Chapter 7: Magnetic Materials
Every material responds to a magnetic field, but in one of three ways: diamagnetic materials are weakly pushed out of a field, paramagnetic ones are weakly pulled in, and ferromagnetic ones are pulled in strongly. Temperature changes the last two, and the B–H hysteresis loop decides which ferromagnet suits which job.
What you will learn
Magnetisation M, magnetic intensity H, susceptibility χ and relative permeability μᵣ.
Diamagnetic, paramagnetic and ferromagnetic substances: properties, origin, examples.
Curie's law for paramagnets and the Curie temperature of ferromagnets.
Domains and the B–H hysteresis loop: retentivity and coercivity.
Choosing materials for permanent magnets, electromagnets and transformer cores.
7.1 Magnetisation and magnetic intensity
Magnetisation M is the net magnetic moment per unit volume of a material:
Its unit is A m²/m³ = A m⁻¹.
Put a material inside a long solenoid with n turns per metre and current I. The field due to the current alone is B₀ = μ₀nI. The material adds its own field μ₀M. So the total field is:
H is called the magnetic intensity. It depends only on the free current, not on the material. Its unit is also A m⁻¹.
For most materials, M is proportional to H:
χ (chi) is the magnetic susceptibility. It is a pure number. Putting this in:
μᵣ is the relative permeability and μ = μ₀μᵣ is the permeability of the material.
| Quantity | Symbol | Unit | Meaning |
|---|---|---|---|
| Magnetic field | B | T | Total field inside the material |
| Magnetic intensity | H | A/m | Part set by free currents (nI in a solenoid) |
| Magnetisation | M | A/m | Moment per unit volume of the material |
| Susceptibility | χ | none | M/H |
| Relative permeability | μᵣ | none | 1 + χ |
7.2 Diamagnetic substances
Behaviour. A diamagnetic material is weakly repelled by a magnet. In a non-uniform field, it moves from the stronger region to the weaker region. A rod of it hung in a uniform field settles perpendicular to the field.
Numbers. χ is small and negative, about −10⁻⁵. So μᵣ is slightly less than 1. Field lines are slightly pushed out of the material.
Origin. The atoms have no net magnetic moment of their own; the electron orbit and spin moments cancel. When a field is applied, the electron orbits adjust and set up a small induced moment opposite to the field (much like Lenz's law). So M points opposite to H.
Temperature. Diamagnetism hardly depends on temperature.
Examples. Bismuth, copper, lead, silicon, gold, water, sodium chloride, nitrogen gas at room conditions.
Every material has this diamagnetic response. In para- and ferromagnetic materials, a stronger effect simply hides it.
Superconductors are perfect diamagnets. Below a critical temperature, they push the field out completely: B = 0 inside, χ = −1, μᵣ = 0. This is the Meissner effect. It lets a magnet float above a cooled superconductor, the idea behind maglev trains.
7.3 Paramagnetic substances
Behaviour. A paramagnetic material is weakly attracted by a magnet. In a non-uniform field, it moves from the weaker region to the stronger region. A rod of it settles parallel to the field.
Numbers. χ is small and positive, about 10⁻⁵ to 10⁻³. μᵣ is slightly more than 1.
Origin. Each atom has a permanent magnetic moment. Without a field, thermal motion keeps the moments pointing randomly, so M = 0. A field lines them up a little, against the jostling of thermal motion.
Temperature: Curie's law. Higher temperature means more jostling and less alignment. Pierre Curie found:
C is the Curie constant and T the absolute temperature. In short: χ is inversely proportional to T. Halve the kelvin temperature, and χ doubles.
Curie's law holds for weak fields and ordinary temperatures. At very low temperature and very strong field, almost all moments line up and M reaches a saturation value.
Examples. Aluminium, sodium, calcium, platinum, oxygen gas (and liquid oxygen), copper chloride.
Liquid oxygen poured between the poles of a strong magnet sticks there. Liquid nitrogen, being diamagnetic, just runs through.
7.4 Ferromagnetic substances
Behaviour. Strongly attracted by a magnet. They move readily from weak to strong field regions and can stay magnetised after the field is removed.
Numbers. χ is large and positive, from hundreds to about 10⁵. μᵣ is very large.
Origin: domains. Atomic moments in a ferromagnet line up spontaneously with their neighbours over small regions called domains, each about 1 mm or less across and containing around 10¹⁷ to 10¹⁸ atoms. Each domain is fully magnetised. In an unmagnetised piece, domains point in random directions and cancel. An applied field makes domains along the field grow and others turn. The piece becomes strongly magnetised.
Examples. Iron, cobalt, nickel, gadolinium, and alloys such as alnico and steel.
Temperature: the Curie temperature. Heat disturbs the alignment inside domains. Above a temperature T_c, called the Curie temperature, the domains break up and the material becomes paramagnetic. Above T_c the susceptibility follows the Curie–Weiss law:
| Material | Curie temperature (approx.) |
|---|---|
| Cobalt | 1394 K |
| Iron | 1043 K |
| Nickel | 631 K |
| Gadolinium | 293 K |
This is why heating a magnet strongly, or hammering it, weakens it. Gadolinium loses its ferromagnetism just above room temperature on a warm day.
7.5 Comparing the three classes
| Property | Diamagnetic | Paramagnetic | Ferromagnetic |
|---|---|---|---|
| Susceptibility χ | Small, negative (about −10⁻⁵) | Small, positive (10⁻⁵ to 10⁻³) | Large, positive (10² to 10⁵) |
| Relative permeability μᵣ | Slightly less than 1 | Slightly more than 1 | Much greater than 1 |
| In a non-uniform field | Moves to weaker field | Moves to stronger field | Moves to stronger field, strongly |
| Rod in a uniform field | Settles perpendicular to B | Settles parallel to B | Settles parallel to B |
| Permanent atomic moment | No | Yes, random | Yes, aligned in domains |
| Effect of temperature | Almost none | χ proportional to 1/T (Curie law) | Becomes paramagnetic above T_c |
| Examples | Bi, Cu, Pb, water, NaCl | Al, Na, Pt, O₂ | Fe, Co, Ni, Gd |
A neat test: fill a U-tube with the liquid and place one limb between magnet poles. A paramagnetic liquid rises in that limb; a diamagnetic one falls.
7.6 Hysteresis: the B–H loop
Take an unmagnetised iron sample inside a solenoid. Increase H from zero. B rises along a curve and levels off at saturation, when all domains are aligned.
Now reduce H to zero. B does not come back to zero. The value left over is the retentivity (or remanence), B_r. The iron has become a magnet.
To bring B to zero, you must apply H in the reverse direction. The size of this reverse H is the coercivity, H_c.
Take H to a large reverse value (reverse saturation) and back again. B traces a closed loop. B lags behind H; this lag is called hysteresis.

When H returns to zero, B stays at the retentivity B_r, and a reverse H equal to the coercivity H_c is needed to wipe it out; steel's wide loop suits permanent magnets, soft iron's narrow loop suits cores.
The area of the loop is the energy lost as heat per unit volume of the material in one cycle of magnetisation. In a transformer running at 50 Hz, the core goes round this loop 50 times a second.
7.7 Choosing a magnetic material
| Use | Needed | Best choice | Why |
|---|---|---|---|
| Permanent magnet | High retentivity and high coercivity | Steel, alnico, ferrite magnets | Stays magnetised and resists demagnetising |
| Electromagnet core | High permeability, low retentivity, low coercivity | Soft iron | Strong field when on, near zero when off |
| Transformer, motor and generator cores | High permeability, thin hysteresis loop (low loss) | Soft iron, silicon steel | Repeated cycling wastes little energy |
Soft iron has a tall, thin loop. Steel has a wider loop with larger coercivity. Soft iron may even have a higher retentivity than steel, but its small coercivity means it loses that magnetism easily.
7.8 Worked examples
Worked example 7.1: A solenoid with 1000 turns per metre carries 2 A. Its core has μᵣ = 400. Find H, B and M.
Solution: H = nI = 2000 A/m. B = μ₀μᵣH = 4π × 10⁻⁷ × 400 × 2000 ≈ 1.0 T. M = (μᵣ − 1)H = 399 × 2000 ≈ 7.98 × 10⁵ A/m. Without the core, B would be only 2.5 mT.
Worked example 7.2: Classify three materials with χ = −2 × 10⁻⁵, χ = 3 × 10⁻⁴ and χ = 800.
Solution: Small negative: diamagnetic. Small positive: paramagnetic. Large positive: ferromagnetic.
Worked example 7.3: A paramagnetic salt has χ = 1.2 × 10⁻⁵ at 300 K. Find χ at 150 K.
Solution: χ is proportional to 1/T. Temperature halves, so χ doubles: 2.4 × 10⁻⁵.
Worked example 7.4: An iron bar of volume 5 cm³ has magnetisation 8 × 10⁵ A/m. Find its magnetic moment.
Solution: m = MV = 8 × 10⁵ × 5 × 10⁻⁶ = 4 A m².
Worked example 7.5: A material has χ = 499. Find μᵣ and B inside it when H = 1000 A/m.
Solution: μᵣ = 1 + χ = 500. B = μ₀μᵣH = 4π × 10⁻⁷ × 500 × 1000 ≈ 0.628 T.
Worked example 7.6: The hysteresis loop of a transformer core encloses 250 J/m³. The core volume is 1000 cm³ and the supply is 50 Hz. Find the power lost as heat.
Solution: Energy per cycle = 250 × 10⁻³ = 0.25 J. Power = 0.25 × 50 = 12.5 W.
Worked example 7.7 (NEET-hard): A paramagnetic sample shows magnetisation 8 A/m at 4 K in a field of 0.6 T. Find its magnetisation at 16 K in a field of 0.2 T, assuming Curie's law holds.
Solution: M is proportional to B₀/T. M₂ = 8 × (0.2/0.6) × (4/16) = 8 × (1/3) × (1/4) ≈ 0.67 A/m.
Quick revision
B = μ₀(H + M); M = χH; μᵣ = 1 + χ; B = μ₀μᵣH.
H and M both have unit A/m; χ and μᵣ have no unit.
Dia: χ small negative, repelled, no permanent moments, temperature independent.
Para: χ small positive, weakly attracted, χ proportional to 1/T (Curie law).
Ferro: χ very large, domains; paramagnetic above Curie temperature.
Superconductor: χ = −1, perfect diamagnet.
Hysteresis loop area = energy loss per unit volume per cycle. Soft iron for cores; steel for permanent magnets.
NEET traps
Saying a ferromagnet becomes diamagnetic above T_c. It becomes paramagnetic.
Using Celsius in Curie's law. T must be in kelvin.
Thinking only some materials are diamagnetic. All materials have it; it is masked in others.
Choosing soft iron for a permanent magnet because of high retentivity. Its coercivity is too low.
Mixing up retentivity (B left at H = 0) and coercivity (reverse H needed to make B = 0).
Writing μᵣ = χ. The correct relation is μᵣ = 1 + χ.
Practice MCQs: Chapter 7
Level 1: Concept check
1. The susceptibility of a diamagnetic substance is (a) large and positive (b) small and positive (c) small and negative (d) exactly zero
2. Which of these is ferromagnetic at room temperature? (a) Nickel (b) Copper (c) Aluminium (d) Bismuth
3. Which of these is paramagnetic? (a) Bismuth (b) Aluminium (c) Water (d) Iron
4. According to Curie's law, the susceptibility of a paramagnetic substance is (a) proportional to T (b) independent of T (c) proportional to T² (d) proportional to 1/T
5. Above its Curie temperature, a ferromagnetic substance becomes (a) diamagnetic (b) paramagnetic (c) a superconductor (d) more strongly ferromagnetic
6. Relative permeability and susceptibility are related by (a) μᵣ = 1 + χ (b) μᵣ = χ (c) μᵣ = 1 − χ (d) μᵣ = 1/χ
7. A material for permanent magnets should have (a) low retentivity and low coercivity (b) high retentivity and low coercivity (c) high retentivity and high coercivity (d) low retentivity and high coercivity
8. A superconductor below its critical temperature has susceptibility (a) +1 (b) zero (c) very large (d) −1
9. A diamagnetic substance placed in a non-uniform magnetic field moves (a) from the stronger to the weaker region (b) from the weaker to the stronger region (c) not at all (d) along the field lines toward the north pole
10. The area enclosed by a B–H hysteresis loop gives (a) the retentivity (b) the energy lost per unit volume per cycle (c) the coercivity (d) the permeability
Level 2: NEET standard
11. A solenoid with 1000 turns per metre carries 2 A; its core has μᵣ = 400. The field inside is about (a) 0.5 T (b) 2.0 T (c) 1.0 T (d) 0.1 T
12. The magnetisation of the core in Q11 is about (a) 7.98 × 10⁵ A/m (b) 2.0 × 10³ A/m (c) 8.0 × 10² A/m (d) 1.6 × 10⁶ A/m
13. A paramagnetic salt has χ = 1.2 × 10⁻⁵ at 300 K. At 150 K its χ is (a) 0.6 × 10⁻⁵ (b) 1.2 × 10⁻⁵ (c) 4.8 × 10⁻⁵ (d) 2.4 × 10⁻⁵
14. A paramagnetic sample has magnetisation 8 A/m at 4 K in 0.6 T. At 16 K in 0.2 T, its magnetisation is about (a) 2.67 A/m (b) 0.67 A/m (c) 6 A/m (d) 1.33 A/m
15. Soft iron is preferred for transformer cores because it has (a) high coercivity and wide hysteresis loop (b) low permeability (c) high permeability and a thin hysteresis loop (d) a negative susceptibility
16. Which of these has relative permeability slightly less than 1? (a) Aluminium (b) Bismuth (c) Iron (d) Oxygen
17. A transformer core of volume 1000 cm³ has a hysteresis loop of area 250 J/m³ and runs at 50 Hz. The power lost to hysteresis is (a) 0.25 W (b) 5 W (c) 125 W (d) 12.5 W
18. Liquid oxygen poured between the poles of a strong magnet (a) is held between the poles (b) is pushed away from the poles (c) freezes (d) is not affected
19. Which pair of quantities has the same SI unit? (a) B and H (b) B and M (c) H and M (d) χ and H
20. A diamagnetic liquid fills a U-tube, and one limb is placed between the poles of a strong magnet. The liquid level in that limb (a) rises (b) does not change (c) rises and then falls (d) falls
21. An iron bar of volume 5 cm³ has magnetisation 8 × 10⁵ A/m. Its magnetic moment is (a) 0.4 A m² (b) 4 A m² (c) 40 A m² (d) 1.6 × 10¹¹ A m²
22. The susceptibility of a diamagnetic substance (a) is almost independent of temperature (b) increases as temperature rises (c) varies as 1/T (d) becomes positive above a critical temperature
Level 3: Challenge
23. Thin rods of a diamagnetic, a paramagnetic and a ferromagnetic material hang freely in a uniform horizontal magnetic field. They settle (a) all parallel to the field (b) all perpendicular to the field (c) para and ferro parallel, dia perpendicular to the field (d) dia and para parallel, ferro perpendicular to the field
24. A material has χ = 499. In a magnetic intensity of 1000 A/m, B inside it is about (a) 0.314 T (b) 0.5 T (c) 6.28 T (d) 0.628 T
25. Above its Curie temperature, a material has χ = 2 × 10⁻³ at 100 K above T_c. Following the Curie–Weiss law, at 400 K above T_c its χ is (a) 5 × 10⁻⁴ (b) 1 × 10⁻³ (c) 8 × 10⁻³ (d) 2.5 × 10⁻⁴
26. The core of an electromagnet should have (a) high retentivity and high coercivity (b) high permeability and low coercivity (c) low permeability and high coercivity (d) negative susceptibility
27. In an unmagnetised piece of iron, (a) there are no domains (b) all domains point the same way (c) domains exist but point in random directions (d) atoms have no magnetic moments
28. The magnetisation of a paramagnetic sample reaches saturation when (a) temperature is high and field is weak (b) temperature is high and field is strong (c) temperature is low and field is weak (d) temperature is low and field is strong
29. Assertion (A): Soft iron is used for the cores of electromagnets. Reason (R): Soft iron has a high Curie temperature. (a) Both true, R explains A (b) Both true, R does not explain A (c) A true, R false (d) A false, R true
30. Statement I: The susceptibility of a paramagnetic substance rises as its temperature falls. Statement II: Above its Curie temperature, a ferromagnetic substance behaves as a paramagnetic one. (a) Both true (b) Both false (c) I true, II false (d) I false, II true
Answer key with reasons
| Q | Ans | Reason |
|---|---|---|
| 1 | c | Induced moments oppose the field. |
| 2 | a | Fe, Co, Ni, Gd are ferromagnetic. |
| 3 | b | Al has permanent atomic moments. |
| 4 | d | χ = Cμ₀/T. |
| 5 | b | Domains break up above T_c. |
| 6 | a | B = μ₀(1 + χ)H. |
| 7 | c | Must keep magnetism and resist demagnetising. |
| 8 | d | Perfect diamagnet, B = 0 inside. |
| 9 | a | Repelled from strong field regions. |
| 10 | b | Loop area = heat per unit volume per cycle. |
| 11 | c | 4π × 10⁻⁷ × 400 × 2000 ≈ 1.0 T. |
| 12 | a | (μᵣ − 1)H = 399 × 2000. |
| 13 | d | Halving T doubles χ. |
| 14 | b | 8 × (1/3) × (1/4) ≈ 0.67 A/m. |
| 15 | c | Strong response, low loss per cycle. |
| 16 | b | Bismuth is diamagnetic. |
| 17 | d | 250 × 10⁻³ × 50 = 12.5 W. |
| 18 | a | Oxygen is paramagnetic. |
| 19 | c | Both in A/m. |
| 20 | d | Diamagnetic liquid is pushed out of the strong field. |
| 21 | b | MV = 8 × 10⁵ × 5 × 10⁻⁶. |
| 22 | a | Diamagnetism does not rely on aligning permanent moments. |
| 23 | c | Attracted materials align along B; dia turns across it. |
| 24 | d | 4π × 10⁻⁷ × 500 × 1000. |
| 25 | a | χ proportional to 1/(T − T_c): 2 × 10⁻³ × 100/400. |
| 26 | b | Strong when on, easily demagnetised when off. |
| 27 | c | Random domains cancel overall. |
| 28 | d | Thermal disorder small, aligning field large. |
| 29 | b | Both true; the real reason is high permeability and low coercivity. |
| 30 | a | Curie law; and ferro turns para above T_c. |
Chapter 7 revision sheet
One-page summary
Magnetisation M = net magnetic moment per unit volume; unit A/m.
Magnetic intensity H = nI for a solenoid; unit A/m. B = μ₀(H + M).
Susceptibility χ = M/H (no unit); relative permeability μᵣ = 1 + χ; μ = μ₀μᵣ.
Diamagnetic: χ small and negative (about −10⁻⁵), weakly repelled, moves from strong to weak field.
Diamagnetism comes from induced moments opposing B; atoms have no net permanent moment. It barely depends on temperature.
Examples of diamagnets: bismuth, copper, lead, silicon, water, nitrogen gas, sodium chloride.
A superconductor below its critical temperature is a perfect diamagnet: χ = −1 (Meissner effect).
Paramagnetic: χ small and positive (about 10⁻⁵ to 10⁻³), weakly attracted; atoms have permanent moments.
Curie law: M = C B/T, so χ ∝ 1/T for a paramagnet.
Examples of paramagnets: aluminium, sodium, calcium, oxygen (liquid O₂ clings to magnet poles), copper chloride.
Ferromagnetic: χ very large (10³ and more); domains align; examples iron, cobalt, nickel, gadolinium.
Above the Curie temperature a ferromagnet becomes paramagnetic: χ = C/(T − T_c).
Hysteresis: retentivity = B left at H = 0; coercivity = reverse H to make B zero; loop area = energy lost per cycle per unit volume.
Permanent magnets (steel, alnico): high retentivity and high coercivity. Cores of electromagnets and transformers (soft iron): low coercivity, narrow loop.
Must-remember table
| Property | Diamagnetic | Paramagnetic | Ferromagnetic |
|---|---|---|---|
| χ | small, negative | small, positive | large, positive |
| μᵣ | slightly less than 1 | slightly more than 1 | much more than 1 |
| In a non-uniform field | moves to weaker field | moves to stronger field | strongly pulled to stronger field |
| Field lines | slightly pushed out | slightly pulled in | strongly pulled in |
| Temperature effect | almost none | χ ∝ 1/T | paramagnetic above T_c |
| Examples | Bi, Cu, water | Al, Na, O₂ | Fe, Co, Ni, Gd |
Memory aids
"DIA = Dislikes, PARA = Pals, FERRO = Fans": diamagnets are repelled, paramagnets weakly attracted, ferromagnets strongly attracted.
"Cold Paramagnets Comply": lower temperature means larger χ (Curie law).
"Curie crosses to Para": above the Curie temperature a ferromagnet turns paramagnetic.
"Steel Stays, Soft iron Switches": steel keeps its magnetism (permanent magnets); soft iron loses it easily (cores).
"Rem-Rest, Co-Cancel": retentivity is what remains at rest (H = 0); coercivity is what cancels B.
Concept connections
Hysteresis loss and laminated soft-iron cores matter for transformers in Physics Book 14: Electromagnetic Induction and Alternating Currents.
Paramagnetism from unpaired electrons links to Chemistry Book 11: d- and f-Block Elements and Chemistry Book 12: Coordination Compounds.
O₂ being paramagnetic is explained by molecular orbital theory in Chemistry Book 3: Chemical Bonding and Molecular Structure.
Practice MCQs: Chapter 7, Level 4 (new NEET pattern)
31. Match each material (at room temperature unless stated) with its magnetic class.
List I:
A. Bismuth
B. Aluminium
C. Nickel
D. A superconductor below its critical temperature
List II:
(i) paramagnetic
(ii) perfect diamagnet, χ = −1
(iii) diamagnetic
(iv) ferromagnetic
(a) A-i, B-iii, C-iv, D-ii (b) A-iii, B-iv, C-i, D-ii (c) A-iii, B-i, C-ii, D-iv (d) A-iii, B-i, C-iv, D-ii
32. Match each quantity with its relation or unit.
List I:
A. Magnetisation M
B. Susceptibility χ
C. Relative permeability μᵣ
D. B inside a material
List II:
(i) 1 + χ
(ii) μ₀(H + M)
(iii) moment per unit volume, A/m
(iv) M/H, no unit
(a) A-iii, B-iv, C-i, D-ii (b) A-iv, B-iii, C-i, D-ii (c) A-iii, B-i, C-iv, D-ii (d) A-iii, B-iv, C-ii, D-i
33. Match each class with its typical susceptibility.
List I:
A. Diamagnetic
B. Paramagnetic
C. Ferromagnetic
D. Superconductor
List II:
(i) about 10³ or more
(ii) about −10⁻⁵
(iii) exactly −1
(iv) about +10⁻⁵ to +10⁻³
(a) A-iv, B-ii, C-i, D-iii (b) A-ii, B-i, C-iv, D-iii (c) A-ii, B-iv, C-i, D-iii (d) A-iii, B-iv, C-i, D-ii
34. Match each hysteresis term with its meaning.
List I:
A. Retentivity
B. Coercivity
C. Area of the B–H loop
D. Saturation
List II:
(i) reverse H needed to bring B to zero
(ii) energy lost per cycle per unit volume
(iii) all domains aligned; B barely rises further
(iv) B left when H returns to zero
(a) A-i, B-iv, C-ii, D-iii (b) A-iv, B-i, C-ii, D-iii (c) A-iv, B-ii, C-i, D-iii (d) A-iii, B-i, C-ii, D-iv
35. How many of the following statements are correct?
A. Diamagnetic susceptibility hardly depends on temperature.
B. For a paramagnet, χ ∝ 1/T.
C. Above its Curie temperature, a ferromagnet becomes paramagnetic.
D. A diamagnetic rod hung in a strong uniform field turns to lie along the field.
E. A paramagnetic liquid in a U-tube rises in the limb placed between the magnet poles.
(a) 2 (b) 3 (c) 5 (d) 4
36. Choose the correct set of statements about material for a permanent magnet.
A. It should have high retentivity.
B. It should have high coercivity.
C. Low hysteresis loss is its most important need.
D. Steel is a better choice than soft iron.
(a) A and B only (b) A, B and D only (c) B, C and D only (d) A, B, C and D
37. Choose the correct set of statements about material for a transformer core.
A. It should have low coercivity.
B. It should have a narrow hysteresis loop.
C. Soft iron is suitable.
D. It should have high coercivity.
(a) A, B and C only (b) A and D only (c) B and D only (d) C and D only
38. How many of the following statements are correct?
A. Field lines crowd into a ferromagnetic sample.
B. Field lines are slightly pushed out of a diamagnetic sample.
C. Every material shows some diamagnetism.
D. Ferromagnetism belongs to single isolated atoms, not to domains.
(a) 4 (b) 2 (c) 3 (d) 1
39. For a paramagnetic salt obeying Curie law, the graph of χ against 1/T is (a) a horizontal line (b) a straight line through the origin (c) a parabola (d) a falling straight line with a positive intercept
40. The table gives χ of a paramagnetic salt: 200 K gives 3.0 × 10⁻⁴; 300 K gives 2.0 × 10⁻⁴. At 400 K, χ is (a) 1.0 × 10⁻⁴ (b) 1.33 × 10⁻⁴ (c) 2.5 × 10⁻⁴ (d) 1.5 × 10⁻⁴
41. Two B–H loops are described. Material P has a wide, tall loop (large retentivity and coercivity). Material Q has a tall, very narrow loop (small coercivity). The best use is (a) P for permanent magnets, Q for transformer cores (b) P for transformer cores, Q for permanent magnets (c) both for permanent magnets (d) both for transformer cores
Case for Q42–43: A long solenoid has 1000 turns per metre and carries 2 A. It is filled with an iron core of relative permeability 500 (assume the iron stays below saturation).
42. The field B inside the core is about (a) 2.5 mT (b) 0.63 T (c) 2.51 T (d) 1.26 T
43. The magnetisation M of the core is about (a) 2.0 × 10³ A/m (b) 5.0 × 10⁵ A/m (c) 1.0 × 10⁶ A/m (d) 1.0 × 10³ A/m
44. Above its Curie temperature of 1000 K, a ferromagnetic material has χ = 5 × 10⁻³ at 1100 K. Using χ = C/(T − T_c), its χ at 1200 K is (a) 4.6 × 10⁻³ (b) 2.5 × 10⁻³ (c) 1.25 × 10⁻³ (d) 5.0 × 10⁻³
45. An iron bar of volume 2 × 10⁻⁵ m³ has magnetisation 5 × 10⁵ A/m along its length. It is placed at 30° to a uniform field of 0.2 T. The torque on it is (a) 1.0 N m (b) 2.0 N m (c) 0.5 N m (d) 1.73 N m
Level 4 answer key
| Q | Ans | Reason |
|---|---|---|
| 31 | d | Bi dia, Al para, Ni ferro, superconductor χ = −1 |
| 32 | a | M in A/m; χ = M/H; μᵣ = 1 + χ; B = μ₀(H + M) |
| 33 | c | Small negative, small positive, large, −1 |
| 34 | b | Retentivity remains; coercivity cancels; area = loss; saturation = all aligned |
| 35 | d | Only D false: a diamagnetic rod sets across the field |
| 36 | b | C false: loss matters for cores, not permanent magnets |
| 37 | a | D false: cores need low coercivity |
| 38 | c | D false: ferromagnetism needs domains of many atoms |
| 39 | b | χ = C′/T is linear in 1/T |
| 40 | d | χT constant = 0.06; 0.06/400 = 1.5 × 10⁻⁴ |
| 41 | a | Wide loop holds magnetism; narrow loop wastes little energy |
| 42 | d | B = μ₀μᵣnI = 4π × 10⁻⁷ × 500 × 2000 = 1.26 T |
| 43 | c | M = (μᵣ − 1)H = 499 × 2000 ≈ 1.0 × 10⁶ A/m |
| 44 | b | C = 5 × 10⁻³ × 100 = 0.5; 0.5/200 |
| 45 | a | m = MV = 10 A m²; τ = 10 × 0.2 × 0.5 |