Meter Bridge and Potentiometer for JEE
On this page
  1. What this post covers
  2. The meter bridge
  3. The potentiometer
  4. Why the potentiometer beats a voltmeter
  5. Comparing two EMFs
  6. Internal resistance of a cell
  7. Using a standard resistor: ammeter and voltmeter calibration
  8. Sensitivity
  9. What changes the balance point
  10. Question patterns worth recognising
  11. Worked examples
  12. Common traps
  13. A one-page recap
  14. How to practise this chapter
  15. Frequently asked questions
  16. Why is the galvanometer only used to show zero deflection?
  17. Why does the meter bridge work best with the null point near the middle?
  18. Why can a potentiometer measure an EMF but a voltmeter cannot?
  19. How does a potentiometer find internal resistance?
  20. What happens if the driver cell's EMF falls during an experiment?
  21. Do I need to remember end corrections for JEE Main?

The meter bridge and the potentiometer are the two instruments in the current electricity chapter that students are asked to understand, not merely to calculate with. Both are null methods: a galvanometer is used only to show zero deflection, so the quantity being measured is compared with a known quantity without any current being drawn from the circuit under test at the balance point. That one idea explains why the instruments exist, why they are more accurate than a plain ammeter or voltmeter, and why so many JEE-style questions on them are conceptual: what happens to the balance point if the driver cell weakens, if a resistor is shunted, if the key is left closed. The numerical questions are short; the conceptual ones need a clean model.

The current electricity chapter guide introduces both instruments with a worked example for each. This post takes them much further: the exact conditions behind each formula, end corrections, errors and sensitivity, the standard uses of the potentiometer (comparing EMFs, finding internal resistance, calibrating an ammeter), and a set of problem families with the traps that go with each. The neighbouring posts are resistor networks and symmetry methods, Kirchhoff's laws and multi-loop circuits and internal resistance and maximum power transfer. The practical side of measuring instruments is covered in experimental skills in JEE Main Physics. Eleven worked examples follow, each checked by calculation.

What this post covers

Both instruments belong to the JEE Main current electricity syllabus. The families that appear are:

Family The idea behind it
Meter bridge, find an unknown resistance Balance condition of a Wheatstone bridge with a uniform wire
Meter bridge, combinations in a gap Replace series or parallel combinations by one resistance first
Meter bridge, errors and end corrections Relative error in $X$, position of best accuracy, swapping $R$ and $X$
Potentiometer, potential gradient $k=\dfrac{\text{voltage across the wire}}{\text{length}}$
Potentiometer, comparing EMFs $\varepsilon_1/\varepsilon_2=l_1/l_2$, sum and difference method
Potentiometer, internal resistance $r=R\,\dfrac{l_1-l_2}{l_2}$
Potentiometer, ammeter and voltmeter checks Voltage across a standard resistor
Conceptual statements Sensitivity, driver cell changes, why null methods are accurate

In our own JEE Main mocks Current Electricity gets roughly 1.5 of the 25 questions in a physics section; that is our blueprint, not an official weightage.

The meter bridge

A meter bridge is a Wheatstone bridge in which two of the four arms are the two parts of a uniform wire one metre long, stretched along a scale. The two other arms are the resistance box $R$ in one gap and the unknown resistance $X$ in the other gap. A galvanometer connects the junction of $R$ and $X$ to a sliding contact (the jockey) on the wire. The jockey is moved until the galvanometer shows no deflection; the point where this happens is the null point, at a distance $l$ from the end nearer $R$.

The wire is uniform, so the resistance of a length is proportional to the length: the part of length $l$ has resistance $\lambda l$ and the rest has $\lambda(100-l)$, with $\lambda$ the resistance per centimetre. The balance condition of the bridge, $\dfrac RX=\dfrac{\lambda l}{\lambda(100-l)}$, removes $\lambda$ and gives

$X=R\,\dfrac{100-l}{l}$

with $l$ measured in centimetres from the end at which $R$ is connected. You do not need to know the resistance of the wire at all. That is the point of the design: the unknown is compared with the known, and the wire serves only as a ratio arm.

Points worth owning:

  1. Which side is $l$ measured from. Always from the end where the known resistance sits. If you reverse the roles, replace $l$ by $100-l$. Many errors come from using $X=R\,l/(100-l)$ when the diagram has $R$ on the right.
  2. Combinations in a gap. If the gap holds resistors in series or parallel, first replace them by a single equivalent resistance, then apply the formula. The wire does not care what is in the gap.
  3. Why the null point should be near the middle. The relative error in $X$ comes from the error $\delta l$ in locating the null point. Writing $X=R(100-l)/l$ and differentiating, $\dfrac{\delta X}{X}=\dfrac{100\,\delta l}{l(100-l)}$. The denominator $l(100-l)$ is largest at $l=50$, so the fractional error is smallest when the null point is at the middle. In practice one chooses $R$ close to $X$ so that $l$ is near $50$ cm.
  4. End corrections. The wire ends are soldered to thick copper strips whose resistance is not zero. So the effective lengths are $l+\alpha$ and $100-l+\beta$ with small end corrections $\alpha$ and $\beta$. Interchanging $R$ and $X$ and averaging the two measurements reduces the effect. Calibrating with two known resistances and fitting $\alpha$ and $\beta$ is another way to remove it.
  5. Why the current should flow for a short time. If the wire heats, its resistance changes with temperature along its length unevenly, spoiling the proportionality to length. The key is closed briefly while taking a reading.
  6. Why the galvanometer protection matters. A high resistance is kept in series with the galvanometer until the null point is approximately known, to avoid damaging it. This is a practical point that a viva-style question can ask.

Also read: Young's Double Slit Problems in Telugu: JEE ఫ్రింజ్ లెక్కలు

The potentiometer

A potentiometer is a long uniform wire (commonly several metres) carrying a steady current from a driver cell, so that a steady potential gradient exists along the wire. If the driver gives a current $I$ through a wire of resistance $R_w$ and length $L$, the potential difference per unit length is

$k=\dfrac{IR_w}{L}$

When there is a series resistor $R_s$ in the driver circuit (a rheostat) and the driver cell has internal resistance $r_d$, $I=\dfrac{\varepsilon_d}{R_w+R_s+r_d}$ and therefore

$k=\dfrac{\varepsilon_d}{R_w+R_s+r_d}\cdot\dfrac{R_w}{L}$

To measure an EMF $\varepsilon$, connect its positive terminal to the end of the wire where the driver's positive terminal is also attached, and its negative terminal through a galvanometer to the jockey. Move the jockey until the galvanometer reads zero. At that position no current flows through the test cell, so its terminal voltage equals its EMF, and equals the potential difference along the wire between the end and the jockey:

$\varepsilon=k\,l$

Two conditions must hold. First, the driver EMF must exceed the EMF being measured, else no balance exists within the wire. Second, the polarity must agree: the positive of the test cell must go to the higher-potential end of the wire, else the galvanometer deflects the same way everywhere.

Why the potentiometer beats a voltmeter

A voltmeter draws some current from the cell, so it reads the terminal voltage $\varepsilon-Ir$, not the EMF. At the balance point of a potentiometer the test cell supplies no current, so its internal resistance does not enter at all. The potentiometer therefore measures the true EMF. A related statement: the balance length does not depend on the internal resistance of the test cell, nor on the resistance of the galvanometer; the galvanometer's job is only to show zero.

Comparing two EMFs

With the same gradient $k$, two cells balance at $l_1$ and $l_2$ and

$\dfrac{\varepsilon_1}{\varepsilon_2}=\dfrac{l_1}{l_2}$

The gradient cancels, so you do not need to know it, only that it did not change between the two readings. The sum and difference method connects the cells first in series aiding and then in series opposing. With balance lengths $l_s$ for $\varepsilon_1+\varepsilon_2$ and $l_d$ for $\varepsilon_1-\varepsilon_2$:

$\dfrac{\varepsilon_1}{\varepsilon_2}=\dfrac{l_s+l_d}{l_s-l_d}$

This is useful when the two EMFs are nearly equal, because the balance lengths for the sum and difference are then very different, and the measurement of the ratio is far less sensitive to the error in locating the null.

Internal resistance of a cell

Balance the cell on open circuit at length $l_1$; that gives $\varepsilon=kl_1$. Then connect a known resistance $R$ across the cell. It now delivers current $I=\dfrac{\varepsilon}{R+r}$, and its terminal voltage is $V=IR$. Balance again at $l_2$ so that $V=kl_2$. Dividing,

$\dfrac{\varepsilon}{V}=\dfrac{l_1}{l_2}=\dfrac{R+r}{R}$

and so

$r=R\,\dfrac{l_1-l_2}{l_2}$

The result does not require $k$. Notice that $l_2<l_1$ always, because the terminal voltage is lower than the EMF.

Using a standard resistor: ammeter and voltmeter calibration

To measure a current $I$ in a circuit, pass it through a known standard resistor $R_0$ and balance the potential difference $IR_0$ along the wire: $IR_0=kl$, so $I=\dfrac{kl}{R_0}$. Used in this way the potentiometer checks an ammeter. A voltmeter is checked by balancing a known fraction of the voltage it reads, using a potential divider if the voltage is larger than the potentiometer's range.

Sensitivity

A potentiometer is more sensitive when its gradient is smaller. A small gradient means a given change in EMF produces a large change in balance length, so the null point can be located more precisely. The gradient is made smaller by increasing the series resistance in the driver circuit (reducing $I$) or by using a longer wire. A longer wire at the same current has the same gradient but a larger range; if the driver voltage is fixed across a longer wire, the gradient drops. A wise student keeps three words apart: the range is the largest EMF that can be balanced, $kL$; the sensitivity improves as $k$ falls; the accuracy depends on how precisely the null point is read.

What changes the balance point

A common conceptual question asks how the balance length changes when something in the circuit is altered.

Change Effect on gradient $k$ Balance length for the same cell
Driver EMF increases Increases Decreases
Series resistance in the driver circuit increases Decreases Increases
Driver cell weakens (EMF falls) Decreases Increases (may run beyond the wire)
Internal resistance of the test cell increases None None (no current at balance)
Test cell connected with reversed polarity None No balance
Wire replaced by a thicker one of the same length and material $R_w$ falls, $I$ rises or falls depending on the rest Depends: recompute $k=IR_w/L$

For the last row, always recompute the gradient from first principles, because the answer depends on the rest of the driver circuit. If the driver has a large series resistance, $I$ barely changes with $R_w$ and the gradient falls with the resistance of the wire.

Question patterns worth recognising

  1. Straight meter bridge. Known $R$, null at $l$, find $X$.
  2. Gap with a combination. Reduce the combination first.
  3. Shunt across a gap. The new equivalent resistance changes the null point; compute it.
  4. Error analysis. Percentage error in $X$ for a given $\delta l$; where to place the null point.
  5. Gradient from a given circuit. Series resistor and internal resistance of the driver.
  6. Comparing two EMFs, direct and sum-difference.
  7. Internal resistance from two balance lengths.
  8. Current or voltage from a standard resistor.
  9. Statement type (multiple correct) on sensitivity and driver changes.

Worked examples

Every numerical result below was verified by calculation before being written here.

Example 1 (numerical, easy). In a meter bridge the known resistance $R=4\ \Omega$ is in the left gap and the unknown resistance $X$ in the right gap. The null point is at $40$ cm from the left end. Find $X$.

Solution. $X=R\,\dfrac{100-l}{l}=4\times\dfrac{60}{40}=6\ \Omega$. Answer: $6\ \Omega$.

Example 2 (single correct, easy). In a meter bridge the left gap holds a $6\ \Omega$ and a $3\ \Omega$ resistor in parallel, and the right gap holds an $8\ \Omega$ and a $4\ \Omega$ resistor in series. The null point from the left end is at

(A) $12.5$ cm (B) $14.3$ cm (C) $16.7$ cm (D) $20.0$ cm

Solution. Left gap: $\dfrac{6\times3}{9}=2\ \Omega$. Right gap: $8+4=12\ \Omega$. $\dfrac{l}{100-l}=\dfrac{2}{12}$, so $l=\dfrac{100\times2}{14}=14.3$ cm. Answer: (B). Option (C) results from forgetting to add the series resistors correctly ($2/(2+10)$), and (D) from treating both gaps as $2\ \Omega$ and $8\ \Omega$.

Example 3 (numerical, moderate). In the meter bridge of Example 1, a $3\ \Omega$ resistor is connected in parallel with $X$. Find the new null point from the left end, in centimetres to one decimal.

Solution. The right gap is now $\dfrac{6\times3}{9}=2\ \Omega$. The null condition $\dfrac{l}{100-l}=\dfrac{R}{X'}=\dfrac42=2$ gives $l=\dfrac{200}{3}=66.7$ cm. The null point moves from $40$ cm to $66.7$ cm, because the right-hand gap resistance has fallen. Answer: $66.7$ cm.

Example 4 (numerical, moderate). The null point in a meter bridge can be located to within $0.1$ cm. Find the fractional error in $X$ caused by this when the null point is at $50$ cm, and when it is at $20$ cm, in percent to two decimals.

Solution. $\dfrac{\delta X}{X}=\dfrac{100\,\delta l}{l(100-l)}$. At $l=50$: $\dfrac{100\times0.1}{50\times50}=0.004=0.40\%$. At $l=20$: $\dfrac{10}{20\times80}=0.00625=0.63\%$ (to two decimals $0.63\%$). The error is smallest at the middle of the wire. Answers: $0.40\%$ and $0.63\%$. Moving the null point to $10$ cm would give $1.11\%$.

Example 5 (numerical, moderate). A meter bridge with $R=5\ \Omega$ in the left gap has its null point at $45.0$ cm. If the end corrections are $0.5$ cm at each end, find the true value of $X$ and the value you would get by ignoring the corrections, in ohms to two decimals.

Solution. Ignoring corrections: $X=5\times\dfrac{55.0}{45.0}=6.11\ \Omega$. With corrections, the effective lengths are $45.5$ cm and $55.5$ cm, so $X=5\times\dfrac{55.5}{45.5}=6.10\ \Omega$. The difference is about $0.2\%$. Answers: $6.11\ \Omega$ (naive) and $6.10\ \Omega$ (corrected). The small difference is why end corrections matter only for precise work.

Example 6 (numerical, moderate). A potentiometer wire has length $10$ m and resistance $10\ \Omega$. A driver cell of EMF $2$ V with negligible internal resistance is connected in series with the wire and a $10\ \Omega$ resistor. A cell is balanced at $5.4$ m. Find the potential gradient and the EMF of the cell.

Solution. The current is $I=\dfrac{2}{10+10}=0.1$ A. The voltage across the wire is $0.1\times10=1$ V over $10$ m, so $k=0.1$ V m$^{-1}$. The EMF is $\varepsilon=0.1\times5.4=0.54$ V. Answers: $0.1$ V m$^{-1}$ and $0.54$ V.

Example 7 (numerical, moderate). With the potential gradient of Example 6 ($0.1$ V m$^{-1}$), the current in a circuit passes through a standard resistor of $0.5\ \Omega$, and the potential difference across it balances at $4.2$ m. Find the current, and the balance length of a second cell that balances at $7.2$ m in terms of the first cell's EMF ratio.

Solution. The voltage across the standard resistor is $kl=0.1\times4.2=0.42$ V, so $I=\dfrac{0.42}{0.5}=0.84$ A. For two cells on the same gradient, $\dfrac{\varepsilon_1}{\varepsilon_2}=\dfrac{l_1}{l_2}$, so a cell balancing at $5.4$ m and another at $7.2$ m have EMFs in the ratio $\dfrac{5.4}{7.2}=0.75$, that is $0.54$ V and $0.72$ V. Answers: $0.84$ A and a ratio of $0.75$.

Example 8 (numerical, harder). Two cells are connected in series aiding and balanced on a potentiometer at $8.0$ m; connected in series opposing they balance at $2.0$ m. Find the ratio of their EMFs.

Solution. $\dfrac{\varepsilon_1}{\varepsilon_2}=\dfrac{l_s+l_d}{l_s-l_d}=\dfrac{8+2}{8-2}=\dfrac{10}{6}=1.67$. Check: with $k=0.1$ V m$^{-1}$, $\varepsilon_1+\varepsilon_2=0.8$ V and $\varepsilon_1-\varepsilon_2=0.2$ V give $\varepsilon_1=0.5$ V and $\varepsilon_2=0.3$ V, a ratio of $5/3$. Answer: $5/3\approx1.67$.

Example 9 (numerical, harder). The open-circuit balance length of a cell on a potentiometer is $7.5$ m. When a $10\ \Omega$ resistor is connected across it, the balance length becomes $6.0$ m. Find the internal resistance of the cell.

Solution. $r=R\,\dfrac{l_1-l_2}{l_2}=10\times\dfrac{7.5-6.0}{6.0}=2.5\ \Omega$. Check with numbers: if $k=0.2$ V m$^{-1}$, $\varepsilon=1.5$ V and $V=1.2$ V; the current is $V/R=0.12$ A and $r=(1.5-1.2)/0.12=2.5\ \Omega$. Answer: $2.5\ \Omega$.

Example 10 (numerical, harder). A potentiometer wire of length $10$ m and resistance $10\ \Omega$ is in series with a driver cell of EMF $2$ V and internal resistance $1\ \Omega$ and a $4\ \Omega$ resistor. A cell of EMF $1.2$ V is balanced on it. Find the potential gradient and the balance length.

Solution. The total resistance is $10+4+1=15\ \Omega$, so $I=2/15$ A and the voltage across the wire is $\dfrac{2}{15}\times10=\dfrac43$ V over $10$ m, giving $k=0.1333$ V m$^{-1}$. The balance length is $\dfrac{1.2}{0.1333}=9.0$ m. If the driver's internal resistance had been ignored the gradient would have been $0.1429$ V m$^{-1}$ and the answer $8.4$ m, which is the usual error. Answers: $0.133$ V m$^{-1}$ and $9.0$ m.

Example 11 (multiple correct, harder). Which statements about a potentiometer are correct?

(A) A smaller potential gradient makes the potentiometer more sensitive. (B) At balance, the potentiometer measures the EMF of a cell, not its terminal voltage. (C) If the EMF of the driver cell is increased, the balance length for a given cell increases. (D) The balance length does not depend on the internal resistance of the cell being tested.

Solution. (A) True: a smaller gradient means each millivolt shifts the balance by a longer length. (B) True: no current flows in the test cell at balance, so there is no drop across its internal resistance. (C) False: a larger driver EMF raises $k$, so a given EMF balances at a shorter length. (D) True, for the same reason as (B). Answer: A, B, D. An ammeter-voltmeter pair would not satisfy (B) or (D), which is the whole point of the instrument.

Common traps

  1. Measuring $l$ from the wrong end. The formula $X=R(100-l)/l$ presumes $R$ is on the side from which $l$ is measured. If $R$ is on the right, swap the roles, or compute $X=R\,l/(100-l)$.
  2. Not reducing the gap combination. Putting individual resistors into the formula instead of the equivalent of each gap.
  3. Adding the shunt in series. A parallel resistor lowers the gap resistance; a series one raises it. Direction of the null shift follows.
  4. Believing the wire's resistance is needed in a meter bridge. It cancels. If a question gives it, it is a distractor.
  5. Ignoring the driver's internal resistance in the gradient. It is in series with the wire and reduces the current.
  6. Using the potentiometer with a driver EMF below the cell's. No balance point exists within the wire.
  7. Confusing sensitivity with range. A longer wire at a fixed driver voltage across it is more sensitive but not necessarily wider in range; a larger driver voltage widens the range but lowers the sensitivity if the wire length is unchanged.
  8. Applying $r=R(l_1-l_2)/l_2$ with the lengths in the wrong order. $l_1$ is the open-circuit (larger) length.
  9. Assuming the test cell's internal resistance shifts the balance point. It does not, because no current flows in the test cell at balance.
  10. Forgetting that the same gradient is needed across the two readings. Comparing EMFs by $l_1/l_2$ assumes the driver circuit was not altered between measurements. Changing the series resistor between readings invalidates the ratio.
  11. Leaving the key closed. The wire heats; the gradient drifts. Close the key only to take a reading.

A one-page recap

  • Meter bridge: $X=R\dfrac{100-l}{l}$ with $l$ measured from the $R$ end; the wire's resistance cancels.
  • Best accuracy at $l\approx50$ cm: $\dfrac{\delta X}{X}=\dfrac{100\,\delta l}{l(100-l)}$.
  • End corrections reduce by interchanging $R$ and $X$.
  • Potentiometer gradient: $k=\dfrac{IR_w}{L}$, with $I=\dfrac{\varepsilon_d}{R_w+R_s+r_d}$.
  • EMF: $\varepsilon=kl$. Ratio: $\dfrac{\varepsilon_1}{\varepsilon_2}=\dfrac{l_1}{l_2}$. Sum and difference: $\dfrac{l_s+l_d}{l_s-l_d}$.
  • Internal resistance: $r=R\dfrac{l_1-l_2}{l_2}$.
  • Current via standard resistor: $I=\dfrac{kl}{R_0}$.
  • Smaller $k$ means more sensitive; larger $kL$ means wider range.
  • Test cell internal resistance and galvanometer resistance do not affect the balance point.

Also read: JEE Weekly Planning Template in Telugu: వారం ప్లాన్, రివ్యూ

How to practise this chapter

Use the chapter tests in Current Electricity: the first is Current Electricity chapter test 1, continuing at -03-02 to -03-06 (six tests). The chapter is available in the books in English, Hindi and Telugu, and the shelf is at /books/exam/jee. The free JEE Main mini mock is a quick start, and Physics practice test 1 and a full mock such as JEE Main mock 1 test the skill in mixed conditions. Full mocks, practice tests and chapter tests are part of the Pro Pass. For numerical answers see JEE Main numerical value questions. A seven-day plan we suggest:

Day Work
1 Meter bridge derivation from the Wheatstone condition; Examples 1 to 3
2 Errors, end corrections and shunts; Examples 4 and 5; redo with different resistances
3 Potentiometer gradient from circuits with series resistors and internal resistance; Examples 6 and 10
4 Comparing EMFs, direct and sum-difference; Examples 7 and 8
5 Internal resistance and standard-resistor uses; Example 9 and an ammeter check of your own
6 Conceptual statements: the table of "what changes the balance point", Example 11; chapter test 1 timed
7 Chapter test 2, a mixed practice test, and the error log

Frequently asked questions

Why is the galvanometer only used to show zero deflection?

At balance there is no current through it, so its own resistance and sensitivity do not enter the result. This is what makes null methods accurate: the answer depends only on the ratio of two lengths.

Why does the meter bridge work best with the null point near the middle?

The fractional error in $X$ is $100\,\delta l/[l(100-l)]$, and the denominator is largest at $l=50$ cm. So the same error in locating the null produces the smallest error in $X$ at the centre.

Why can a potentiometer measure an EMF but a voltmeter cannot?

A voltmeter draws current, so it reads terminal voltage $\varepsilon-Ir$. At the potentiometer's balance point the test cell supplies no current, so its terminal voltage equals its EMF.

How does a potentiometer find internal resistance?

Balance the cell at length $l_1$ on open circuit and at $l_2$ with a known $R$ across it. Then $r=R(l_1-l_2)/l_2$. The potential gradient cancels, so you need not know it.

What happens if the driver cell's EMF falls during an experiment?

The gradient falls, so every balance length increases and the ratio method, which assumes a fixed gradient between readings, breaks down. This is why a steady driver and a brief key closure are needed.

Do I need to remember end corrections for JEE Main?

Know what they are and how swapping $R$ and $X$ reduces them. Numerical questions rarely require the correction itself, but conceptual statements about the error often do.

Now test yourself: free, no sign-up to start

Share:𝕏fin
Put what you read into practice

Find study material for your next topic

Browse the Reading Room and preview a chapter before choosing what to study.

Browse study material →

Make this reading part of your preparation

Create your free account to bookmark Reading Room chapters and track your practice scores. You’ll return to this article after signing in.

By continuing, you agree to our terms and privacy policy.

No payment needed. Already registered? Use the same options to sign in.