Chapter 6: Electrical Energy and Power
Every electricity bill is a bill for energy, counted in kilowatt hours. In a resistor all of that energy becomes heat, at a rate P = VI.
What you will learn
Derive P = VI and its two other forms.
Use Joule's law of heating and the kilowatt hour.
Pick the right power formula for series and parallel circuits.
Work with rated values of bulbs and heaters.
Explain why power is sent over long distances at high voltage.
6.1 Energy and power in a circuit
When a charge dq moves through a potential difference V, it loses potential energy V dq. In a resistor, the electrons hand this energy to the lattice through collisions. The lattice vibrates harder, and the resistor warms up.
The energy given out in time dt is dW = V dq = VI dt. So the power is:
Using V = IR, the same power can be written in two more ways:
The SI unit is the watt (W), one joule per second.
6.2 Joule's law of heating and the kilowatt hour
For a steady current I through R for time t, the heat produced is:
This is Joule's law of heating. An electric iron, a geyser and an immersion rod all use it.
The joule is too small for household bills. The commercial unit is the kilowatt hour (kWh), often just called a unit:
Note that kW is a unit of power and kWh is a unit of energy.
6.3 Which formula to use
All three forms are correct. Choose the one where the quantity held fixed is visible.
In series, the current is the same. Use P = I²R. Power is proportional to R. The larger resistor gets more power.
In parallel, the voltage is the same. Use P = V²/R. Power is proportional to 1/R. The smaller resistor gets more power.
The brightness of a bulb depends on the power it actually draws, not on its rating.
6.4 Rated values
A bulb marked 100 W, 220 V draws 100 W when connected to exactly 220 V. From the rating you get its resistance, which we take as fixed:
At any other supply voltage V:
So at half the voltage, a bulb draws a quarter of its rated power. For a small fall in voltage, the power falls by twice that percentage. In real bulbs the filament cools at lower voltage, so R changes a little, but NEET questions assume R stays fixed.
6.5 Bulbs in series and in parallel
Take bulbs rated P₁ and P₂ at the same voltage V, so R₁ = V²/P₁ and R₂ = V²/P₂.
In series across V, the total resistance is R₁ + R₂. So the total power is:
In parallel across V, each bulb gets its rated voltage:
| Feature | Bulbs in series | Bulbs in parallel |
|---|---|---|
| Same for each bulb | Current | Voltage |
| Power rule | P ∝ R | P ∝ 1/R |
| Brighter bulb | Lower rated wattage (larger R) | Higher rated wattage (smaller R) |
| Total power, two bulbs at rated V | 1/P = 1/P₁ + 1/P₂ | P = P₁ + P₂ |
| If one fuses | All go off | Others stay on |
This surprises many students. Put a 40 W and a 100 W bulb in series across 220 V, and the 40 W bulb glows brighter.
If series bulbs are put across a higher voltage than they are rated for, check each bulb's share. The bulb with the larger R takes the larger share of voltage and may fuse first.
6.6 Heaters and kettles
A heater coil is just a resistor across a fixed mains voltage. So P = V²/R.
Cutting a coil shorter lowers R and raises the power, as long as the voltage stays the same.
A kettle with two coils that alone boil the water in t₁ and t₂ boils it in t₁ + t₂ with the coils in series, and in t₁t₂/(t₁ + t₂) with them in parallel.
The reason: the heat needed is fixed, H = (V²/R)t, so t ∝ R. Series resistances add, so times add. Parallel conductances add, so reciprocals of times add.
6.7 Power transmission
A power station sends power P along lines of resistance R_line at voltage V. The line current is I = P/V. The power lost as heat in the lines is:
Raising V ten times cuts the loss a hundred times. This is why long-distance lines run at hundreds of kilovolts and step-down transformers near homes bring it to 220 V.
A fuse is a short wire of low melting point placed in series with the circuit. If the current goes above a safe value, I²R heating melts it and breaks the circuit.
Worked example 6.1: A 1000 W iron is used for 2 hours every day for 30 days. Find the energy used and the cost at ₹7 per unit.
Solution: Energy = 1 kW × 2 h × 30 = 60 kWh. Cost = 60 × 7 = ₹420.
Worked example 6.2: A 10 Ω resistor carries 2 A for 5 minutes. Find the heat produced.
Solution: H = I²Rt = 4 × 10 × 300 = 12000 J = 12 kJ.
Worked example 6.3: A bulb is rated 60 W, 220 V. Find its resistance and its rated current.
Solution: R = 220²/60 = 48400/60 ≈ 807 Ω. I = 60/220 ≈ 0.27 A.
Worked example 6.4: A 100 W, 220 V bulb is run on 110 V. What power does it draw?
Solution: P = 100 × (110/220)² = 100/4 = 25 W.
Worked example 6.5: A 40 W and a 100 W bulb, both rated at 220 V, are joined in series across 220 V. Find the power drawn by each and the total.
Solution: R₄₀ = 48400/40 = 1210 Ω and R₁₀₀ = 48400/100 = 484 Ω. I = 220/1694 ≈ 0.130 A. P₄₀ = I² × 1210 ≈ 20.4 W. P₁₀₀ = I² × 484 ≈ 8.2 W. Total ≈ 28.6 W, which matches 1/(1/40 + 1/100). The 40 W bulb is brighter.
Worked example 6.6: One coil of a kettle boils a litre of water in 6 min and another in 12 min. How long with both in series? In parallel?
Solution: Series: 6 + 12 = 18 min. Parallel: (6 × 12)/18 = 4 min.
Worked example 6.7: 100 kW is sent over a line of resistance 0.5 Ω. Compare the line loss at 1000 V and at 10000 V.
Solution: At 1000 V, I = 100 A, loss = 100² × 0.5 = 5000 W, which is 5 per cent. At 10000 V, I = 10 A, loss = 50 W, only 0.05 per cent.
Worked example 6.8: A heater coil is rated 1000 W, 220 V. One-fifth of the coil is cut off and the rest is used on 220 V. Find the new power.
Solution: The new R is 4/5 of the old. P ∝ 1/R at fixed V, so P = 1000 × 5/4 = 1250 W.
Worked example 6.9: The 40 W and 100 W bulbs (220 V rating) of Worked example 6.5 are joined in series across 440 V. Which one fuses?
Solution: The voltage divides in ratio 1210 : 484. The 40 W bulb gets 440 × 1210/1694 ≈ 314 V, well over 220 V, so it fuses. Then the circuit breaks and the 100 W bulb also goes off.
Quick revision
P = VI = I²R = V²/R. H = I²Rt.
1 kWh = 3.6 × 10⁶ J. kW is power, kWh is energy.
Series: P ∝ R. Parallel: P ∝ 1/R.
Rated values give R = V²/P; at voltage V, P = P_rated(V/V_rated)².
Series bulbs: 1/P = 1/P₁ + 1/P₂; lower-watt bulb glows brighter.
Parallel bulbs: P = P₁ + P₂; higher-watt bulb glows brighter.
Kettle coils: series t₁ + t₂; parallel t₁t₂/(t₁ + t₂).
Line loss = P²R/V²; high voltage transmission cuts it.
NEET traps
Assuming the higher-wattage bulb is always brighter. In series it is the dimmer one.
Using P = I²R to say more R means more power in a parallel circuit.
Confusing kW with kWh.
Forgetting to square the voltage ratio when a bulb runs off its rated voltage.
Thinking a shorter heater coil gives less heat. At fixed V it gives more.
Reading high transmission voltage as more loss. Loss falls as 1/V².
Practice MCQs: Chapter 6
Level 1: Concept check
1. One kilowatt hour equals (a) 3.6 × 10³ J (b) 3.6 × 10⁵ J (c) 3.6 × 10⁶ J (d) 3.6 × 10⁸ J
2. The power in a resistor R carrying current I is (a) I²R (b) IR² (c) I/R (d) I²/R
3. The heat produced in a resistor R carrying current I for time t is (a) IRt (b) I²Rt (c) IR²t (d) I²R/t
4. A bulb rated 100 W, 220 V has a resistance of (a) 22 Ω (b) 2.2 Ω (c) 220 Ω (d) 484 Ω
5. Two bulbs are in series across a supply. The bulb with the larger resistance (a) glows brighter (b) glows dimmer (c) glows equally (d) fuses at once
6. The commercial unit of electrical energy is the (a) watt (b) joule (c) kilowatt hour (d) kilowatt
7. A fuse wire should have a (a) high melting point and be in parallel (b) high melting point and be in series (c) low melting point and be in parallel (d) low melting point and be in series
8. Power is sent over long distances at high voltage in order to (a) increase the current (b) reduce the heating loss in the lines (c) increase line resistance (d) make it safer inside homes
9. Two appliances are in parallel on the mains. The one with the smaller resistance draws (a) more power (b) less power (c) the same power (d) no power
10. A 2 kW heater used for 3 hours consumes (a) 0.67 kWh (b) 1.5 kWh (c) 6 kWh (d) 60 kWh
Level 2: NEET standard
11. A 100 W, 220 V bulb is run on 110 V. It draws (a) 50 W (b) 25 W (c) 100 W (d) 12.5 W
12. A 60 W and a 40 W bulb, both rated at the same voltage V, are in series across V. The total power is (a) 100 W (b) 50 W (c) 20 W (d) 24 W
13. The same two bulbs as in Q12 are put in parallel across V. The total power is (a) 24 W (b) 50 W (c) 100 W (d) 2400 W
14. A 25 W and a 100 W bulb, both rated 220 V, are in series across 220 V. Which glows brighter? (a) The 25 W bulb (b) The 100 W bulb (c) Both equally (d) Neither glows
15. A 1000 W, 220 V heater coil is cut to half its length and used on 220 V. Its power is (a) 500 W (b) 2000 W (c) 1000 W (d) 4000 W
16. Coil A of a kettle boils some water in 10 min and coil B in 15 min. With both in parallel, the time is (a) 25 min (b) 12.5 min (c) 5 min (d) 6 min
17. With the two coils of Q16 in series, the time is (a) 25 min (b) 6 min (c) 12.5 min (d) 15 min
18. The mains voltage falls by 2 per cent. The power of a heater of fixed resistance falls by about (a) 2 per cent (b) 1 per cent (c) 4 per cent (d) 8 per cent
19. A 5 Ω resistor gives off heat at 20 W. The current in it is (a) 4 A (b) 2 A (c) 1 A (d) 10 A
20. A 1 kW appliance runs 5 hours a day for 30 days. At ₹6 per unit, the bill is (a) ₹900 (b) ₹150 (c) ₹180 (d) ₹9000
21. Three equal resistors in series across V give total power P. The same three in parallel across V give (a) P/3 (b) 3P (c) P/9 (d) 9P
22. The rated current of an 1100 W, 220 V iron is (a) 0.2 A (b) 2.5 A (c) 5 A (d) 10 A
Level 3: Challenge
23. 200 kW is sent at 20 kV over lines of total resistance 0.4 Ω. The power lost in the lines is (a) 40 W (b) 400 W (c) 4 W (d) 4 kW
24. Bulbs A and B are in series, and bulb C is in parallel with this pair. All three are identical and the group is across V. The ratio of powers P_A : P_C is (a) 1 : 2 (b) 2 : 1 (c) 4 : 1 (d) 1 : 4
25. A 40 W and a 100 W bulb, both rated 220 V, are joined in series across 440 V. Then (a) the 100 W bulb fuses (b) the 40 W bulb fuses (c) both fuse together (d) neither fuses
26. A wire across a fixed voltage is stretched to twice its length (volume fixed) and put back across the same voltage. Its power becomes (a) four times (b) twice (c) one-fourth (d) half
27. A 1000 W heater and a 500 W heater, both rated 220 V, are joined in series across 220 V. The total power is about (a) 1500 W (b) 750 W (c) 500 W (d) 333 W
28. Wires A and B of the same metal and length have diameters in the ratio 1 : 2. They are joined in parallel across a supply. The ratio of power P_A : P_B is (a) 1 : 4 (b) 4 : 1 (c) 1 : 2 (d) 2 : 1
29. Assertion (A): When a 40 W and a 100 W bulb of the same rated voltage are in series, the 40 W bulb glows brighter. Reason (R): In series, power is proportional to resistance, and the 40 W bulb has the larger resistance. (a) Both true, R explains A (b) Both true, R does not explain A (c) A true, R false (d) A false, R true
30. Statement I: A heater coil that is shortened draws less power from the same mains supply. Statement II: For a fixed power sent, raising the transmission voltage increases the loss in the lines. (a) Both true (b) Both false (c) I true, II false (d) I false, II true
Answer key with reasons
| Q | Ans | Reason |
|---|---|---|
| 1 | c | 1000 × 3600 J |
| 2 | a | P = VI with V = IR |
| 3 | b | Joule's law |
| 4 | d | 220²/100 |
| 5 | a | Same I, P ∝ R |
| 6 | c | The "unit" on bills |
| 7 | d | Melts quickly, breaks the series path |
| 8 | b | Loss = P²R/V² |
| 9 | a | Same V, P ∝ 1/R |
| 10 | c | 2 × 3 |
| 11 | b | (1/2)² × 100 |
| 12 | d | 1/(1/60 + 1/40) = 24 W |
| 13 | c | 60 + 40 |
| 14 | a | Larger R in series |
| 15 | b | R halves at fixed V |
| 16 | d | 150/25 |
| 17 | a | 10 + 15 |
| 18 | c | P ∝ V², so twice the percentage |
| 19 | b | I² = 20/5 |
| 20 | a | 150 kWh × ₹6 |
| 21 | d | R_eq goes from 3R to R/3 |
| 22 | c | 1100/220 |
| 23 | a | I = 10 A, 100 × 0.4 |
| 24 | d | A gets V/2, C gets V |
| 25 | b | 40 W bulb gets about 314 V |
| 26 | c | R becomes 4R |
| 27 | d | 1/(1/1000 + 1/500) |
| 28 | a | R ∝ 1/d²; parallel P ∝ 1/R |
| 29 | a | R correctly explains A |
| 30 | b | Shorter coil draws more; higher V cuts loss |
Chapter 6 revision sheet
One-page summary
Electrical energy W = VIt. Power P = VI = I²R = V²/R.
Joule heating: H = I²Rt. It does not depend on the direction of current.
Commercial unit: 1 kWh = 1 unit = 3.6 × 10⁶ J. Units used = (watts × hours)/1000.
Rated values (V_r, P_r) give the resistance: R = V_r²/P_r.
At a different supply voltage V, the actual power is P = P_r(V/V_r)², assuming R stays fixed.
Bulbs in series carry the same current, so P ∝ R: the lower-wattage bulb glows brighter.
Bulbs in parallel share the same voltage, so P ∝ 1/R: the higher-wattage bulb glows brighter.
Rated bulbs in series on the rated voltage: 1/P_total = 1/P_1 + 1/P_2. In parallel: P_total = P_1 + P_2.
Two heater coils boiling the same water: series t = t_1 + t_2; parallel 1/t = 1/t_1 + 1/t_2.
For a fixed V, a lower-resistance heater gives more heat per second.
Transmission loss: I = P/V, loss = P²R/V², so power is sent at high voltage.
A fuse is a short wire of low melting point (tin–lead) in series with the live wire. Choose the smallest rating above the normal current.
Heat used to warm water: Pt = mcΔT (if no loss).
Must-remember table
| Rated device (220 V) | Resistance | Rated current |
|---|---|---|
| 25 W bulb | 1936 Ω | 0.114 A |
| 40 W tube or bulb | 1210 Ω | 0.182 A |
| 60 W bulb | 807 Ω | 0.273 A |
| 100 W bulb | 484 Ω | 0.455 A |
| 1000 W iron | 48.4 Ω | 4.55 A |
| 1100 W heater | 44 Ω | 5 A |
Memory aids
"Series Smaller Shines": in series, the smaller-wattage bulb shines brighter.
"Parallel Prefers Power": in parallel, the higher-wattage bulb shines brighter.
"Series Sums time, Parallel Parts time": heater coils in series add their boiling times; in parallel the times combine like parallel resistors.
"3.6 million per unit": 1 kWh = 3.6 × 10⁶ J.
Concept connections
Heat given to water (mcΔT) and heat flow come from Physics Book 8: Thermodynamics.
Work and power as rates of energy transfer were first met in Physics Book 4: Work, Energy and Power.
High-voltage transmission uses transformers, covered in Physics Book 14: Electromagnetic Induction and Alternating Currents.
Practice MCQs: Chapter 6, Level 4 (new NEET pattern)
31. A bulb is rated 220 V, 100 W. Match List I with List II.
List I: A. Its resistance; B. Its rated current; C. Its power on a 110 V supply; D. Energy it uses in 10 hours at rated voltage
List II: (i) 484 Ω; (ii) 1 kWh; (iii) 25 W; (iv) 0.45 A
(a) A-i, B-iv, C-iii, D-ii (b) A-iv, B-i, C-iii, D-ii (c) A-i, B-iii, C-iv, D-ii (d) A-ii, B-iv, C-iii, D-i
32. Match the quantity in List I with its expression in List II.
List I: A. Power in terms of I and R; B. Power in terms of V and R; C. Heat produced in time t; D. Units (kWh) used by a P-watt device in t hours
List II: (i) Pt/1000; (ii) V²/R; (iii) I²Rt; (iv) I²R
(a) A-ii, B-iv, C-iii, D-i (b) A-iv, B-iii, C-ii, D-i (c) A-iv, B-ii, C-i, D-iii (d) A-iv, B-ii, C-iii, D-i
33. On a fixed supply, coil 1 alone boils a kettle of water in 10 min and coil 2 alone in 15 min. Match the arrangement in List I with the boiling time in List II.
List I: A. Coil 1 alone; B. Both coils in series; C. Both coils in parallel; D. Coil 2 alone at half the supply voltage
List II: (i) 6 min; (ii) 60 min; (iii) 10 min; (iv) 25 min
(a) A-iv, B-iii, C-i, D-ii (b) A-iii, B-i, C-iv, D-ii (c) A-iii, B-iv, C-i, D-ii (d) A-iii, B-iv, C-ii, D-i
34. A 40 W and a 100 W bulb, both rated for 220 V, are used on a 220 V supply. Match List I with List II.
List I: A. Brighter bulb when they are in parallel; B. Brighter bulb when they are in series; C. Ratio R_40 : R_100; D. Ratio of currents I_40 : I_100 in parallel
List II: (i) 2 : 5; (ii) the 100 W bulb; (iii) 5 : 2; (iv) the 40 W bulb
(a) A-iv, B-ii, C-iii, D-i (b) A-ii, B-iv, C-i, D-iii (c) A-ii, B-iii, C-iv, D-i (d) A-ii, B-iv, C-iii, D-i
35. How many of the following statements are correct?
A. 1 kWh = 3.6 × 10⁶ J.
B. A fuse wire has a low melting point and is connected in series with the live wire.
C. The heating effect of current does not depend on the direction of current.
D. On a fixed voltage, a heater of lower resistance produces more heat per second.
E. In series, the bulb with the higher rated wattage glows brighter.
(a) 2 (b) 3 (c) 4 (d) 5
36. Power P is sent at voltage V through a line of resistance R. Choose the correct set of statements.
A. The current in the line is P/V.
B. The power lost in the line is P²R/V².
C. Raising V reduces the loss.
D. The power lost does not depend on V.
(a) A and D only (b) A, B and C only (c) B and D only (d) C and D only
37. A resistor wire is kept on a fixed voltage. Its length is doubled with the same cross-section. Choose the correct set of statements.
A. The power halves.
B. The current halves.
C. The power doubles.
D. The heat produced in a given time doubles.
(a) A and B only (b) C and D only (c) B and C only (d) A, B and D only
38. A flat uses a 1.5 kW geyser for 2 h a day and four 40 W tube lights for 6 h a day, for 30 days, at Rs 6 per unit on a 220 V supply. How many statements are correct?
A. The geyser uses 90 units in the month.
B. The tube lights use 28.8 units in the month.
C. The monthly bill is Rs 540.
D. The geyser draws about 15 A.
(a) 1 (b) 2 (c) 3 (d) 4
39. The graph of power P (y-axis) against current I (x-axis) for a fixed resistor is a parabola through the origin that passes through (2 A, 20 W). The resistance and the power at 3 A are
(a) 10 Ω, 90 W (b) 5 Ω, 30 W (c) 2.5 Ω, 22.5 W (d) 5 Ω, 45 W
40. A room on a 220 V line has these appliances, all switched on together. The smallest fuse from 5 A, 10 A, 15 A and 30 A that will not blow is
| Appliance | Power (W) |
|---|---|
| Fan | 60 |
| TV | 100 |
| Iron | 1000 |
| Kettle | 1100 |
(a) 5 A (b) 10 A (c) 15 A (d) 30 A
41. Two resistors P and Q are connected in parallel across the same supply. Their graphs of heat H (y-axis) against time t (x-axis) are straight lines with slopes 50 J/s for P and 25 J/s for Q. The ratio R_P : R_Q, and the ratio of heat rates H_P : H_Q if the same two are put in series across the supply, are
(a) 2 : 1 and 2 : 1 (b) 1 : 2 and 1 : 2 (c) 1 : 2 and 2 : 1 (d) 2 : 1 and 1 : 2
Passage for Q42–Q43: A 1000 W, 220 V immersion rod heats 2 kg of bathing water in a bucket. Take c = 4200 J kg⁻¹ K⁻¹, ignore heat loss, and treat the rod's resistance as fixed.
42. Time to heat the water from 25 °C to 85 °C at 220 V is
(a) 504 s (b) 252 s (c) 1008 s (d) 840 s
43. On a monsoon evening the supply falls to 198 V. The rod's power is now
(a) 900 W (b) 1000 W (c) 729 W (d) 810 W
44. Three identical bulbs are connected so that bulb A is in series with a parallel pair B and C, across a supply. The ratio of powers P_A : P_B is
(a) 4 : 1 (b) 2 : 1 (c) 1 : 4 (d) 1 : 2
45. A 100 W bulb and a 25 W bulb, both rated 220 V, are connected in series across 440 V. What happens?
(a) The 100 W bulb fuses (b) Both glow normally (c) The 25 W bulb fuses (d) Both fuse at the same moment
Level 4 answer key
| Q | Ans | Reason |
|---|---|---|
| 31 | a | 220²/100 = 484 Ω; 100/220 = 0.45 A; P ∝ V² gives 25 W; 100 W × 10 h = 1 kWh |
| 32 | d | I²R, V²/R, I²Rt, Pt/1000 |
| 33 | c | Series 10 + 15 = 25 min; parallel 150/25 = 6 min; half V gives quarter power, 4 × 15 = 60 min |
| 34 | d | R = V²/P gives 5 : 2; in parallel I ∝ P gives 2 : 5 |
| 35 | c | A to D are correct; in series the lower-wattage bulb is brighter |
| 36 | b | Loss = I²R = P²R/V², so it falls as V rises |
| 37 | a | R doubles, so I = V/R and P = V²/R both halve |
| 38 | b | 90 + 28.8 = 118.8 units costs Rs 712.80; geyser current 1500/220 = 6.8 A. Only A and B are correct |
| 39 | d | 20 = 4R gives 5 Ω; 9 × 5 = 45 W |
| 40 | c | Total 2260 W, I = 10.3 A, so 15 A is the smallest safe fuse |
| 41 | b | Parallel: P ∝ 1/R so R_P : R_Q = 1 : 2; series: P ∝ R so 1 : 2 |
| 42 | a | 2 × 4200 × 60 = 504 000 J, so 504 s |
| 43 | d | 1000 × (198/220)² = 1000 × 0.81 = 810 W |
| 44 | a | A carries I, B carries I/2, so P_A : P_B = I² : (I/2)² = 4 : 1 |
| 45 | c | R = 484 and 1936 Ω; I = 440/2420 A; the 25 W bulb gets 352 V, far above 220 V |