Chapter 1: Magnetic Flux and Faraday's Law
What you will learn
What magnetic flux means and how to calculate it for a flat coil at any angle.
The simple experiments that show a changing flux drives a current.
Faraday's law in its full form, e = −N dΦ/dt, and how to use it.
The three ways to change flux: change B, change the area, or change the angle.
Why the total charge pushed round a coil depends only on the change in flux, not on how fast it happens.
1.1 Magnetic flux
Think of magnetic field lines as rain falling on an umbrella. The amount of rain the umbrella catches depends on how hard it rains, how big the umbrella is, and how you tilt it. Magnetic flux is the same idea for field lines passing through a surface.
For a flat surface of area A in a uniform field B, we draw the area vector A. Its size is the area, and its direction is along the normal (perpendicular) to the surface. Flux is the dot product:
Here θ is the angle between B and the normal to the surface, not the angle between B and the surface itself.

The loop is seen edge-on: tilting it away from the field lets fewer lines through, and the count follows cos θ of the angle between B and the normal.
θ = 0° (field along the normal, plane of loop perpendicular to B): Φ = BA, the maximum.
θ = 90° (field lying in the plane of the loop): Φ = 0. No line passes through.
θ = 180°: Φ = −BA. The sign only tells you the lines go through the other way.
Flux is a scalar. Its SI unit is the weber (Wb). From the formula, 1 Wb = 1 T m². Its dimensions are [ML²T⁻²A⁻¹]. The older unit maxwell is 10⁻⁸ Wb.
If B is not uniform, or the surface is curved, we split the surface into small pieces and add:
For a coil of N identical turns, each turn has the same flux Φ. The total, NΦ, is called the flux linkage.
1.2 Experiments that started it all
In 1831, Michael Faraday in England and Joseph Henry in the USA found that a magnet could produce a current. Their observations can be repeated in any school lab with a coil, a galvanometer and a bar magnet.
| Action | Galvanometer | What changed |
|---|---|---|
| Push N-pole of magnet towards the coil | Deflects one way | Flux through coil increases |
| Hold magnet still inside the coil | No deflection | Nothing changes |
| Pull magnet away | Deflects the other way | Flux decreases |
| Move magnet faster | Bigger deflection | Flux changes faster |
| Keep magnet still, move coil | Deflects | Relative motion changes flux |
| Switch on or off the current in a nearby second coil | Brief deflection | Flux from second coil changes |
| Steady current in the second coil | No deflection | Flux constant |
The common thread is clear. A current appears only while the flux through the coil is changing. A large flux that stays constant does nothing. This current is called the induced current, and the emf that drives it is the induced emf. The whole effect is electromagnetic induction.
1.3 Faraday's law of induction
Faraday's law says: the magnitude of the induced emf in a circuit equals the rate of change of magnetic flux through it. For a coil of N turns:
The minus sign is Lenz's law, which gives the direction (Chapter 2). For magnitudes, drop the sign.
Over a finite time Δt, the average emf is:
Check the units: Wb/s = T m²/s. Since T = N/(A m), this becomes N m/(A s) = J/C = V. So 1 Wb = 1 V s.
The instantaneous emf is the slope of the Φ–t graph. A flat part of the graph means zero emf, however large Φ is. A steep part means a large emf.
1.4 Induced current and induced charge
If the coil forms a closed circuit of total resistance R, the induced current is:
Now find the charge that flows. Since i = dq/dt:
The time has cancelled out. Push a magnet in slowly or quickly: the same total charge flows. Moving fast gives a bigger current for a shorter time. This result is a NEET favourite.
1.5 Three ways to change flux
Since Φ = BA cos θ, the flux changes if any of B, A or θ changes.
Changing B (coil fixed): e = NA cos θ (dB/dt). Example: a coil placed inside a solenoid whose current is being switched on.
Changing A (B fixed): e = NB cos θ (dA/dt). Example: a rod sliding on rails, or a loop being stretched. Chapter 2 treats this as motional emf.
Changing θ (B and A fixed): if a coil rotates with angular speed ω, then θ = ωt and Φ = BA cos ωt. So e = NBAω sin ωt. This is the AC generator of Chapter 8.
| Quantity changed | Formula for emf (magnitude) | Everyday device |
|---|---|---|
| B | NA cos θ (dB/dt) | Transformer, induction cooktop |
| A | NB cos θ (dA/dt) | Sliding rod, expanding loop |
| θ | NBAω sin ωt | Generator in a dam or a bicycle dynamo |
A changing magnetic field also creates an electric field in space, even with no wire present. This induced electric field forms closed loops, so it is non-conservative. That is what pushes the charges round a stationary coil. NEET needs only this idea, not its maths.
Worked example 1.1: A square loop of side 5 cm lies in a uniform field of 0.4 T. The normal to the loop makes 60° with the field. Find the flux.
Solution: A = (0.05)² = 2.5 × 10⁻³ m². Φ = BA cos 60° = 0.4 × 2.5 × 10⁻³ × 0.5 = 5 × 10⁻⁴ Wb.
Worked example 1.2: A circular loop of radius 10 cm is placed so that its plane makes 30° with a uniform field of 0.2 T. Find the flux.
Solution: The plane is at 30°, so the normal is at 90° − 30° = 60° to B. A = π(0.1)² = 0.0314 m². Φ = 0.2 × 0.0314 × cos 60° = 3.14 × 10⁻³ Wb. Using cos 30° here is the most common slip.
Worked example 1.3: A 200-turn coil of area 40 cm² has its normal along a uniform field. The field falls from 0.5 T to 0.1 T in 0.02 s. Find the average induced emf.
Solution: ΔB = 0.4 T. e = NA ΔB/Δt = 200 × 40 × 10⁻⁴ × 0.4 / 0.02 = 200 × 0.004 × 20 = 16 V.
Worked example 1.4: The flux through a single loop varies as Φ = (3t² + 2t + 1) mWb, with t in seconds. The loop has resistance 7 Ω. Find the emf and current at t = 2 s.
Solution: e = dΦ/dt = (6t + 2) mV. At t = 2 s, e = 14 mV. Current i = 14 mV / 7 Ω = 2 mA.
Worked example 1.5: A coil of 100 turns and radius 7 cm sits in a uniform field perpendicular to its plane. The field increases at 0.05 T/s. Find the emf. (Take π = 22/7.)
Solution: A = (22/7) × (0.07)² = 0.0154 m². e = NA dB/dt = 100 × 0.0154 × 0.05 = 0.077 V = 77 mV.
Worked example 1.6: A 50-turn coil of area 0.02 m² and resistance 10 Ω lies with its plane perpendicular to a 0.3 T field. It is flipped through 180°. How much charge flows?
Solution: Before the flip Φ = +BA per turn. After the flip Φ = −BA. So ΔΦ = 2BA = 2 × 0.3 × 0.02 = 0.012 Wb. q = NΔΦ/R = 50 × 0.012 / 10 = 0.06 C. The time taken to flip is not needed.
Worked example 1.7: A circular loop in a 0.5 T field (perpendicular to its plane) is shrinking. At the instant its radius is 4 cm, the radius decreases at 2 mm/s. Find the emf at that instant.
Solution: A = πr², so dA/dt = 2πr (dr/dt). e = B × 2πr × dr/dt = 0.5 × 2π × 0.04 × 0.002 = 2.51 × 10⁻⁴ V ≈ 0.25 mV.
Worked example 1.8 (NEET-hard): A long solenoid has 2000 turns per metre. A small coil of 100 turns and area 3 cm² is placed coaxially inside it. The solenoid current rises steadily from 0 to 4 A in 0.1 s. Find the emf in the small coil.
Solution: Inside a long solenoid B = μ0nI. Change in B = 4π × 10⁻⁷ × 2000 × 4 = 1.005 × 10⁻² T. e = NA ΔB/Δt = 100 × 3 × 10⁻⁴ × 1.005 × 10⁻² / 0.1 = 3.0 × 10⁻³ V = 3.0 mV.
Quick revision
Φ = BA cos θ, with θ measured from the normal. Unit: weber = T m² = V s.
Flux linkage of an N-turn coil = NΦ.
Faraday: e = −N dΦ/dt. Average emf = NΔΦ/Δt.
Induced current i = e/R. Induced charge q = NΔΦ/R, independent of time.
Flux changes through B, A or θ. Rotating coil: e = NBAω sin ωt.
Constant flux, however large, induces nothing.
Flipping a coil by 180° changes flux by 2BA, not BA.
NEET traps
Using the angle between B and the plane of the loop in BA cos θ. The angle must be with the normal.
Forgetting N in the emf, or counting it twice in q = NΔΦ/R.
Taking ΔΦ = BA for a 180° flip. It is 2BA.
Thinking a fast-moving magnet sends more total charge. It sends the same charge, faster.
Reading emf from the height of a Φ–t graph instead of its slope.
Mixing cm² and m². 1 cm² = 10⁻⁴ m².
Practice MCQs: Chapter 1
Level 1: Concept check
1. The SI unit of magnetic flux is (a) tesla (b) weber (c) henry (d) gauss
2. The flux through a flat loop in a uniform field is zero when the plane of the loop is (a) perpendicular to the field (b) at 45° to the field (c) at 60° to the field (d) parallel to the field
3. One weber is equal to (a) 1 T m² (b) 1 T/m² (c) 1 V/s (d) 1 A m²
4. According to Faraday's law, the induced emf in a coil is proportional to (a) the magnetic flux linked (b) the magnetic field (c) the rate of change of flux linkage (d) the area of the coil only
5. A square loop of side 10 cm is held with its normal along a uniform field of 0.5 T. The flux through it is (a) 0.5 Wb (b) 5 × 10⁻³ Wb (c) 5 × 10⁻² Wb (d) 5 × 10⁻⁴ Wb
6. The flux through a single-turn loop changes by 4 mWb in 0.2 s. The average induced emf is (a) 0.8 mV (b) 2 mV (c) 50 mV (d) 20 mV
7. A strong bar magnet is held at rest inside a coil connected to a galvanometer. The induced emf is (a) zero (b) maximum (c) constant and non-zero (d) alternating
8. The dimensional formula of magnetic flux is (a) [MLT⁻²A⁻¹] (b) [MT⁻²A⁻¹] (c) [ML²T⁻²A⁻¹] (d) [ML²T⁻¹A⁻¹]
9. The total charge that flows through a closed coil when the flux through it changes depends on (a) the time taken for the change (b) the change in flux linkage and the resistance (c) the speed of the magnet only (d) the rate of change of flux only
10. Magnetic flux is (a) a vector along B (b) a vector along the normal to the area (c) dimensionless (d) a scalar
Level 2: NEET standard
11. A 100-turn circular coil of radius 5 cm has its plane perpendicular to a uniform field. The field rises from 0.2 T to 0.6 T in 0.1 s. The average emf is about (a) 3.14 V (b) 0.314 V (c) 31.4 V (d) 1.57 V
12. The flux through a loop is Φ = (5t² − 4t + 2) Wb. The magnitude of the emf at t = 1 s is (a) 3 V (b) 10 V (c) 6 V (d) 14 V
13. A loop of area 0.05 m² has its plane perpendicular to a 0.4 T field. It is turned through 90° in 0.5 s so that its plane becomes parallel to the field. The average emf is (a) 0.4 V (b) 0.04 V (c) 0.01 V (d) zero
14. A 20-turn coil of area 0.01 m² and resistance 4 Ω lies with its plane perpendicular to a 0.8 T field. It is pulled out of the field completely. The charge that flows is (a) 0.4 C (b) 0.004 C (c) 0.16 C (d) 0.04 C
15. A 10-turn coil of area 0.02 m² and resistance 2 Ω has its plane perpendicular to a 0.5 T field. It is flipped through 180°. The charge that flows is (a) 0.1 C (b) 0.05 C (c) 0.2 C (d) zero
16. The flux through a loop rises uniformly from 0 to 6 mWb in 2 ms, stays constant for 2 ms, then falls uniformly to zero in 1 ms. The ratio of emf magnitudes in the first and last intervals is (a) 2 : 1 (b) 1 : 3 (c) 1 : 2 (d) 3 : 1
17. A 50-turn coil of area 0.1 m² and resistance 5 Ω is in a field B = (0.2 + 0.05t) T perpendicular to its plane. The induced current is (a) 25 mA (b) 50 mA (c) 5 mA (d) 250 mA
18. A long solenoid has 1000 turns per metre. A 50-turn coil of area 2 cm² is placed coaxially inside it. The solenoid current changes by 2 A in 0.01 s. The emf in the coil is about (a) 25 mV (b) 0.25 mV (c) 1.25 mV (d) 2.5 mV
19. For a coil in a field changing at a fixed rate, the area is doubled and the number of turns is halved. The induced emf (a) stays the same (b) doubles (c) halves (d) becomes four times
20. A square loop is in a 0.5 T field perpendicular to its plane. Its side grows at 2 cm/s. At the instant the side is 10 cm, the emf is (a) 1 mV (b) 4 mV (c) 2 mV (d) 0.2 mV
21. The flux through each turn of a 200-turn coil is Φ = 2 × 10⁻³ sin(100t) Wb. The peak emf is (a) 0.4 V (b) 40 V (c) 20 V (d) 4 V
22. A plane loop lies in a uniform, steady field perpendicular to its plane. Which of these will NOT induce an emf? (a) Changing the strength of the field (b) Rotating the loop about a diameter (c) Changing the area of the loop (d) Moving the loop sideways while it stays fully inside the field
Level 3: Challenge
23. The flux through a loop is Φ = 4t(3 − t) mWb, with t in seconds. The emf at t = 0.5 s is (a) 8 mV (b) 12 mV (c) 4 mV (d) zero
24. The flux linkage of a coil of resistance 10 Ω varies as NΦ = (t² − 4t) Wb. The magnitude of charge that flows between t = 0 and t = 2 s is (a) zero (b) 0.8 C (c) 0.4 C (d) 0.2 C
25. A flexible circular loop of radius 7 cm lies in a 0.2 T field perpendicular to its plane. In 0.1 s it is pulled into a square of the same perimeter, still in the same plane. The average emf is (take π = 22/7) (a) 3.3 mV (b) 6.6 mV (c) 66 mV (d) 0.66 mV
26. A 100-turn coil of area 0.01 m² and resistance 4 Ω sits in a field perpendicular to its plane changing at 0.2 T/s. The power dissipated in the coil is (a) 40 mW (b) 50 mW (c) 1 mW (d) 10 mW
27. A fixed length of wire is wound first into a one-turn circular coil and then into a two-turn circular coil. Both are placed in the same changing field, perpendicular to the plane. The ratio of emf (two-turn : one-turn) is (a) 2 : 1 (b) 1 : 2 (c) 1 : 1 (d) 1 : 4
28. Two circular loops of radii r and 2r are made from the same uniform wire. Both lie in a region where a uniform field perpendicular to them changes at a steady rate. The ratio of induced currents (smaller : larger) is (a) 1 : 2 (b) 1 : 4 (c) 2 : 1 (d) 1 : 1
29. Assertion (A): When a strong magnet is held at rest inside a coil, no current flows in the coil even though the flux linked is large. Reason (R): The induced emf depends on the rate of change of flux, not on the flux itself. (a) Both true, R explains A (b) Both true, R does not explain A (c) A true, R false (d) A false, R true
30. Statement I: One weber is equal to one volt-second. Statement II: The total charge that flows through a coil is larger when the magnet is moved in faster. (a) Both true (b) Both false (c) I true, II false (d) I false, II true
Answer key with reasons
| Q | Ans | Reason |
|---|---|---|
| 1 | b | Flux is measured in weber |
| 2 | d | Field in the plane means θ = 90° from normal |
| 3 | a | Φ = BA gives T m² |
| 4 | c | e = −N dΦ/dt |
| 5 | b | 0.5 × 0.01 = 5 × 10⁻³ Wb |
| 6 | d | 4 mWb / 0.2 s = 20 mV |
| 7 | a | Flux is constant, so no emf |
| 8 | c | Wb = V s = [ML²T⁻³A⁻¹][T] |
| 9 | b | q = NΔΦ/R, time cancels |
| 10 | d | Dot product of two vectors is a scalar |
| 11 | a | 100 × π(0.05)² × 0.4 / 0.1 = 3.14 V |
| 12 | c | dΦ/dt = 10t − 4 = 6 V at t = 1 s |
| 13 | b | ΔΦ = BA = 0.02 Wb, divided by 0.5 s |
| 14 | d | 20 × 0.8 × 0.01 / 4 = 0.04 C |
| 15 | a | ΔΦ = 2BA; 10 × 0.02 / 2 = 0.1 C |
| 16 | c | 3 V and 6 V |
| 17 | b | e = 50 × 0.1 × 0.05 = 0.25 V; i = 0.05 A |
| 18 | d | dB/dt = μ0n dI/dt = 0.251 T/s; e = 50 × 2 × 10⁻⁴ × 0.251 |
| 19 | a | NA is unchanged |
| 20 | c | e = B × 2a × da/dt = 0.5 × 0.2 × 0.02 = 2 mV |
| 21 | b | e0 = NΦ0ω = 200 × 0.002 × 100 |
| 22 | d | Uniform field: flux stays the same while sliding |
| 23 | a | dΦ/dt = 12 − 8t = 8 mV at 0.5 s |
| 24 | c | NΦ goes 0 to −4 Wb; q = 4/10 |
| 25 | b | Area falls from 154 to 121 cm²; 0.2 × 33 × 10⁻⁴ / 0.1 |
| 26 | d | e = 0.2 V; P = e²/R = 0.01 W |
| 27 | b | NA: two turns give L²/8π vs one turn L²/4π |
| 28 | a | e ∝ r², R ∝ r, so i ∝ r |
| 29 | a | Constant flux gives zero emf; R is the reason |
| 30 | c | q = NΔΦ/R does not depend on speed |
Chapter 1 revision sheet
One-page summary
Magnetic flux through a flat loop in a uniform field: Φ = BA cos θ, where θ is the angle between B and the normal to the loop.
Flux is a scalar. SI unit weber (Wb); 1 Wb = 1 T m² = 1 V s.
Φ is maximum (BA) when the plane of the loop is perpendicular to B, and zero when the plane is parallel to B.
In a non-uniform field, Φ = ∫ B · dA. For N turns, flux linkage = NΦ.
Faraday's experiments: a current is induced only while the flux through the coil is changing. Faster change gives a bigger deflection.
Faraday's law: e = −N dΦ/dt. The minus sign is Lenz's law (direction).
Average emf over a finite change: e = NΔΦ/Δt (magnitude).
An induced emf exists even in an open circuit; a current needs a closed path.
Induced current: i = e/R = (N/R) dΦ/dt.
Induced charge: q = NΔΦ/R. It does not depend on how fast the flux changes.
Three ways to change flux: change B (magnet moved), change A (rod sliding, loop stretched), change θ (coil rotating).
A coil flipped through 180° in a field has ΔΦ = 2BA, not BA.
If Φ is a function of time, emf is its slope: a linear Φ–t graph gives constant emf; a flat portion gives zero emf.
Must-remember table
| Quantity | Formula | SI unit |
|---|---|---|
| Magnetic flux | Φ = BA cos θ | Wb = T m² |
| Flux linkage | NΦ | Wb (weber-turn) |
| Instantaneous emf | e = −N dΦ/dt | V = Wb/s |
| Average emf | NΔΦ/Δt | V |
| Induced current | e/R | A |
| Induced charge | NΔΦ/R | C |
| Dimensions of flux | [M L² T⁻² A⁻¹] | — |
Memory aids
"BAT" for flux: B (field), A (area), T for theta (the angle with the normal). All three can change; any change gives emf.
"Charge is a lazy cow": charge does not care how fast you move. q = NΔΦ/R has no time in it.
"Flip doubles": turning a coil upside down in a field changes the flux from +BA to −BA, so ΔΦ = 2BA.
"Slope is emf": on a Φ–t graph, the steeper the line, the bigger the emf; flat line, zero emf.
Concept connections
Magnetic field of a solenoid, a straight wire and a loop comes from Physics Book 13: Magnetic Effects of Current and Magnetism.
Induced current, resistance and charge use Ohm's law from Physics Book 12: Current Electricity.
Changing magnetic flux producing an electric field is the seed of Physics Book 15: Electromagnetic Waves.
Practice MCQs: Chapter 1, Level 4 (new NEET pattern)
31. Match List I with List II.
List I:
A. Magnetic flux
B. Rate of change of flux linkage
C. Flux linkage per unit current (NΦ/I)
D. NΔΦ/R for a coil
List II:
(i) henry
(ii) weber
(iii) volt
(iv) coulomb
(a) A-iii, B-ii, C-i, D-iv (b) A-ii, B-iii, C-i, D-iv (c) A-ii, B-iii, C-iv, D-i (d) A-i, B-iii, C-ii, D-iv
32. For a single loop, the flux Φ (in Wb, t in s) is given in List I. Match each with the emf in List II.
List I:
A. Φ = 5t², emf at t = 2 s
B. Φ = 4 × 10⁻³ sin 50t, peak emf
C. Φ = 6t + 3, emf at any time
D. Φ = 8, emf at any time
List II:
(i) 0
(ii) 6 V
(iii) 20 V
(iv) 0.2 V
(a) A-iv, B-iii, C-ii, D-i (b) A-iii, B-ii, C-iv, D-i (c) A-iii, B-iv, C-ii, D-i (d) A-ii, B-iv, C-iii, D-i
33. Match the way of changing flux (List I) with an example (List II).
List I:
A. Changing B
B. Changing A
C. Changing θ
D. No change in flux
List II:
(i) A rod sliding on rails in a field
(ii) A loop moving sideways inside a uniform field
(iii) A magnet pushed toward a fixed coil
(iv) A coil spinning between magnet poles
(a) A-i, B-iii, C-iv, D-ii (b) A-iii, B-iv, C-i, D-ii (c) A-iii, B-i, C-ii, D-iv (d) A-iii, B-i, C-iv, D-ii
34. A coil of resistance R has a charge q driven through it when it is pulled out of a field. Match the change (List I) with the new charge (List II).
List I:
A. Number of turns doubled, R unchanged
B. Resistance doubled
C. Coil pulled out twice as fast
D. Turns doubled and coil radius doubled, R unchanged
List II:
(i) q
(ii) 2q
(iii) 8q
(iv) q/2
(a) A-ii, B-iv, C-i, D-iii (b) A-ii, B-i, C-iv, D-iii (c) A-iii, B-iv, C-i, D-ii (d) A-iv, B-ii, C-i, D-iii
35. How many of the following statements are correct?
A. Magnetic flux is a vector quantity.
B. 1 Wb = 1 V s.
C. Induced emf depends on the rate of change of flux, not on the flux itself.
D. The induced charge depends on the time taken for the flux change.
E. A coil moving sideways inside a uniform field has no induced emf.
(a) 2 (b) 3 (c) 4 (d) 5
36. Choose the correct set of statements about Faraday's coil-and-magnet experiments.
A. The galvanometer deflects only while the magnet moves relative to the coil.
B. A magnet held still inside the coil gives a steady deflection.
C. Switching a nearby circuit on or off gives a brief deflection.
D. Faster motion of the magnet gives a bigger deflection.
(a) A, B and C only (b) B and D only (c) C and D only (d) A, C and D only
37. A flat loop of area A is in a uniform field B; θ is the angle between B and the normal to the loop. Choose the correct set.
A. Flux is maximum when the plane of the loop is perpendicular to B.
B. Flux is zero when the plane of the loop is parallel to B.
C. Φ = BA sin θ.
D. For the same area, a circular loop links more flux than a square loop.
(a) A and B only (b) A, B and C only (c) C and D only (d) A and D only
38. How many of the following statements are correct?
A. The minus sign in Faraday's law gives the direction of the induced emf.
B. An emf is induced in an open coil when its flux changes.
C. A current flows in an open coil when its flux changes.
D. For N identical turns linked by the same flux, the emf is N times that of one turn.
(a) 1 (b) 2 (c) 3 (d) 4
39. The flux through each turn of a 10-turn coil changes as follows: it rises linearly from 0 to 6 mWb between t = 0 and t = 2 s, stays at 6 mWb from 2 s to 4 s, and falls linearly to 0 between 4 s and 5 s. The emf magnitudes in the three intervals are: (a) 30 mV, 0, 60 mV (b) 30 mV, 30 mV, 60 mV (c) 3 mV, 0, 6 mV (d) 60 mV, 0, 30 mV
40. A 50-turn coil of area 0.02 m² has a field normal to its plane that changes as in the table.
| t (s) | 0 | 0.1 | 0.2 | 0.3 |
|---|---|---|---|---|
| B (T) | 0.10 | 0.30 | 0.50 | 0.50 |
The average emf from 0 to 0.2 s and from 0.2 s to 0.3 s is: (a) 1 V, 0 (b) 2 V, 0 (c) 2 V, 1 V (d) 4 V, 0
41. The flux through a loop varies as Φ = 2t² (a parabola). The graph of emf magnitude against time is: (a) a horizontal line (b) a parabola (c) a hyperbola (d) a straight line through the origin
Case for Q42–43: A 200-turn coil of area 50 cm² and resistance 4 Ω is joined to a galvanometer of resistance 6 Ω. The coil sits with its plane perpendicular to a uniform field of 0.3 T. A student pulls it completely out of the field in 0.1 s.
42. The average emf induced in the coil is: (a) 0.3 V (b) 1.5 V (c) 3 V (d) 30 V
43. The charge through the galvanometer, if the student instead takes 0.2 s to pull the coil out, is: (a) 30 mC (b) 15 mC (c) 3 mC (d) 300 mC
44. A 100-turn coil of area 0.01 m² lies with its plane perpendicular to a 0.5 T field. It is turned through 180° in 0.05 s. The average emf is: (a) 10 V (b) 20 V (c) 0 (d) 40 V
45. A single loop has a field B = 0.4t (tesla) normal to it, while its area grows as A = 0.02t (m²). The emf at t = 5 s is: (a) 40 mV (b) 16 mV (c) 80 mV (d) 8 mV
Level 4 answer key
| Q | Ans | Reason |
|---|---|---|
| 31 | b | Flux in Wb, d(NΦ)/dt in V, NΦ/I in H, NΔΦ/R in C |
| 32 | c | 10t = 20 V; 4 × 10⁻³ × 50 = 0.2 V; slope 6 V; constant flux gives 0 |
| 33 | d | Magnet moves (B), rod slides (A), coil spins (θ), sideways in uniform field (none) |
| 34 | a | q = NΔΦ/R: 2N gives 2q; 2R gives q/2; speed no effect; 2N × 4A gives 8q |
| 35 | b | B, C, E are true; flux is scalar; charge is independent of time |
| 36 | d | Steady magnet gives no deflection, so B is false |
| 37 | a | Φ = BA cos θ, so C is false; in a uniform field only area matters, so D is false |
| 38 | c | A, B, D true; no current without a closed path |
| 39 | a | 10 × 3 mWb/s = 30 mV; 0; 10 × 6 mWb/s = 60 mV |
| 40 | b | 50 × 0.02 × 0.4/0.2 = 2 V; B constant afterwards gives 0 |
| 41 | d | e = dΦ/dt = 4t, a straight line through the origin |
| 42 | c | 200 × 0.3 × 5 × 10⁻³/0.1 = 3 V |
| 43 | a | q = NΔΦ/R = 200 × 1.5 × 10⁻³/10 = 0.03 C, same for any time |
| 44 | b | ΔΦ = 2BA = 0.01 Wb per turn; 100 × 0.01/0.05 = 20 V |
| 45 | c | Φ = 0.008t², e = 0.016t = 0.08 V at 5 s |