Chapter 7: Power in AC Circuits
What you will learn
How to derive the average power P = VrmsIrms cos φ.
What power factor means, and its value for R, L, C and LCR circuits.
Apparent power and true power, and why their ratio matters to power companies.
Wattless current: the part of the current that does no work on average.
Why a choke coil, not a resistor, is used to limit AC current.
7.1 Average power in an AC circuit
Let v = V0 sin ωt and i = I0 sin(ωt − φ). The instantaneous power is p = vi. Use 2 sin A sin B = cos(A − B) − cos(A + B):
The second term swings at twice the supply frequency. Over a full cycle it averages to zero. Only the first term remains:
In a series LCR circuit, cos φ = R/Z and Irms = Vrms/Z. So P = Vrms × (Vrms/Z) × (R/Z) = Irms²R. Only the resistor takes power on average. The inductor and capacitor take energy in one quarter cycle and give it back in the next.
7.2 Power factor
The factor cos φ is the power factor. It lies between 0 and 1.
| Circuit | Phase angle φ | Power factor | Average power |
|---|---|---|---|
| Pure R | 0 | 1 | VrmsIrms |
| Pure L | 90° (lag) | 0 | Zero |
| Pure C | 90° (lead) | 0 | Zero |
| Series RL or RC | Between 0 and 90° | R/Z | Irms²R |
| Series LCR at resonance | 0 | 1 | Vrms²/R (maximum) |
Apparent power and true power. The product VrmsIrms is the apparent power, measured in volt-ampere (VA). The actual average power, VrmsIrms cos φ, is the true power, in watt (W). Power factor = true power ÷ apparent power. Transformers and generators are rated in kVA because their heating depends on current, whatever the power factor.
Why a low power factor is bad. For a fixed power P at voltage V, the current needed is I = P/(V cos φ). A low cos φ needs a larger current. The supply lines and transformers then waste more energy as I²R heat. Factories with many motors (which are inductive) connect banks of capacitors to bring cos φ close to 1. Electricity boards often charge a penalty for a low power factor.
7.3 Wattless current
Draw the current phasor at angle φ behind the voltage phasor. Split it into two parts:
Irms cos φ, along the voltage. This part carries power. It is the active (wattful) component.
Irms sin φ, at 90° to the voltage. Power from this part averages to zero. It is the wattless current.
In a pure L or pure C, the whole current is wattless. In a pure R, none of it is. The wattless current still flows in the wires and still heats them, though it delivers no power to the load.
7.4 The choke coil
Old tube lights, fan regulators and some lamps need less current than the mains would push through them. One way is to add a resistor in series. But a resistor wastes power as heat. A better way is a coil of large inductance and very small resistance, called a choke.
The choke adds reactance, which cuts the current. Being nearly pure inductance, its power factor is nearly zero, so it wastes almost no energy. The current it carries is almost all wattless. Choke coils are used only with AC; on DC an inductor gives no opposition once the current is steady.
Worked example 7.1: A device draws 5 A (rms) from 220 V (rms) mains, with the current lagging by 60°. Find the average power.
Solution: P = 220 × 5 × cos 60° = 1100 × 0.5 = 550 W.
Worked example 7.2: For the circuit in Worked example 6.1 (R = 30 Ω, Z = 50 Ω, 200 V, 4 A), find the power factor and power.
Solution: cos φ = 30/50 = 0.6. P = 200 × 4 × 0.6 = 480 W. Check: Irms²R = 16 × 30 = 480 W.
Worked example 7.3: In a circuit, v = 100 sin ωt volt and i = 2 sin(ωt − π/3) ampere. Find the average power.
Solution: P = (V0I0/2) cos φ = (100 × 2/2) × cos 60° = 100 × 0.5 = 50 W.
Worked example 7.4: A load draws 10 A (rms) at a power factor of 0.8. Find the active and wattless parts of the current.
Solution: cos φ = 0.8, so sin φ = 0.6. Active part = 10 × 0.8 = 8 A. Wattless part = 10 × 0.6 = 6 A.
Worked example 7.5: A coil draws 4 A from a 12 V DC supply. On a 12 V (rms), 50 Hz supply it draws 2.4 A. Find its resistance, reactance, power factor and power on AC.
Solution: On DC only resistance acts: R = 12/4 = 3 Ω. On AC, Z = 12/2.4 = 5 Ω, so XL = √(25 − 9) = 4 Ω. Power factor = R/Z = 0.6. P = 12 × 2.4 × 0.6 = 17.3 W. Check: 2.4² × 3 = 17.3 W.
Worked example 7.6: A series LCR circuit with R = 10 Ω is at resonance on a 100 V (rms) supply. Find the power.
Solution: At resonance Z = R and cos φ = 1. P = V²/R = 10000/10 = 1000 W.
Worked example 7.7: A lamp rated 100 V, 5 A is to be run from 200 V, 50 Hz mains using a pure choke. Find the inductance. Compare with using a resistor.
Solution: Lamp resistance R = 100/5 = 20 Ω. For 5 A from 200 V, Z = 40 Ω. XL = √(40² − 20²) = √1200 = 34.6 Ω. L = 34.6/(2π × 50) = 0.11 H. A series resistor would need to be 20 Ω and would waste 5² × 20 = 500 W. The choke wastes almost nothing.
Worked example 7.8 (NEET-hard): An RL circuit has R = 30 Ω and XL = 40 Ω on a 100 V (rms) supply. A capacitor is added in series so that the power factor becomes 1. Find XC and the power before and after.
Solution: Before: Z = 50 Ω, I = 2 A, P = 4 × 30 = 120 W, cos φ = 0.6. For unit power factor, XC = XL = 40 Ω. After: Z = 30 Ω, I = 3.33 A, P = 100²/30 = 333 W. The power rises by a factor (50/30)² = 25/9.
Quick revision
P = VrmsIrms cos φ = Irms²R = (V0I0/2) cos φ.
Power factor cos φ = R/Z = true power/apparent power.
Pure R: cos φ = 1. Pure L or C: cos φ = 0. LCR at resonance: 1.
Apparent power in VA; true power in W.
Active current Irms cos φ; wattless current Irms sin φ.
Choke: large L, tiny R; limits AC current with almost no power loss.
Low power factor means more current and more line loss for the same power.
NEET traps
Writing P = VrmsIrms and forgetting cos φ.
Using peak values without the ½: P = V0I0 cos φ is wrong by a factor 2.
Calling Irms cos φ the wattless current. Wattless is Irms sin φ.
Finding φ from one phase only. Use the difference of the voltage and current phases.
Thinking a choke works on DC. It only limits changing current.
Assuming a high-current device always uses more power. Check its power factor.
Practice MCQs: Chapter 7
Level 1: Concept check
1. The average power in an AC circuit is (a) VrmsIrms (b) VrmsIrms cos φ (c) V0I0 cos φ (d) VrmsIrms sin φ
2. The power factor of a purely resistive circuit is (a) 0 (b) 0.5 (c) 0.707 (d) 1
3. The power factor of a purely inductive circuit is (a) 0 (b) 1 (c) 0.5 (d) infinite
4. The wattless component of an alternating current is (a) Irms cos φ (b) Irms (c) Irms sin φ (d) Irms tan φ
5. The power factor of a series LCR circuit at resonance is (a) 0 (b) 1 (c) R/XL (d) 0.5
6. The unit of apparent power is the (a) volt-ampere (b) watt (c) joule (d) ohm
7. A choke coil is preferred to a resistor for limiting AC current because the choke (a) has higher resistance (b) works on DC too (c) increases the power factor to 1 (d) wastes very little power
8. The power factor of a series LCR circuit equals (a) Z/R (b) X/Z (c) R/Z (d) X/R
9. Electricity boards discourage a low power factor because, for the same power, it needs (a) a lower current (b) a larger current, raising line losses (c) a higher frequency (d) a lower voltage
10. The average power drawn by a pure capacitor connected to an AC source is (a) zero (b) VrmsIrms (c) V0I0/2 (d) infinite
Level 2: NEET standard
11. A load draws 5 A (rms) from 220 V (rms) with the current lagging by 60°. The power is (a) 1100 W (b) 952 W (c) 550 W (d) 275 W
12. A series circuit has R = 30 Ω, XL = 80 Ω and XC = 40 Ω on 200 V (rms). The average power is (a) 480 W (b) 640 W (c) 800 W (d) 360 W
13. In a circuit, v = 100 sin ωt volt and i = 2 sin(ωt − π/3) ampere. The average power is (a) 100 W (b) 200 W (c) 86.6 W (d) 50 W
14. A load draws 10 A (rms) at a power factor of 0.8. The wattless current is (a) 8 A (b) 6 A (c) 10 A (d) 2 A
15. A coil draws 4 A from 12 V DC and 2.4 A from 12 V (rms) AC. Its power factor on AC is (a) 0.8 (b) 0.5 (c) 0.6 (d) 0.75
16. For the coil in Q15, the power on AC is about (a) 17.3 W (b) 28.8 W (c) 48 W (d) 11.5 W
17. An RL circuit has R = 40 Ω and XL = 30 Ω on 100 V (rms). The average power is (a) 200 W (b) 120 W (c) 250 W (d) 160 W
18. The power factor of a series RC circuit with R = XC is (a) 1 (b) 0.707 (c) 0.5 (d) zero
19. A machine takes 1 kW from 250 V (rms) mains at a power factor of 0.8. The current is (a) 4 A (b) 6.25 A (c) 5 A (d) 3.2 A
20. A lamp rated 100 V, 5 A is run on 200 V, 50 Hz mains with a pure choke in series. The choke's inductance is about (a) 0.11 H (b) 0.064 H (c) 0.22 H (d) 0.035 H
21. A series LCR circuit with R = 10 Ω is at resonance on 100 V (rms). The power is (a) 100 W (b) 500 W (c) 10 W (d) 1000 W
22. In a circuit, v = 200 sin(100πt) V and i = 5 cos(100πt) A. The average power is (a) 500 W (b) zero (c) 1000 W (d) 250 W
Level 3: Challenge
23. A series circuit has R = 60 Ω, XL = 120 Ω and XC = 40 Ω on 200 V (rms). The average power is (a) 400 W (b) 320 W (c) 240 W (d) 160 W
24. In a series LCR circuit, at either half-power frequency, the power factor is (a) 1 (b) 0.5 (c) zero (d) 1/√2
25. An RL circuit (R = 30 Ω, XL = 40 Ω) is on a fixed AC voltage. A capacitor is added in series to make the power factor 1. The ratio of new power to old power is (a) 5/3 (b) 25/9 (c) 9/25 (d) 1
26. A load on a 200 V (rms) line has an apparent power of 2000 VA and a true power of 1600 W. The wattless current is (a) 6 A (b) 8 A (c) 10 A (d) 4 A
27. In a circuit, v = 100 sin(ωt + π/6) volt and i = 4 sin(ωt − π/6) ampere. The average power is (a) 200 W (b) 173 W (c) 50 W (d) 100 W
28. A fan draws 0.5 A (rms) from 220 V (rms) mains at a power factor of 0.8. The energy it uses in one hour is (a) 0.11 kWh (b) 0.088 kWh (c) 0.055 kWh (d) 0.176 kWh
29. Assertion (A): A choke coil is preferred to a resistor for controlling the current in an AC circuit. Reason (R): The average power taken by an ideal inductor is zero. (a) Both true, R explains A (b) Both true, R does not explain A (c) A true, R false (d) A false, R true
30. Statement I: The wattless current is in phase with the applied voltage. Statement II: The power factor of a series LCR circuit at resonance is 1. (a) Both true (b) Both false (c) I true, II false (d) I false, II true
Answer key with reasons
| Q | Ans | Reason |
|---|---|---|
| 1 | b | The cos(2ωt − φ) term averages out |
| 2 | d | φ = 0 |
| 3 | a | φ = 90° |
| 4 | c | Component at 90° to voltage |
| 5 | b | Z = R at resonance |
| 6 | a | VrmsIrms is in VA |
| 7 | d | Ideal inductor takes no average power |
| 8 | c | From the impedance triangle |
| 9 | b | I = P/(V cos φ) rises as cos φ falls |
| 10 | a | φ = 90° |
| 11 | c | 220 × 5 × 0.5 |
| 12 | a | Z = 50, I = 4 A; 16 × 30 |
| 13 | d | (100 × 2/2) × 0.5 |
| 14 | b | 10 × sin φ = 10 × 0.6 |
| 15 | c | R = 3 Ω, Z = 5 Ω |
| 16 | a | 2.4² × 3 = 17.28 W |
| 17 | d | Z = 50, I = 2 A; 4 × 40 |
| 18 | b | Z = √2 R, so R/Z = 1/√2 |
| 19 | c | I = 1000/(250 × 0.8) |
| 20 | a | XL = √(40² − 20²) = 34.6 Ω; divide by 100π |
| 21 | d | V²/R = 10⁴/10 |
| 22 | b | Current leads by 90°, cos φ = 0 |
| 23 | c | Z = 100, I = 2 A; 4 × 60 |
| 24 | d | There Z = √2 R |
| 25 | b | P ∝ 1/Z²; (50/30)² |
| 26 | a | I = 10 A, cos φ = 0.8, sin φ = 0.6 |
| 27 | d | φ = π/3; (100 × 4/2) × 0.5 |
| 28 | b | P = 220 × 0.5 × 0.8 = 88 W |
| 29 | a | Zero average power is why the choke saves energy |
| 30 | d | Wattless current is 90° out of phase |
Chapter 7 revision sheet
One-page summary
For v = V0 sin ωt and i = I0 sin(ωt − φ), instantaneous power p = vi has a steady part and a part at 2ω.
Average power: P = Vrms Irms cos φ = ½V0I0 cos φ.
Power factor cos φ = R/Z; it lies between 0 and 1, never above 1.
In any series circuit, P = Irms² R: only the resistance takes average power.
Pure R: cos φ = 1. Pure L or C: cos φ = 0, P = 0. Series LCR at resonance: cos φ = 1.
Apparent power = Vrms Irms, in volt-ampere (VA). True power = Vrms Irms cos φ, in watt.
Resolve the current into Irms cos φ (in phase with V, does the work) and Irms sin φ (90° out of phase, the wattless current).
Wattless current: Irms sin φ. It flows but does no average work.
A low power factor needs more current for the same useful power, so line losses I²R rise. Capacitors are added in factories to raise the power factor.
Instantaneous power can be negative for part of a cycle when φ is not zero: energy flows back to the source.
p swings between (V0I0/2)(cos φ + 1) and (V0I0/2)(cos φ − 1); its mean is (V0I0/2) cos φ.
Choke coil: a coil of large L and small R used to limit AC current (for example in old tube lights) while wasting very little power. A resistor would waste power as heat.
A choke cannot be used with DC; on DC only its small R limits the current.
Must-remember table
| Circuit | Power factor | Average power |
|---|---|---|
| Pure R | 1 | Vrms Irms |
| Pure L or pure C | 0 | 0 |
| Series RL or RC | R/Z | Irms² R |
| Series LCR at resonance | 1 | V²/R |
| Ideal choke | ≈ 0 | ≈ 0 |
| Apparent power | — | Vrms Irms in VA |
| Wattless current | — | Irms sin φ |
Memory aids
"Cos does the Work, Sin is the Shirker": I cos φ does work; I sin φ is wattless.
"Only R pays the bill": average power in a series circuit is Irms²R; L and C just borrow and return energy.
"Choke chokes, doesn't cook": a choke limits current without heating like a resistor.
"VA is the promise, W is the delivery": apparent power is never smaller than true power.
Concept connections
Joule heating P = I²R comes from Physics Book 12: Current Electricity.
Impedance and phase angle come from Chapter 6 of this book.
Line losses and the reason for high-voltage transmission link to the transformer in Chapter 8.
Practice MCQs: Chapter 7, Level 4 (new NEET pattern)
31. Match the circuit (List I) with its power factor (List II).
List I:
A. Pure resistor
B. Pure inductor
C. R = 30 Ω in series with XL = 40 Ω
D. R = 40 Ω in series with XC = 30 Ω
List II:
(i) 0
(ii) 0.6
(iii) 0.8
(iv) 1
(a) A-i, B-iv, C-ii, D-iii (b) A-iv, B-i, C-iii, D-ii (c) A-iv, B-i, C-ii, D-iii (d) A-iv, B-ii, C-i, D-iii
32. Match the term (List I) with its description (List II).
List I:
A. True power
B. Apparent power
C. Wattless current
D. Power factor of a series circuit
List II:
(i) Irms sin φ
(ii) Measured in watt
(iii) R/Z
(iv) Measured in volt-ampere
(a) A-ii, B-iv, C-i, D-iii (b) A-iv, B-ii, C-i, D-iii (c) A-ii, B-iv, C-iii, D-i (d) A-ii, B-i, C-iv, D-iii
33. A load draws 5 A rms from 220 V rms mains. Match the phase angle (List I) with the average power (List II).
List I:
A. φ = 0
B. φ = 60°
C. φ = 90°
D. cos φ = 0.8
List II:
(i) 0
(ii) 550 W
(iii) 880 W
(iv) 1100 W
(a) A-ii, B-iv, C-i, D-iii (b) A-iv, B-iii, C-i, D-ii (c) A-iv, B-ii, C-iii, D-i (d) A-iv, B-ii, C-i, D-iii
34. Match the practice (List I) with the reason (List II).
List I:
A. Choke coil in a tube light
B. Capacitor bank in a factory
C. Resistor used in place of a choke
D. Avoiding low power factor on supply lines
List II:
(i) Raises the power factor
(ii) For the same power, low cos φ means more current and more line loss
(iii) Limits current with little power loss
(iv) Wastes power as heat
(a) A-i, B-iii, C-iv, D-ii (b) A-iii, B-i, C-iv, D-ii (c) A-iii, B-iv, C-i, D-ii (d) A-iii, B-i, C-ii, D-iv
35. How many of the following statements are correct?
A. Average power = Vrms Irms cos φ.
B. The power factor of a capacitive circuit can exceed 1.
C. A series LCR circuit at resonance has power factor 1.
D. Wattless current is the part of the current in phase with the voltage.
E. An ideal choke takes no average power.
(a) 3 (b) 2 (c) 4 (d) 1
36. For a series RL circuit on AC, choose the correct set.
A. The instantaneous power oscillates at twice the source frequency.
B. The instantaneous power is negative for part of each cycle.
C. The average power equals Irms² R.
D. The average power equals Vrms Irms.
(a) A and D only (b) B, C and D only (c) A, B and C only (d) A and C only
37. How many of the following statements are correct?
A. Apparent power is never less than true power.
B. For the same power and voltage, the current is proportional to 1/cos φ.
C. Wattless current flows in a pure resistor.
D. For a series circuit, cos φ = R/Z.
(a) 1 (b) 2 (c) 4 (d) 3
38. For an ideal capacitor on AC, choose the correct set.
A. The energy taken in one quarter cycle is returned in the next.
B. The average power is zero.
C. The current through it is wattless.
D. It heats up like a resistor.
(a) A, B and C only (b) A and D only (c) B and D only (d) A, B, C and D
39. The instantaneous power p(t) of a circuit swings between a maximum of +300 W and a minimum of −100 W. The average power and power factor are: (a) 200 W, 0.5 (b) 100 W, 0.5 (c) 100 W, 0.33 (d) 150 W, 0.75
40. Three loads work on 220 V rms mains.
| Load | Irms (A) | Power factor |
|---|---|---|
| X | 10 | 1.0 |
| Y | 10 | 0.5 |
| Z | 5 | 0.8 |
The load taking the least true power, and the load with the largest wattless current, are: (a) Z, Y (b) Y, Y (c) Z, X (d) X, Y
41. The average power taken by a series LCR circuit is plotted against ω. If R is halved (L, C and V fixed): (a) the peak halves and the curve broadens (b) the peak doubles and ω0 shifts (c) the peak doubles and the curve becomes sharper (d) nothing changes
Case for Q42–43: A table fan behaves like a series RL load. On 220 V, 50 Hz mains it draws 2 A rms at a power factor of 0.8.
42. The average power drawn is: (a) 440 W (b) 352 W (c) 264 W (d) 176 W
43. The inductive reactance of the fan is: (a) 88 Ω (b) 110 Ω (c) 44 Ω (d) 66 Ω
44. A lamp rated 60 W, 120 V is to be run on 240 V, 50 Hz mains using a series capacitor. The capacitance needed is about: (a) 13.3 μF (b) 7.66 μF (c) 3.83 μF (d) 15.3 μF
45. A series LCR circuit with R = 20 Ω takes 500 W at resonance. The source rms voltage, and the rms current at a half-power frequency, are: (a) 100 V, 2.5 A (b) 50 V, 3.54 A (c) 100 V, 5 A (d) 100 V, 3.54 A
Level 4 answer key
| Q | Ans | Reason |
|---|---|---|
| 31 | c | 1; 0; 30/50 = 0.6; 40/50 = 0.8 |
| 32 | a | True power in W, apparent in VA, wattless current I sin φ, cos φ = R/Z |
| 33 | d | 1100 × cos φ: 1100, 550, 0, 880 W |
| 34 | b | Choke limits current cheaply; capacitors raise cos φ; resistor heats; low cos φ raises line loss |
| 35 | a | A, C, E true; cos φ is at most 1; wattless part is 90° out of phase |
| 36 | c | Average is Vrms Irms cos φ, not Vrms Irms |
| 37 | d | A, B, D true; in a pure resistor φ = 0, so no wattless current |
| 38 | a | No average power, so no heating |
| 39 | b | Mean = (300 − 100)/2 = 100 W; V0I0/2 = (300 + 100)/2 = 200 W; cos φ = 100/200 |
| 40 | a | Powers 2200, 1100, 880 W; wattless 0, 8.66, 3 A |
| 41 | c | Peak power V²/R doubles; Q = ω0L/R doubles; ω0 unchanged |
| 42 | b | 220 × 2 × 0.8 = 352 W |
| 43 | d | Z = 110 Ω, R = 88 Ω, XL = √(110² − 88²) = 66 Ω |
| 44 | b | R = 240 Ω, I = 0.5 A, Z = 480 Ω, XC = 415.7 Ω, C = 1/(100π × 415.7) = 7.66 μF |
| 45 | d | I² × 20 = 500 gives 5 A, so V = 100 V; half-power current 5/√2 = 3.54 A |