Chapter 4 of 9 · 22 min read

Chapter 2: Measuring Instruments and Least Count

What you will learn

  • What least count means and why it limits every measurement

  • How to read vernier callipers and a screw gauge, including zero error

  • How very large and very small distances are measured

  • How mass and time are measured across their huge ranges

2.1 Least count

The least count (LC) of an instrument is the smallest value it can measure reliably. A metre scale has 1 mm marks, so its least count is 1 mm. You cannot honestly read 2.37 mm on it.

InstrumentTypical least count
Metre scale1 mm
Vernier callipers0.1 mm (0.01 cm)
Screw gauge0.01 mm (0.001 cm)
Spherometer0.01 mm
Stopwatch0.01 s

The smaller the least count, the more precise the instrument.

2.2 Vernier callipers

A metre scale cannot read below 1 mm. Vernier callipers add a small sliding scale, the vernier scale, which lets us read a fraction of a main scale division.

Parts:

  • Main scale: fixed, marked in mm.

  • Vernier scale: slides along the main scale.

  • Outside jaws: grip an object to measure outer diameter or length.

  • Inside jaws: fit inside a tube to measure inner diameter.

  • Depth rod: a thin strip that comes out of the end to measure depth of a beaker or hole.

  • Locking screw: holds the vernier in place while you read.

Figure 2.1 · Vernier callipers, parts and a sample reading
Figure 2.1 · Vernier callipers, parts and a sample reading

The vernier zero sits just past the 12 mm mark, so MSR = 1.2 cm; vernier mark 4 meets a main-scale mark, giving 1.24 cm.

How the least count arises. Usually n vernier divisions (VSD) are made equal in length to (n − 1) main scale divisions (MSD):

n VSD=(n−1) MSD  ⇒  1 VSD=(1−1n)MSDn\,\text{VSD} = (n-1)\,\text{MSD} \;\Rightarrow\; 1\,\text{VSD} = \left(1-\frac{1}{n}\right)\text{MSD}
LC=1 MSD−1 VSD=1 MSDn\text{LC} = 1\,\text{MSD} - 1\,\text{VSD} = \frac{1\,\text{MSD}}{n}

For the common design, 10 VSD = 9 MSD and 1 MSD = 1 mm, so LC = 1 mm / 10 = 0.1 mm = 0.01 cm.

Taking a reading:

Reading=MSR+(VSC×LC)\text{Reading} = \text{MSR} + (\text{VSC} \times \text{LC})
  • MSR (main scale reading): the main scale mark just to the left of the vernier zero.

  • VSC (vernier scale coincidence): the number of the vernier mark that lines up exactly with some main scale mark.

Zero error. Close the jaws fully. If the vernier zero does not sit on the main scale zero, the instrument has a zero error.

  • Vernier zero to the right of main zero: positive zero error = +(VSC × LC).

  • Vernier zero to the left of main zero: negative zero error = −(n − VSC) × LC, where VSC is the vernier mark that coincides.

Corrected reading=Observed reading−(zero error with sign)\text{Corrected reading} = \text{Observed reading} - (\text{zero error with sign})

Worked example 2.1: A vernier has LC = 0.01 cm. With the jaws closed, the vernier zero is to the right of main zero and the 4th vernier mark coincides. A ball gives MSR = 2.1 cm and VSC = 7. Find its diameter.

Solution: Zero error = +4 × 0.01 = +0.04 cm. Observed = 2.1 + 7 × 0.01 = 2.17 cm. Corrected = 2.17 − 0.04 = 2.13 cm.

Worked example 2.2: A vernier has 10 divisions. With jaws closed, the vernier zero is to the left of main zero and the 6th vernier mark coincides. LC = 0.01 cm. Find the zero error.

Solution: Negative zero error = −(10 − 6) × 0.01 = −0.04 cm. Any later reading has 0.04 cm added to it.

2.3 Screw gauge (micrometer)

A screw gauge measures thin objects such as wire diameter or sheet thickness. It works on the idea that a screw moves forward a fixed distance for each full turn.

Parts:

  • U-shaped frame holding everything together.

  • Anvil: the fixed stud against which the object rests.

  • Spindle: the moving screw that closes on the object.

  • Sleeve with main (linear) scale, marked in mm or half-mm, with a reference line.

  • Thimble with circular scale, usually 50 or 100 divisions.

  • Ratchet: slips once the spindle grips the object, so you don't over-tighten.

Figure 2.2 · Screw gauge, parts and a sample reading
Figure 2.2 · Screw gauge, parts and a sample reading

The thimble edge has passed the 3 mm mark on the sleeve, and circular division 35 sits on the reference line.

Pitch and least count:

Pitch=distance moved by spindlenumber of full rotations\text{Pitch} = \frac{\text{distance moved by spindle}}{\text{number of full rotations}}
LC=Pitchnumber of divisions on circular scale\text{LC} = \frac{\text{Pitch}}{\text{number of divisions on circular scale}}

Common gauges: pitch 0.5 mm with 50 divisions, or pitch 1 mm with 100 divisions. Both give LC = 0.01 mm.

Reading:

Reading=MSR+(CSR×LC)\text{Reading} = \text{MSR} + (\text{CSR} \times \text{LC})

CSR is the circular scale division that lines up with the reference line.

Zero error. Close the spindle on the anvil gently (use the ratchet).

  • Circular zero below the reference line (n divisions have passed): positive zero error = +n × LC.

  • Circular zero above the reference line (the line meets division N − n): negative zero error = −n × LC, where N is the total number of divisions.

Backlash error. In a worn screw, reversing the direction of turning moves the thimble a little before the spindle moves. Avoid it by always turning in one direction while measuring.

Worked example 2.3: A screw gauge has pitch 1 mm and 100 circular divisions. With nothing between the studs, the circular zero is 4 divisions below the reference line. For a wire, MSR = 3 mm and CSR = 35. Find the diameter.

Solution: LC = 1/100 = 0.01 mm. Zero error = +4 × 0.01 = +0.04 mm. Observed = 3 + 35 × 0.01 = 3.35 mm. Corrected = 3.35 − 0.04 = 3.31 mm.

2.4 Measuring large distances: the parallax method

Hold a pencil at arm's length. Close one eye, then the other. The pencil seems to jump against the background. This shift is called parallax. The distance between the two viewing points (your eyes) is the basis, b.

To find the distance D of a far object, view it from two points a distance b apart and measure the angle θ between the two lines of sight. Because θ is very small, the arc is almost a straight line:

θ=bD⇒D=bθ  (θ in radians)\theta = \frac{b}{D} \quad\Rightarrow\quad D = \frac{b}{\theta}\;(\theta \text{ in radians})
Figure 2.3 · Parallax method
Figure 2.3 · Parallax method

The farther the object, the smaller the angle between the two lines of sight for the same basis.

Once D is known, the size d of the object follows from its angular diameter α:

d=D αd = D\,\alpha

Worked example 2.4: The Moon's angular diameter is 0.5° and its distance is 3.84 × 10⁸ m. Find its diameter.

Solution: α = 0.5 × π/180 = 8.73 × 10⁻³ rad. d = 3.84 × 10⁸ × 8.73 × 10⁻³ ≈ 3.35 × 10⁶ m.

Convert degrees to radians: multiply by π/180. Also, 1′ (minute) = 1/60 degree and 1″ (second) = 1/3600 degree ≈ 4.85 × 10⁻⁶ rad.

2.5 Measuring very small distances

  • Optical microscope: resolves down to about the wavelength of visible light, roughly 0.4–0.7 μm.

  • Electron microscope: uses electron beams whose wavelength can be about 1 Å (10⁻¹⁰ m), so it can reveal much finer detail.

  • Size of a molecule (oleic acid method): dissolve a known tiny volume V of oleic acid in alcohol and drop it on water dusted with powder. It spreads into a layer one molecule thick over area A. The molecule's size is about:

t=VAt = \frac{V}{A}

Worked example 2.5: A drop contains 2 × 10⁻¹⁰ m³ of oleic acid and forms a film of area 0.4 m². Estimate the molecular size.

Solution: t = 2 × 10⁻¹⁰ / 0.4 = 5 × 10⁻¹⁰ m.

2.6 Measuring mass

Mass is usually measured with a common balance, by comparison with standard masses. Masses of atoms and molecules are found with a mass spectrograph, where a charged particle's path in a magnetic field depends on its mass. Masses in nature range from about 10⁻³⁰ kg (electron) to about 10⁵⁵ kg (observable universe).

2.7 Measuring time

Pendulum clocks, quartz clocks and atomic clocks keep time, in increasing order of accuracy. A caesium atomic clock is accurate to about 1 part in 10¹³: it gains or loses less than about 3 microseconds in a year. Times in nature range from about 10⁻²² s (light crossing a nucleus) to about 10¹⁷ s (age of the universe).

Quick revision

  • Vernier: LC = 1 MSD − 1 VSD = MSD/n; reading = MSR + VSC × LC.

  • Screw gauge: LC = pitch / circular divisions; reading = MSR + CSR × LC.

  • Corrected reading = observed − zero error (with its sign).

  • Vernier zero right of main zero, or circular zero below reference line: positive zero error.

  • Parallax: D = b/θ; size d = Dα; θ in radians.

  • Molecular size ≈ V/A.

NEET traps

  • Forgetting the sign of zero error. Subtracting a negative error means adding.

  • For a negative vernier error, the error is (n − VSC) × LC, not VSC × LC.

  • Using θ in degrees in D = b/θ. Always convert to radians.

  • Pitch is distance per rotation, not per division.

  • Precision depends on least count; accuracy depends on how close the value is to the truth (Chapter 3).

Practice MCQs: Chapter 2

1. In vernier callipers, 10 VSD = 9 MSD and 1 MSD = 1 mm. The least count is: (a) 1 mm (b) 0.1 mm (c) 0.01 mm (d) 0.9 mm

2. In a vernier, 20 VSD coincide with 19 MSD, and 1 MSD = 0.5 mm. The least count is: (a) 0.05 mm (b) 0.025 mm (c) 0.5 mm (d) 0.01 mm

3. A screw gauge has pitch 0.5 mm and 50 circular divisions. Its least count is: (a) 0.01 mm (b) 0.05 mm (c) 0.1 mm (d) 0.001 mm

4. With LC = 0.01 cm, MSR = 2.4 cm and the 6th vernier mark coincides. The reading is: (a) 2.406 cm (b) 2.46 cm (c) 2.6 cm (d) 3.0 cm

5. With jaws closed, the vernier zero lies to the right of main zero and the 3rd vernier mark coincides. LC = 0.01 cm. The zero error is: (a) −0.03 cm (b) +0.03 cm (c) +0.07 cm (d) −0.07 cm

6. An observed reading is 3.25 cm and the zero error is −0.02 cm. The correct reading is: (a) 3.23 cm (b) 3.27 cm (c) 3.25 cm (d) 3.20 cm

7. A screw gauge with LC = 0.01 mm shows MSR = 5 mm and CSR = 27. The reading is: (a) 5.027 mm (b) 5.27 mm (c) 7.7 mm (d) 5.0027 mm

8. With the studs touching, the circular zero is 5 divisions below the reference line. LC = 0.01 mm. The zero error is: (a) −0.05 mm (b) +0.05 mm (c) +0.5 mm (d) −0.95 mm

9. A gauge has 100 circular divisions and LC = 0.01 mm. With the studs touching, the circular zero is above the reference line and the 97th division coincides. The zero error is: (a) +0.97 mm (b) −0.97 mm (c) +0.03 mm (d) −0.03 mm

10. Backlash error in a screw gauge is reduced by: (a) using the ratchet (b) turning the screw in one direction only (c) reading quickly (d) increasing the pitch

11. The ratchet of a screw gauge is used to: (a) remove zero error (b) prevent excess pressure on the object (c) change the pitch (d) lock the scale

12. A tower is seen from two points 100 m apart, with a parallax angle of 0.02 rad. Its distance is: (a) 2 m (b) 500 m (c) 5000 m (d) 2000 m

13. The Moon subtends 0.5° at the Earth and is 3.84 × 10⁸ m away. Its diameter is about: (a) 3.4 × 10⁶ m (b) 1.9 × 10⁸ m (c) 6.4 × 10⁶ m (d) 3.4 × 10⁴ m

14. A film of oleic acid of volume 2 × 10⁻¹⁰ m³ spreads over 0.4 m². The molecular size is about: (a) 8 × 10⁻¹¹ m (b) 5 × 10⁻¹⁰ m (c) 2 × 10⁻⁹ m (d) 5 × 10⁻¹¹ m

15. The inner diameter of a test tube is best measured with: (a) a screw gauge (b) the outside jaws of vernier callipers (c) the inside jaws of vernier callipers (d) a metre scale

16. The most suitable instrument to measure the diameter of a thin wire is: (a) metre scale (b) vernier callipers (c) screw gauge (d) measuring tape

17. The most accurate clocks today use transitions in atoms of: (a) hydrogen (b) caesium (c) krypton (d) quartz

18. Masses of atoms are measured using a: (a) spring balance (b) physical balance (c) mass spectrograph (d) vernier

19. The depth of a small beaker can be found with the vernier's: (a) outside jaws (b) inside jaws (c) depth rod (d) locking screw

20. If n vernier divisions equal (n − 1) main scale divisions of size s each, the least count is: (a) s/(n − 1) (b) s/n (c) ns (d) (n − 1)s/n

21. A screw gauge has 100 circular divisions, and the spindle moves 2.5 mm in 5 full rotations. The least count is: (a) 0.005 mm (b) 0.025 mm (c) 0.05 mm (d) 0.5 mm

22. The precision of an instrument is mainly decided by its: (a) length (b) least count (c) zero error (d) material

23. Assertion (A): A screw gauge is more precise than common vernier callipers. Reason (R): The least count of a common screw gauge is smaller than that of common vernier callipers. (a) Both true, R explains A (b) Both true, R does not explain A (c) A true, R false (d) A false, R true

24. Statement I: A positive zero error is subtracted from the observed reading. Statement II: For a negative zero error, its magnitude is added to the observed reading. (a) Both true (b) Both false (c) I true, II false (d) I false, II true

25. In a vernier, 1 MSD = 1 mm and 50 VSD = 49 MSD. MSR = 1.2 cm and the 22nd vernier mark coincides. The reading is: (a) 1.222 cm (b) 1.244 cm (c) 1.22 cm (d) 1.2044 cm

Answer key with reasons

QAnsReason
1b1 mm / 10.
2b0.5 mm / 20 = 0.025 mm.
3a0.5 / 50 = 0.01 mm.
4b2.4 + 6 × 0.01.
5bRight of zero means positive: 3 × 0.01.
6b3.25 − (−0.02) = 3.27 cm.
7b5 + 27 × 0.01.
8bBelow the line means positive: 5 × 0.01.
9dAbove the line means negative: −(100 − 97) × 0.01.
10bBacklash appears when direction reverses.
11bIt slips once contact is made.
12cD = b/θ = 100/0.02.
13a3.84 × 10⁸ × 8.73 × 10⁻³ ≈ 3.35 × 10⁶ m.
14bV/A = 2 × 10⁻¹⁰ / 0.4.
15cInside jaws fit within the tube.
16cIts LC (0.01 mm) suits thin wires.
17bCaesium-133 defines the second.
18cPath in a magnetic field depends on mass.
19cThe depth rod slides out from the end.
20bLC = s − s(n − 1)/n = s/n.
21aPitch = 0.5 mm; LC = 0.5/100.
22bSmaller LC, finer readings.
23a0.01 mm against 0.1 mm.
24aCorrected = observed − (−e) = observed + e.
25bLC = 1/50 mm = 0.002 cm; 1.2 + 22 × 0.002 = 1.244 cm.

Chapter 2 revision sheet

One-page summary

  • Least count (LC) is the smallest value an instrument can read directly. Smaller LC means a more precise instrument.

  • Typical least counts: metre scale 1 mm, vernier callipers 0.1 mm, screw gauge 0.01 mm, digital stopwatch 0.01 s.

  • Vernier: if n vernier divisions equal (n − 1) main-scale divisions, LC = 1 MSD − 1 VSD = MSD/n.

  • Vernier reading = main-scale reading (MSR) + vernier coincidence (VSC) × LC.

  • Screw gauge: pitch = distance the spindle moves in one full turn. LC = pitch / number of circular divisions.

  • Screw gauge reading = MSR + circular-scale reading (CSR) × LC.

  • Vernier zero to the right of main zero (jaws closed): positive zero error. To the left: negative.

  • Screw gauge: circular zero below the reference line (studs touching): positive zero error. Above: negative.

  • Corrected reading = observed reading − zero error, keeping the sign of the zero error.

  • Zero error is a systematic error: repeating the reading does not remove it.

  • Backlash error: a worn screw turns a little without moving the spindle when you reverse direction. Turn in one direction only.

  • The ratchet lets you close the studs with the same gentle pressure every time.

  • Parallax: distance D = b/θ, where b is the basis and θ the parallax angle in radians. Size of a far object d = Dα.

  • Molecular size: spread a known volume V of oleic acid as a one-molecule film of area A; thickness t = V/A.

  • Atomic masses come from a mass spectrograph (1 u = 1.66 × 10⁻²⁷ kg). Caesium atomic clocks set the time standard.

Must-remember table

ItemFormula or value
Vernier LCMSD/n (n VSD = (n − 1) MSD)
Vernier readingMSR + VSC × LC
Screw gauge LCpitch / circular divisions
Screw gauge readingMSR + CSR × LC
Corrected readingobserved − zero error (with sign)
Parallax distanceD = b/θ
Size from angled = Dα
Film thicknesst = V/A
1°π/180 rad = 1.745 × 10⁻² rad
1′ (arc minute)2.91 × 10⁻⁴ rad
1″ (arc second)4.85 × 10⁻⁶ rad
1 u1.66 × 10⁻²⁷ kg

Memory aids

  • "One minus one": vernier LC = 1 MSD − 1 VSD.

  • "Pitch per piece": screw gauge LC = pitch shared out over the pieces (divisions) of the circular scale.

  • "Right is plus, below is bonus": vernier zero to the Right gives a Plus error; circular zero Below the line gives a positive (bonus) error.

  • "COZ": Corrected = Observed − Zero error. Never add a positive zero error.

  • "Base over angle": D = b/θ. A bigger angle means a nearer object.

Concept connections

  • Physics Book 20: Experimental Skills uses vernier callipers and the screw gauge in the prescribed experiments (diameter of a wire, internal volume of a beaker).

  • Physics Book 7: Properties of Solids and Liquids needs the wire diameter from a screw gauge to find Young's modulus.

  • Physics Book 10: Oscillations and Waves times a pendulum; the stopwatch least count limits the result, which links to Chapter 3 of this book.

Practice MCQs: Chapter 2, new NEET pattern (Q26–40)

26. Match List I (instrument) with List II (typical least count).

List I:

  • A. Metre scale

  • B. Vernier callipers

  • C. Screw gauge

  • D. Digital stopwatch

List II:

  • i. 0.01 mm

  • ii. 1 mm

  • iii. 0.01 s

  • iv. 0.1 mm

(a) A-iv, B-ii, C-i, D-iii (b) A-ii, B-iv, C-i, D-iii (c) A-ii, B-i, C-iv, D-iii (d) A-iii, B-iv, C-i, D-ii

27. Match List I with List II.

List I:

  • A. Positive zero error of a vernier

  • B. Negative zero error of a screw gauge

  • C. Backlash error

  • D. Ratchet

List II:

  • i. Closes the studs with the same light pressure every time

  • ii. Screw turns slightly without moving the spindle when direction is reversed

  • iii. Vernier zero lies to the right of main-scale zero with jaws closed

  • iv. Circular-scale zero lies above the reference line with studs touching

(a) A-iii, B-ii, C-iv, D-i (b) A-iv, B-iii, C-ii, D-i (c) A-i, B-iv, C-ii, D-iii (d) A-iii, B-iv, C-ii, D-i

28. In each vernier below, n VSD coincide with (n − 1) MSD. Match List I with the least count in List II.

List I:

  • A. 1 MSD = 1 mm, 10 VSD = 9 MSD

  • B. 1 MSD = 1 mm, 20 VSD = 19 MSD

  • C. 1 MSD = 0.5 mm, 25 VSD = 24 MSD

  • D. 1 MSD = 0.5 mm, 50 VSD = 49 MSD

List II:

  • i. 0.05 mm

  • ii. 0.01 mm

  • iii. 0.1 mm

  • iv. 0.02 mm

(a) A-i, B-iii, C-iv, D-ii (b) A-iii, B-iv, C-i, D-ii (c) A-iii, B-i, C-iv, D-ii (d) A-ii, B-i, C-iv, D-iii

29. Match the screw gauge in List I with its least count in List II.

List I:

  • A. Pitch 1 mm, 100 circular divisions

  • B. Pitch 0.5 mm, 100 circular divisions

  • C. Pitch 1 mm, 50 circular divisions

  • D. Pitch 0.5 mm, 10 circular divisions

List II:

  • i. 0.02 mm

  • ii. 0.05 mm

  • iii. 0.01 mm

  • iv. 0.005 mm

(a) A-iii, B-iv, C-i, D-ii (b) A-iv, B-iii, C-i, D-ii (c) A-iii, B-iv, C-ii, D-i (d) A-i, B-iv, C-iii, D-ii

30. How many of the following statements are correct?

  • A. If n VSD = (n − 1) MSD, the vernier LC is MSD/n.

  • B. A smaller least count means a more precise instrument.

  • C. Zero error is a random error.

  • D. Backlash error is avoided by turning the screw in one direction only.

  • E. Corrected reading = observed reading + zero error, sign included.

(a) Three (b) Two (c) Four (d) Five

31. Choose the correct set of statements about the parallax method.

  • A. D = b/θ, with θ in radians.

  • B. For the same object, a longer basis gives a larger parallax angle.

  • C. One arc second is about 4.85 × 10⁻⁶ rad.

  • D. For a fixed basis, a farther object gives a larger parallax angle.

(a) A and B only (b) A, C and D only (c) B and D only (d) A, B and C only

32. A screw gauge has pitch 0.5 mm and 50 circular divisions. With the studs touching, the circular zero is 3 divisions below the reference line. For a sheet, MSR = 4.5 mm and CSR = 27. Choose the correct set.

  • A. LC = 0.01 mm

  • B. Zero error = +0.03 mm

  • C. Observed reading = 5.04 mm

  • D. Corrected reading = 4.74 mm

(a) A, B and D only (b) A and C only (c) B, C and D only (d) A, B, C and D

33. How many of the following statements are correct?

  • A. Atomic masses are measured with a mass spectrograph.

  • B. 1 u = 1.66 × 10⁻²⁷ kg.

  • C. Caesium atomic clocks are among the most accurate time standards.

  • D. A common beam balance can weigh a single atom.

  • E. The SI second is defined using a caesium-133 transition frequency.

(a) Two (b) Three (c) Five (d) Four

34. A vernier callipers (LC = 0.1 mm) has a zero error of +0.2 mm. Four students measure the same pencil.

StudentMSR (mm)Vernier division coinciding
P246
Q244
R248
S250

Whose corrected reading is 24.6 mm?

(a) P (b) Q (c) R (d) S

35. For a screw gauge, a graph of observed reading (y-axis) against true thickness (x-axis) is a straight line of slope 1 that cuts the y-axis at −0.04 mm. What is the zero error, and what is the true thickness when the gauge shows 2.36 mm?

(a) +0.04 mm, 2.32 mm (b) −0.04 mm, 2.40 mm (c) −0.04 mm, 2.32 mm (d) +0.04 mm, 2.40 mm

36. The table gives the basis and parallax angle for four far objects.

ObjectBasis b (m)Parallax angle θ (rad)
X20.01
Y100.02
Z50.004
W10.002

Which object is farthest, and how far is it?

(a) Y, 500 m (b) X, 200 m (c) Z, 1250 m (d) W, 500 m

Case for Q37–38: Ravi measures a steel wire for a Young's modulus experiment. His screw gauge has pitch 1 mm and 100 circular divisions. With the studs touching, the circular zero stands 2 divisions above the reference line. On the wire, the main scale shows 1 mm and the circular scale reads 46.

37. The least count and zero error of Ravi's gauge are (a) 0.01 mm, −0.02 mm (b) 0.1 mm, −0.2 mm (c) 0.01 mm, +0.02 mm (d) 0.001 mm, −0.002 mm

38. The corrected diameter of the wire is (a) 1.44 mm (b) 1.46 mm (c) 1.50 mm (d) 1.48 mm

39. A vernier has 1 MSD = 1 mm and n VSD = (n − 1) MSD, with LC = 0.05 mm. With jaws closed, the vernier zero is right of the main zero and the 4th vernier division coincides. For a rod, MSR = 32 mm and the 13th vernier division coincides. The corrected length is (a) 32.85 mm (b) 32.45 mm (c) 32.65 mm (d) 32.25 mm

40. A planet 8.24 × 10¹¹ m from Earth has an angular diameter of 35″. Its diameter is about (a) 2.9 × 10⁸ m (b) 1.4 × 10⁶ m (c) 1.4 × 10⁸ m (d) 8.0 × 10⁹ m

Answer key (Q26–40)

QAnsReason
26bScale 1 mm, vernier 0.1 mm, screw gauge 0.01 mm, stopwatch 0.01 s
27dRight of zero is positive; above the line is negative; backlash and ratchet as described
28cLC = MSD/n: 0.1, 0.05, 0.02, 0.01 mm
29aLC = pitch/divisions: 0.01, 0.005, 0.02, 0.05 mm
30aA, B, D true; zero error is systematic; corrected = observed − zero error
31dFarther object gives a smaller angle, so D is false
32aObserved = 4.5 + 0.27 = 4.77 mm; corrected = 4.77 − 0.03 = 4.74 mm
33dA, B, C, E true; atoms need a mass spectrograph
34cR: 24 + 0.8 − 0.2 = 24.6 mm
35bIntercept = zero error = −0.04 mm; true = 2.36 + 0.04 = 2.40 mm
36cD = b/θ: X 200, Y 500, Z 1250, W 500 m
37aLC = 1/100 = 0.01 mm; above the line gives −2 × 0.01 mm
38d1 + 0.46 − (−0.02) = 1.48 mm
39bn = 20; zero error +0.20 mm; 32.65 − 0.20 = 32.45 mm
40c35″ = 1.70 × 10⁻⁴ rad; d = Dα ≈ 1.4 × 10⁸ m
22 min left
‹
›