Chapter 8: AC Generator and Transformer
What you will learn
How an AC generator turns rotation into an alternating emf, and the result e = NBAω sin ωt.
Where the coil is when the emf is largest and when it is zero.
How a transformer steps voltage up or down, and the turns-ratio relations.
Transformer efficiency and the four main energy losses, with the cure for each.
Why power is sent over long lines at very high voltage.
8.1 The AC generator
An AC generator (alternator) uses Faraday's law with a changing angle. A coil turns in a magnetic field, so the flux through it keeps changing, and an emf appears.
Main parts
Armature: a coil of N turns, each of area A, wound on a soft-iron core.
Field magnets: strong permanent magnets or electromagnets that give a uniform field B.
Slip rings: two metal rings fixed to the shaft, one joined to each end of the coil. They turn with the coil.
Brushes: carbon blocks pressing on the slip rings. They connect the turning coil to the fixed outside circuit without twisting the leads.

Each end of the turning coil is joined to its own slip ring, and fixed brushes pass the alternating emf to the load without twisting the leads.
A turbine (driven by falling water, steam or wind) rotates the coil with a steady angular speed ω.
The emf. Let the normal to the coil make angle θ = ωt with B, starting at t = 0 with the normal along B. The flux through each turn is BA cos ωt. By Faraday's law:
| Position of coil | Angle of normal with B | Flux | Emf |
|---|---|---|---|
| Plane perpendicular to B | 0° or 180° | Maximum (magnitude) | Zero |
| Plane parallel to B | 90° or 270° | Zero | Maximum, e0 |
When the flux is largest, it is momentarily not changing, so the emf is zero. When the flux is passing through zero, it is changing fastest, so the emf is largest. Flux and emf are 90° out of phase.
The frequency of the emf equals the rotation frequency of the coil. Doubling the speed doubles both e0 and f. Commercial generators in India give 50 Hz. Large ones keep the coil fixed and rotate the magnets instead, but the physics is the same.
8.2 The transformer
A transformer changes an AC voltage to a higher or lower value. It works on mutual induction.
Construction. Two coils, the primary (Np turns, connected to the supply) and the secondary (Ns turns, connected to the load), are wound on the same soft-iron core. The core is built from thin insulated sheets (laminations). It guides almost all the flux of the primary through the secondary.

The core carries one alternating flux through both windings, so each turn gets the same emf and the voltages divide in the ratio of the turns.
Working. The alternating current in the primary sets up an alternating flux Φ in the core. In an ideal transformer, the same flux passes through every turn of both coils. Each turn therefore has the same emf, dΦ/dt. So:
(Ideal: primary resistance negligible so Vp = ep; secondary on open circuit or small current so Vs = es.)
In an ideal transformer no power is lost: VpIp = VsIs. So:
| Type | Turns | Voltage | Current |
|---|---|---|---|
| Step-up | Ns greater than Np | Raised | Lowered by the same factor |
| Step-down | Ns less than Np | Lowered | Raised by the same factor |
A transformer never raises power. What it gains in voltage it gives up in current. It does not work on steady DC, because steady current gives constant flux and no induced emf. It also does not change the frequency.
8.3 Efficiency and energy losses
Large transformers reach 95 to 99% efficiency. The small losses come from four sources.
| Loss | Cause | How it is reduced |
|---|---|---|
| Copper (Joule) loss | I²R heating in the windings | Thick copper wire of low resistance |
| Eddy current loss | Currents induced in the iron core | Laminated core of thin insulated sheets |
| Hysteresis loss | Energy lost in repeated magnetising of the core | Soft iron (narrow hysteresis loop) |
| Flux leakage | Some primary flux misses the secondary | Wind the coils one over the other on a well-designed core |
The hum you hear near a pole transformer comes from the core sheets vibrating at twice the mains frequency. This vibration also wastes a little energy.
8.4 Long-distance transmission
Power P is sent at voltage V, so the line current is I = P/V. If the line resistance is R, the heat lost is:
Raising V by a factor k cuts the loss by k². So power stations step the voltage up to hundreds of kilovolts, send it across the country, then step it down in stages to 220 V for homes. This is the main reason we use AC: transformers make the voltage change easy and efficient.
Worked example 8.1: A generator coil has 100 turns of area 0.05 m² and turns at 50 revolutions per second in a 0.2 T field. Find the peak and rms emf.
Solution: ω = 2π × 50 = 100π rad/s. e0 = NBAω = 100 × 0.2 × 0.05 × 100π = 314 V. erms = 314/√2 = 222 V.
Worked example 8.2: A generator has e0 = 200 V. Find the emf at the instant the plane of the coil makes 60° with the field.
Solution: The plane is at 60°, so the normal is at 30° to B. e = e0 sin 30° = 100 V. Using sin 60° here is the classic slip.
Worked example 8.3: A transformer steps 220 V down to 11 V. The primary has 2000 turns. How many turns does the secondary have?
Solution: Ns = Np × Vs/Vp = 2000 × 11/220 = 100 turns.
Worked example 8.4: An ideal transformer has Np : Ns = 1 : 20. The primary is on 220 V and draws 10 A. Find the secondary voltage and current.
Solution: Vs = 220 × 20 = 4400 V. Is = 10/20 = 0.5 A. Check: 220 × 10 = 4400 × 0.5 = 2200 W.
Worked example 8.5: A transformer of 90% efficiency steps 220 V down to 22 V and supplies 5 A to a load. Find the primary current.
Solution: Output = 22 × 5 = 110 W. Input = 110/0.9 = 122 W. Ip = 122/220 = 0.56 A. An ideal transformer would need only 0.5 A.
Worked example 8.6: A station sends 100 kW through lines of total resistance 0.5 Ω. Find the line loss when the voltage is (i) 1 kV (ii) 20 kV.
Solution: (i) I = 100 A; loss = 100² × 0.5 = 5000 W, which is 5% of the power. (ii) I = 5 A; loss = 25 × 0.5 = 12.5 W. Raising V twenty times cuts the loss 400 times.
Worked example 8.7: A bicycle dynamo gives a peak emf of 6 V at a certain speed. The rider doubles the speed. What happens to the peak emf and the frequency?
Solution: Both e0 = NBAω and f = ω/2π are proportional to ω. Peak emf becomes 12 V and the frequency doubles.
Worked example 8.8 (NEET-hard): A rectangular coil of 50 turns, 20 cm × 10 cm, rotates at 1500 rpm in a 0.5 T field. It feeds a 50 Ω resistor (coil resistance negligible). Find the peak emf, peak current and average power.
Solution: A = 0.02 m². ω = 2π × 1500/60 = 50π rad/s. e0 = 50 × 0.5 × 0.02 × 50π = 78.5 V. I0 = 78.5/50 = 1.57 A. P = e0I0/2 = 61.7 W.
Quick revision
Generator: e = NBAω sin ωt; e0 = NBAω; frequency = rotation frequency.
Emf is largest when the coil's plane is parallel to B, zero when perpendicular.
Slip rings and brushes connect the rotating coil to the external circuit.
Transformer: Vs/Vp = Ns/Np = Ip/Is (ideal). Works only on AC; frequency unchanged.
Efficiency η = output/input. Losses: copper, eddy, hysteresis, flux leakage.
Line loss = P²R/V²; high-voltage transmission cuts it.
NEET traps
Using the angle between the coil's plane and B in e0 sin θ. θ is measured from the normal.
Thinking a step-up transformer raises power. It raises voltage and lowers current.
Writing Is/Ip = Ns/Np. Current goes in the inverse ratio of turns.
Thinking the number of turns affects the generator's frequency. Only rotation speed does.
Using a transformer on DC. Steady current gives no output.
Forgetting that efficiency less than 100% makes the primary current larger than the ideal value.
Practice MCQs: Chapter 8
Level 1: Concept check
1. An AC generator works on the principle of (a) the magnetic effect of current (b) the heating effect of current (c) electromagnetic induction (d) electrostatic induction
2. A transformer works on the principle of (a) mutual induction (b) the magnetic force on a moving charge (c) electrostatic induction (d) the heating effect of current
3. A transformer cannot be used to step up the voltage of (a) a 50 Hz supply (b) a 1 kHz supply (c) any AC supply (d) a steady DC supply
4. In a step-up transformer (a) Ns is less than Np (b) Ns is greater than Np (c) Ns equals Np (d) Vs is less than Vp
5. The core of a transformer is laminated to reduce (a) copper loss (b) flux leakage (c) hysteresis loss (d) eddy current loss
6. The peak emf of an AC generator with N turns of area A rotating at ω in field B is (a) NBA/ω (b) BAω (c) NBAω (d) NBAω/√2
7. The emf of an AC generator is largest when the plane of the coil is (a) parallel to the field (b) perpendicular to the field (c) at 45° to the field (d) at 60° to the field
8. For an ideal transformer, which relation is correct? (a) Vs/Vp = Np/Ns (b) Vs/Vp = Ns/Np = Ip/Is (c) Is/Ip = Ns/Np (d) VsIs is greater than VpIp
9. In an AC generator, the slip rings and brushes are used to (a) convert AC into DC (b) increase the emf (c) reduce friction on the shaft (d) connect the rotating coil to the outside circuit without twisting the leads
10. Hysteresis loss in a transformer is reduced by using (a) thick copper wire (b) a laminated core (c) a soft-iron core (d) high-resistance windings
Level 2: NEET standard
11. A 100-turn coil of area 0.05 m² turns at 50 rev/s in a 0.2 T field. The peak emf is about (a) 157 V (b) 314 V (c) 222 V (d) 628 V
12. A transformer steps 220 V down to 11 V. If the primary has 2000 turns, the secondary has (a) 100 turns (b) 40000 turns (c) 200 turns (d) 50 turns
13. An ideal transformer with Np : Ns = 1 : 20 draws 10 A in the primary. The secondary current is (a) 200 A (b) 5 A (c) 0.5 A (d) 2 A
14. A transformer of 80% efficiency runs on 220 V and delivers 40 W to a load. The primary current is about (a) 0.18 A (b) 4 A (c) 0.5 A (d) 0.23 A
15. The speed of rotation of a generator coil is doubled. The peak emf and the frequency (a) both double (b) stay the same (c) double and stay the same respectively (d) stay the same and double respectively
16. A generator has a peak emf of 200 V. At the instant the plane of the coil makes 60° with the field, the emf is (a) 173 V (b) 200 V (c) 100 V (d) zero
17. A station sends 100 kW at 20 kV through lines of total resistance 0.5 Ω. The line loss is (a) 5 kW (b) 12.5 W (c) 250 W (d) 25 W
18. An ideal transformer steps 220 V down to 22 V. The secondary current is 5 A. The primary current is (a) 50 A (b) 5 A (c) 0.05 A (d) 0.5 A
19. A 200-turn coil of area 0.01 m² rotates at 100 rad/s in a 0.5 T field. The rms emf is about (a) 70.7 V (b) 100 V (c) 141 V (d) 50 V
20. Which loss in a transformer is reduced by using thick copper windings? (a) Eddy current loss (b) Hysteresis loss (c) Copper (Joule) loss (d) Flux leakage
21. An ideal step-up transformer gives 11 kV from 220 V. The primary has 100 turns. The secondary has (a) 500 turns (b) 2000 turns (c) 50 turns (d) 5000 turns
22. At the instant the flux through a generator coil is maximum, the emf is (a) zero (b) maximum (c) half the maximum (d) e0/√2
Level 3: Challenge
23. A rectangular coil of 50 turns, 20 cm × 10 cm, rotates at 1500 rpm in a 0.5 T field. Its peak emf is about (a) 39.3 V (b) 157 V (c) 78.5 V (d) 55.5 V
24. The coil of Q23 feeds a 50 Ω resistor (coil resistance negligible). The average power is about (a) 123 W (b) 61.7 W (c) 30.8 W (d) 78.5 W
25. The same power is sent through the same line first at 1 kV, then at 20 kV. The ratio of line losses (1 kV : 20 kV) is (a) 20 : 1 (b) 1 : 400 (c) 1 : 20 (d) 400 : 1
26. A transformer of 90% efficiency has its primary on 220 V drawing 2 A. The secondary voltage is 1100 V. The secondary current is (a) 0.36 A (b) 0.4 A (c) 0.44 A (d) 10 A
27. The flux through each turn of a 50-turn generator coil is Φ = 0.02 cos(100πt) Wb. The peak emf is about (a) 100 V (b) 314 V (c) 157 V (d) 31.4 V
28. The primary of a transformer is connected to a 12 V battery. After the switch is closed and the current has become steady, the secondary voltage is (a) (Ns/Np) × 12 V (b) 12 V (c) zero (d) very large
29. Assertion (A): An ideal step-up transformer increases the power delivered to the load. Reason (R): In an ideal step-up transformer, the secondary current is smaller than the primary current. (a) Both true, R explains A (b) Both true, R does not explain A (c) A true, R false (d) A false, R true
30. Statement I: The emf of an AC generator is maximum when the plane of the coil is parallel to the magnetic field. Statement II: The frequency of the emf of an AC generator depends on the number of turns in the coil. (a) Both true (b) Both false (c) I true, II false (d) I false, II true
Answer key with reasons
| Q | Ans | Reason |
|---|---|---|
| 1 | c | Rotating coil has changing flux |
| 2 | a | Changing primary flux links secondary |
| 3 | d | Steady DC gives constant flux |
| 4 | b | More secondary turns raise voltage |
| 5 | d | Insulated sheets break eddy paths |
| 6 | c | e0 = NBAω |
| 7 | a | Normal at 90°, flux changing fastest |
| 8 | b | Turns ratio and power balance |
| 9 | d | Rings turn with the coil, brushes stay fixed |
| 10 | c | Soft iron has a narrow hysteresis loop |
| 11 | b | 100 × 0.2 × 0.05 × 100π = 314 V |
| 12 | a | 2000 × 11/220 |
| 13 | c | Is = Ip × Np/Ns = 10/20 |
| 14 | d | Input = 40/0.8 = 50 W; 50/220 |
| 15 | a | e0 and f both ∝ ω |
| 16 | c | Normal at 30°; 200 sin 30° |
| 17 | b | I = 5 A; 25 × 0.5 |
| 18 | d | Ip = 5 × 22/220 |
| 19 | a | e0 = 200 × 0.5 × 0.01 × 100 = 100 V; divide by √2 |
| 20 | c | Low resistance cuts I²R |
| 21 | d | 100 × 11000/220 |
| 22 | a | Flux is momentarily constant at its peak |
| 23 | c | ω = 50π; 50 × 0.5 × 0.02 × 50π |
| 24 | b | e0²/(2R) = 78.5²/100 |
| 25 | d | Loss ∝ 1/V² |
| 26 | a | Output = 0.9 × 440 = 396 W; 396/1100 |
| 27 | b | NΦ0ω = 50 × 0.02 × 100π |
| 28 | c | Constant flux induces nothing |
| 29 | d | Power cannot rise; R is true |
| 30 | c | Frequency depends only on rotation speed |
Chapter 8 revision sheet
One-page summary
AC generator: a coil rotates in a magnetic field, so the angle between B and its normal changes; it turns mechanical energy into electrical energy.
Parts: armature coil, field magnet, two slip rings (one fixed to each end of the coil) and carbon brushes.
Flux per turn Φ = BA cos ωt, so the emf is e = NBAω sin ωt; peak e0 = NBAω.
emf is maximum when the plane of the coil is parallel to B (flux zero) and zero when the plane is perpendicular to B (flux maximum).
Frequency of the emf equals the rotation frequency of the coil. e0 depends on area, not on the coil's shape.
Transformer: works on mutual induction; it needs a changing (AC) current. It does not work on steady DC.
Ideal transformer: Vs/Vp = Ns/Np = Ip/Is. Step-up: Ns > Np, voltage up and current down.
A transformer does not change frequency, and an ideal one does not change power: Vp Ip = Vs Is.
Efficiency η = output power/input power; large transformers reach about 95–99%.
Losses and remedies: copper loss (thick wire), eddy current loss (laminated core), hysteresis loss (soft iron core), flux leakage (windings on top of each other), humming (vibration of laminations).
Transmission: P = VI, line loss = I²R = P²R/V². Raising V by 10 times cuts loss by 100 times.
Power is sent at very high voltage and stepped down near homes to 220 V.
Must-remember table
| Quantity | Formula | Note |
|---|---|---|
| Generator emf | NBAω sin ωt | ω = 2π × rev/s |
| Peak emf | e0 = NBAω | rms = e0/√2 |
| Voltage ratio | Vs/Vp = Ns/Np | ideal |
| Current ratio | Is/Ip = Np/Ns | ideal |
| Efficiency | Pout/Pin | below 100% in practice |
| Line loss | I²R = P²R/V² | falls as 1/V² |
| Eddy current loss | laminated core | thin insulated sheets |
| Hysteresis loss | soft iron core | narrow hysteresis loop |
Memory aids
"Parallel Peaks": emf peaks when the plane of the coil is parallel to B.
"NBA ω wins the game": peak emf = N B A ω, like an NBA team that wins with omega effort.
"Up in volts, down in amps": a step-up transformer raises voltage and lowers current; power stays the same.
"CHEF losses": C for copper, H for hysteresis, E for eddy, F for flux leakage.
"No DC at the transformer party": steady DC makes no changing flux, so no secondary emf.
Concept connections
Hysteresis and soft iron come from Physics Book 13: Magnetic Effects of Current and Magnetism.
Mutual induction (Chapter 3) and rms values (Chapter 4) of this book explain the transformer and generator ratings.
Energy conversion and efficiency link to Physics Book 4: Work, Energy and Power.
Practice MCQs: Chapter 8, Level 4 (new NEET pattern)
31. Match the part of an AC generator (List I) with its job (List II).
List I:
A. Armature coil
B. Slip rings
C. Brushes
D. Field magnet
List II:
(i) Keep each end of the coil joined to one brush as it rotates
(ii) Provides the magnetic field
(iii) Rotates and has the emf induced in it
(iv) Carbon contacts that lead current to the outer circuit
(a) A-i, B-iii, C-iv, D-ii (b) A-iii, B-iv, C-i, D-ii (c) A-ii, B-i, C-iv, D-iii (d) A-iii, B-i, C-iv, D-ii
32. Match the transformer loss (List I) with its remedy (List II).
List I:
A. Copper loss
B. Eddy current loss
C. Hysteresis loss
D. Flux leakage
List II:
(i) Soft iron core with a narrow hysteresis loop
(ii) Thick copper wire
(iii) Windings placed one over the other
(iv) Laminated core
(a) A-iv, B-ii, C-i, D-iii (b) A-ii, B-iv, C-i, D-iii (c) A-ii, B-i, C-iv, D-iii (d) A-iii, B-iv, C-i, D-ii
33. An ideal transformer has 200 primary turns on 220 V. Match the secondary turns (List I) with the secondary voltage (List II).
List I:
A. 1000
B. 50
C. 200
D. 20
List II:
(i) 22 V
(ii) 55 V
(iii) 220 V
(iv) 1100 V
(a) A-iv, B-iii, C-ii, D-i (b) A-ii, B-iv, C-iii, D-i (c) A-iv, B-ii, C-iii, D-i (d) A-iv, B-ii, C-i, D-iii
34. A generator coil has peak emf e0. θ is the angle between B and the normal to the coil. Match the position (List I) with the result (List II).
List I:
A. Plane of coil perpendicular to B
B. Plane of coil parallel to B
C. θ = 60°
D. θ = 30°
List II:
(i) emf = 0.5 e0
(ii) Flux maximum, emf zero
(iii) emf = 0.866 e0
(iv) Flux zero, emf maximum
(a) A-ii, B-iv, C-iii, D-i (b) A-iv, B-ii, C-iii, D-i (c) A-ii, B-iv, C-i, D-iii (d) A-ii, B-iii, C-iv, D-i
35. How many of the following statements are correct?
A. A transformer works on steady DC.
B. The output frequency of a transformer equals the input frequency.
C. A step-up transformer raises voltage and lowers current.
D. In an ideal transformer, Vp Ip = Vs Is.
E. A step-up transformer increases power.
(a) 2 (b) 4 (c) 5 (d) 3
36. For an AC generator with e = NBAω sin ωt, choose the correct set.
A. The peak emf doubles if ω doubles.
B. The frequency of the emf equals the rotation frequency.
C. For the same area, a circular coil gives a larger peak emf than a square coil.
D. The peak emf is proportional to N.
(a) A, B and D only (b) A and C only (c) B, C and D only (d) A, B, C and D
37. How many statements about long-distance transmission are correct?
A. Power lost in the line is proportional to I².
B. For fixed power, raising the voltage 10 times cuts the loss 100 times.
C. Step-down transformers near homes bring the voltage to 220 V.
D. Sending power at high current reduces loss.
(a) 1 (b) 2 (c) 3 (d) 4
38. Choose the correct set of statements about a transformer core.
A. It is made of soft iron.
B. Its laminations are insulated from each other.
C. It is laminated to reduce hysteresis loss.
D. It carries the flux of the primary to the secondary.
(a) A and C only (b) A, B and D only (c) B and C only (d) A, B, C and D
39. The emf–time graph of a generator is a sine curve with peak 100 V and period 20 ms. The coil has 50 turns of area 0.02 m². The field B is about: (a) 0.159 T (b) 0.637 T (c) 0.318 T (d) 3.18 T
40. A transformer is tested:
| Voltage (V) | Current (A) | |
|---|---|---|
| Primary | 220 | 2 |
| Secondary | 22 | 18 |
Its efficiency and type are: (a) 90%, step-down (b) 100%, step-down (c) 90%, step-up (d) 81%, step-down
41. A graph of the flux through a generator coil against time is a cosine curve (maximum at t = 0). Which is true for the emf graph? (a) The emf is maximum whenever the flux is maximum (b) The emf is maximum whenever the flux is zero (c) The emf and flux are in phase (d) The emf is zero throughout
Case for Q42–43: A small power station sends 200 kW to a town through lines of total resistance 5 Ω. Engineers compare sending it at 10 kV and at 2 kV.
42. The power lost in the lines at 10 kV is: (a) 2 kW (b) 20 kW (c) 0.2 kW (d) 50 kW
43. If the power is sent at 2 kV instead, the fraction of power lost is: (a) 1% (b) 5% (c) 25% (d) 50%
44. A rectangular coil of 200 turns, 0.2 m × 0.1 m, rotates at 3000 rpm in a 0.05 T field. The rms emf is about: (a) 62.8 V (b) 44.4 V (c) 31.4 V (d) 88.8 V
45. A step-down transformer of efficiency 80% works from 2200 V mains and delivers 4.4 kW at 220 V. The primary current is: (a) 2 A (b) 1.6 A (c) 25 A (d) 2.5 A
Level 4 answer key
| Q | Ans | Reason |
|---|---|---|
| 31 | d | Coil has the emf, slip rings keep contact, brushes carry current out, magnet gives the field |
| 32 | b | Thick wire, lamination, soft iron, overlapping windings |
| 33 | c | Vs = 220 × Ns/200: 1100, 55, 220, 22 V |
| 34 | a | e = e0 sin θ: 0 at θ = 0, e0 at 90°, 0.866 e0 at 60°, 0.5 e0 at 30° |
| 35 | d | B, C, D true; no DC operation; power cannot rise |
| 36 | a | e0 = NBAω depends on area only, not shape |
| 37 | c | A, B, C true; high current raises I²R loss |
| 38 | b | Lamination reduces eddy current loss, not hysteresis loss |
| 39 | c | ω = 2π/0.02 = 100π; B = 100/(50 × 0.02 × 100π) = 0.318 T |
| 40 | a | Output 396 W, input 440 W, η = 90%; voltage falls, so step-down |
| 41 | b | e = −dΦ/dt, so emf is largest where the flux crosses zero |
| 42 | a | I = 200 kW/10 kV = 20 A; loss = 400 × 5 = 2000 W |
| 43 | c | I = 100 A; loss = 10⁴ × 5 = 50 kW, which is 25% of 200 kW |
| 44 | b | ω = 100π; e0 = 200 × 0.05 × 0.02 × 100π = 62.8 V; rms = 44.4 V |
| 45 | d | Input = 4400/0.8 = 5500 W; Ip = 5500/2200 = 2.5 A |