure compound on a TLC plate gives (a) two spots (b) a long streak with no spot (c) no spot at all (d) a single spot

16. In TLC, the baseline holding the spots must be above the level of the solvent in the jar because otherwise (a) the spots dissolve into the solvent pool instead of moving up the plate (b) Rf becomes greater than 1 (c) capillary action becomes too fast (d) iodine cannot reach the plate

17. A TLC plate containing a fluorescent material is viewed under UV light. Compounds that absorb UV appear as (a) bright red spots (b) dark spots against a glowing background (c) completely invisible patches (d) blue liquid drops

18. Column chromatography is preferred over TLC when we need to (a) only identify a compound (b) check the purity of a tiny sample (c) separate and collect larger amounts of each component (d) make amino acids visible

19. Paper chromatography separates components on the basis of (a) adsorption on cellulose (b) differences in boiling points (c) different distribution between stationary water and the mobile solvent (d) differences in density

20. A strongly adsorbed polar component is usually removed from a silica gel column by (a) changing to a less polar eluent (b) changing to a more polar eluent (c) heating the column to 500 K (d) adding more adsorbent at the top

21. The developed paper showing separated spots is called a (a) chromaplate (b) eluate (c) chromatogram (d) adsorbate

22. The Rf value of a given compound depends mainly on (a) only the length of the plate (b) only the amount of sample spotted (c) the solvent, the adsorbent and the temperature (d) the time of day the plate is run

Level 3: Challenge

23. The baseline on a TLC plate is 1.0 cm above the bottom edge. The solvent front is 9.0 cm above the bottom edge, and a spot centre is 5.0 cm above the bottom edge. The Rf value of the spot is (a) 0.50 (b) 0.56 (c) 0.44 (d) 0.625

24. Compounds A and B have Rf values 0.62 and 0.38 in a solvent. If the solvent front moves 10 cm, the distance between their spot centres is (a) 2.4 cm (b) 1.0 cm (c) 6.2 cm (d) 3.8 cm

25. Two compounds have Rf values 0.30 and 0.34 in a solvent. The minimum distance the solvent must travel for their spot centres to be 1.0 cm apart is (a) 2.5 cm (b) 25 cm (c) 3.4 cm (d) 30 cm

26. An unknown X gives one spot with Rf 0.42 on silica gel in solvent S. A known compound Y gives Rf 0.42 under the same conditions. The best conclusion is that (a) X is certainly Y (b) X is impure (c) X has a higher melting point than Y (d) X may be Y, which should be confirmed by a co-spot and a second solvent system

27. A mixture of P (a hydrocarbon), Q (a ketone) and R (a carboxylic acid) is separated on a silica gel column, starting with hexane and raising the eluent polarity step by step. The order in which they come out is (a) P, Q, R (b) R, Q, P (c) Q, P, R (d) P, R, Q

28. A reaction converts S (Rf 0.6) into T (Rf 0.25). TLC after 1 hour shows both spots; after 3 hours, only the spot at Rf 0.25 is seen. The best conclusion is that (a) the reaction is complete after 3 hours (b) the product T has decomposed (c) no reaction has taken place (d) the solvent system is unsuitable

29. Assertion (A): The Rf value of a compound is always less than 1. Reason (R): In TLC, silica gel acts as the stationary phase. (a) Both true, R explains A (b) Both true, R does not explain A (c) A true, R false (d) A false, R true

30. Statement I: In adsorption chromatography, components separate because they are adsorbed to different extents on the stationary phase. Statement II: In paper chromatography, the stationary phase is water held in the paper. (a) Both true (b) Both false (c) I true, II false (d) I false, II true

Answer key with reasons

QAnsReason
1aThe mobile phase carries the mixture.
2bAlumina and silica gel are the usual adsorbents.
3dRf = substance distance / solvent front distance.
4cSeparation is by distribution between two liquids.
5dWater bound in cellulose is stationary.
6aNinhydrin gives coloured spots with amino acids.
7dA thin coat of adsorbent on glass.
8cA substance cannot overtake the solvent front.
9bChroma means colour; plant pigments were separated first.
10dWeakly held components move fastest.
11c2.8 / 7.0 = 0.40.
12a0.55 × 9.0 = 4.95 cm.
13bIodine absorbed by the compound gives brown spots.
14aThe least polar compound is held least on silica.
15dOne substance, one spot.
16aThe spot would leach into the solvent pool.
17bUV-absorbing spots quench the glow and look dark.
18cColumn fractions give usable amounts.
19cPaper chromatography is partition chromatography.
20bA more polar eluent competes for the adsorbent.
21cThe developed paper is the chromatogram.
22cRf is constant only for fixed conditions.
23a(5.0 − 1.0)/(9.0 − 1.0) = 4/8 = 0.50.
24a6.2 − 3.8 = 2.4 cm.
25b0.04 × d = 1.0 gives d = 25 cm.
26dEqual Rf in one solvent is not proof of identity.
27aLeast polar elutes first; acid is held most.
28aStarting material has been fully used up.
29bBoth true, but R does not explain why Rf is below 1.
30aBoth statements are correct.

Chapter 3 revision sheet

One-page summary

  • Chromatography separates components that move at different speeds between a stationary phase and a mobile phase.

  • Adsorption chromatography: column and TLC; stationary phase is a solid adsorbent (silica gel or alumina).

  • Partition chromatography: paper; stationary phase is water held in the cellulose fibres; the solvent is the mobile phase.

  • Column: the mixture is loaded at the top; the least strongly adsorbed component elutes first.

  • A more polar eluent pushes polar, strongly adsorbed compounds off the column faster.

  • TLC: a thin layer of silica gel on a glass plate; the solvent rises by capillary action.

  • Rf = distance moved by the spot / distance moved by the solvent front, both measured from the baseline.

  • Rf has no unit and lies between 0 and 1.

  • Rf depends on the adsorbent, the solvent and the temperature.

  • On silica, the more polar compound is held more strongly and has the lower Rf.

  • Colourless spots: UV light, iodine vapour (brown spots), ninhydrin for amino acids.

  • One spot suggests a pure compound; extra spots show impurities or a mixture.

  • Uses: separating plant pigments, checking purity, following a reaction, identifying a compound by comparing Rf with a known sample.

Must-remember table

TypeStationary phaseMobile phasePrinciple
ColumnSilica gel or alumina in a tubeEluent (solvent)Adsorption
TLCSilica gel layer on glassSolvent rising by capillarityAdsorption
PaperWater in cellulose fibresSolvent rising up the paperPartition
Rfdistance by spot / distance by solvent frontNo unit0 to 1

Memory aids

  • "Polar Plants, Low Rise": on silica, polar compounds stay planted and have low Rf.

  • "Paper Partitions, Plates and Pillars Adsorb": paper is partition; TLC plates and columns are adsorption.

  • "Front over Front": Rf = spot front distance over solvent front distance, both from the baseline.

  • "UV, I, N": UV light, Iodine, Ninhydrin are the three ways to see colourless spots.

Concept connections

  • Adsorption on a solid surface: Chemistry Book 20: Principles Related to Practical Chemistry.

  • Polarity and H-bonding decide how strongly a compound sticks: Chemistry Book 3: Chemical Bonding and Molecular Structure.

  • Amino acids detected with ninhydrin: Chemistry Book 19: Biomolecules.

Practice MCQs: Chapter 3, Level 4 (new NEET pattern)

31. Match List I with List II.

List IList II
(A) Column chromatography(i) Water held in cellulose fibres
(B) Thin layer chromatography(ii) Adsorbent packed in a glass tube
(C) Paper chromatography(iii) Moves up the plate by capillary action
(D) Developing solvent in TLC(iv) Silica gel spread thinly on a glass plate

(a) A-ii, B-iv, C-i, D-iii (b) A-iv, B-ii, C-i, D-iii (c) A-ii, B-iv, C-iii, D-i (d) A-i, B-iv, C-ii, D-iii

32. Match List I (way of locating spots) with List II (what you see).

List IList II
(A) UV lamp on a fluorescent plate(i) Brown spots
(B) Iodine vapour(ii) Spots seen directly
(C) Ninhydrin spray(iii) Dark spots on a glowing background
(D) Coloured compounds(iv) Coloured spots for amino acids

(a) A-i, B-iii, C-iv, D-ii (b) A-iii, B-iv, C-i, D-ii (c) A-iii, B-i, C-iv, D-ii (d) A-ii, B-i, C-iv, D-iii

33. Match List I (TLC observation) with List II (conclusion).

List IList II
(A) One spot only(i) Very strongly adsorbed
(B) Two separate spots(ii) Probably pure
(C) Spot stays on the baseline(iii) Very weakly adsorbed; Rf close to 1
(D) Spot travels almost with the solvent front(iv) Mixture of at least two compounds

(a) A-iv, B-ii, C-i, D-iii (b) A-ii, B-iv, C-i, D-iii (c) A-ii, B-iv, C-iii, D-i (d) A-i, B-iv, C-ii, D-iii

34. Match List I (term) with List II (meaning).

List IList II
(A) Stationary phase(i) Developed plate or paper showing separated spots
(B) Eluent(ii) Solvent that washes compounds down a column
(C) Chromatogram(iii) Highest point reached by the solvent
(D) Solvent front(iv) Phase that stays fixed

(a) A-ii, B-iv, C-i, D-iii (b) A-iv, B-i, C-ii, D-iii (c) A-iv, B-ii, C-iii, D-i (d) A-iv, B-ii, C-i, D-iii

35. How many of the following statements are correct?

  • A. Rf can never be greater than 1.

  • B. The Rf of a compound depends on the solvent used.

  • C. Paper chromatography is a kind of partition chromatography.

  • D. On silica gel, a more polar compound has a lower Rf.

(a) One (b) Two (c) Three (d) Four

36. Choose the correct set of statements.

  • A. In column chromatography the most strongly adsorbed component comes out first.

  • B. Silica gel and alumina are common adsorbents.

  • C. The baseline must be above the solvent level in the tank.

  • D. Distances for Rf are measured from the top edge of the plate.

(a) A and B only (b) B and C only (c) A, B and C only (d) C and D only

37. How many of the following statements are correct?

  • A. Chromatography can separate the pigments of a green leaf.

  • B. A single spot in one solvent proves beyond doubt that a compound is pure.

  • C. A more polar eluent moves polar compounds down a silica column faster.

  • D. Rf is measured in centimetres.

(a) Three (b) Four (c) Two (d) One

38. Choose the correct set of statements.

  • A. In paper chromatography the mobile phase is the solvent rising up the paper.

  • B. In adsorption chromatography compounds separate because they are adsorbed to different extents.

  • C. Iodine vapour makes colourless organic spots appear brown.

  • D. Ninhydrin is used to detect halogen compounds.

(a) A, B and C only (b) A and D only (c) B, C and D only (d) A and B only

39. A TLC plate (silica gel) has the solvent front 8.0 cm above the baseline. Spot distances from the baseline: P 2.0 cm, Q 5.6 cm, R 7.2 cm. The Rf of Q is: (a) 0.25 (b) 0.70 (c) 0.90 (d) 1.43

40. For the plate in Q39, which statement is correct? (a) R is the most strongly adsorbed (b) Q is the most polar (c) P has Rf 0.20 (d) P is the most polar, and R has Rf 0.90

41. Three lanes on a TLC plate: lane 1 is pure reactant A (Rf 0.6), lane 2 is pure product B (Rf 0.3), lane 3 is the reaction mixture. After 1 hour lane 3 shows spots at Rf 0.6 and 0.3; after 3 hours it shows only the spot at Rf 0.3. The right conclusion is: (a) The reaction was complete at 1 hour (b) No reaction took place (c) The reaction was complete by 3 hours; A is used up (d) B changes back into A

Passage for Q42–43: A mixture of a hydrocarbon X (non-polar), a ketone Y (moderately polar) and a carboxylic acid Z (highly polar) is loaded on a silica gel column. Hexane is run first; later the eluent is made more polar by adding ethyl acetate.

42. The order in which they come out of the column is: (a) X, Y, Z (b) Z, Y, X (c) Y, X, Z (d) X, Z, Y

43. Ethyl acetate is added later because: (a) It makes the column longer (b) It increases the adsorption of Z (c) Hexane dissolves silica gel (d) A more polar eluent competes for the adsorption sites and moves the strongly held Z down

44. A student measured a spot at 3.0 cm and the solvent front at 9.0 cm, both from the bottom edge of the plate. The baseline was drawn 1.0 cm above the bottom edge. The correct Rf is: (a) 0.33 (b) 0.25 (c) 0.375 (d) 0.22

45. Two compounds have Rf 0.42 and 0.48 in solvent S1 (solvent front 10 cm), and Rf 0.30 and 0.55 in solvent S2 (solvent front 8 cm). Which solvent separates them better? (a) S1, because its Rf values are larger (b) S1, because the spots are 6 cm apart (c) S2, because the spots are 2.0 cm apart against 0.6 cm in S1 (d) S2, because both Rf values are below 0.5

Level 4 answer key

QAnsReason
31aColumn and TLC use solid adsorbents; paper holds water; solvent rises by capillarity
32cUV dark spots, iodine brown, ninhydrin for amino acids, coloured seen directly
33bOne spot pure; two spots mixture; baseline = strongly held; front = weakly held
34dStandard meanings
35dAll four are true
36bLeast adsorbed elutes first; distances are from the baseline
37cA and C true; one spot only suggests purity; Rf has no unit
38aNinhydrin detects amino acids
39b5.6/8.0 = 0.70
40dLowest Rf (P, 0.25) is most polar; R = 7.2/8.0 = 0.90
41cReactant spot gone at 3 h
42aLeast polar is least adsorbed and elutes first
43dPolar eluent displaces polar compounds
44b(3.0 − 1.0)/(9.0 − 1.0) = 0.25
45cGaps: 0.06 × 10 = 0.6 cm; 0.25 × 8 = 2.0 cm