LATEST
JEEBy Pareeksha Editorial Team· ⏱ 19 min read

AC Phasor Diagrams and Power Factor for JEE

Share𝕏fin
Alongside this guide

Find study material for your next topic

Browse the Reading Room and preview a chapter before choosing what to study.

Browse study material →
AC Phasor Diagrams and Power Factor for JEE
On this page
  1. What this post covers
  2. Phasors: the three rules that settle every diagram
  3. Series circuits: reading the triangle backwards
  4. Parallel circuits: the voltage is the reference
  5. Power: real, reactive and apparent
  6. Power-factor correction with a parallel capacitor
  7. Worked examples
  8. Common traps
  9. A one-page recap
  10. How to practise this chapter
  11. Frequently asked questions
  12. Why does the current lag in an inductor but lead in a capacitor?
  13. What is the difference between power factor and efficiency?
  14. Can the power factor be greater than one?
  15. Does the power factor of an LCR circuit depend on frequency?
  16. Why is the reactive power not "lost" if it does no work?
  17. In a parallel LCR circuit which element carries the largest current?
  18. How should I draw a phasor diagram quickly in the exam?

The chapter guide on Alternating Current for JEE covers the whole chapter: rms values, reactance, resonance, Q factor, LC oscillations and transformers. This post takes one part of it much further. It is about drawing the phasor diagram correctly and reading everything from it: the impedance, the phase angle, the voltage across each element, the current in each branch of a parallel circuit, the real, reactive and apparent power, and the capacitor you must add to bring the power factor back to one. These are the questions in which students who know every formula still lose marks, because the formula they reach for depends on a diagram they have not drawn.

The approach here is deliberately geometric. A phasor is an arrow whose length is the peak (or rms) value of a quantity and whose angle is its phase. Adding two sinusoids of the same frequency becomes adding two arrows. Almost every AC problem at JEE Main level reduces to one right-angled triangle, and once you see which triangle, the arithmetic is a Pythagoras sum. There are twelve worked problems below, each checked by computation. They are different from the ten in the chapter guide, so work through both.

What this post covers

Part Question types
Phasor rules Choosing a reference, direction of rotation, lead and lag
Series circuits Voltage triangle, impedance triangle, unknown element in a box
Parallel circuits Current triangle, admittance, branch currents that do not add arithmetically
Power Average, apparent and reactive power; wattless current
Power factor Lamps with a choke, motors, correction with a parallel capacitor
Graphs and phase Reading $v$ and $i$ from waveforms and from equations

All of this is in the JEE Main syllabus under alternating current. The numbers in the examples are our own.

Phasors: the three rules that settle every diagram

Rule 1: pick the quantity that is common and draw it first. In a series circuit the current is common to every element, so draw the current phasor along the horizontal axis and measure every voltage against it. In a parallel circuit the voltage is common, so draw the voltage along the axis and measure every current against it. Choosing the wrong reference is the most common cause of a wrong triangle.

Rule 2: the three single-element relationships. With the current as reference in a series circuit:

  • the voltage across a resistor, $V_R=IR$, is along the current (in phase);
  • the voltage across an inductor, $V_L=IX_L$, is $90^\circ$ ahead of the current (the current lags it);
  • the voltage across a capacitor, $V_C=IX_C$, is $90^\circ$ behind the current (the current leads it).

A short memory line that avoids sign mistakes: in an inductor the voltage leads, in a capacitor the current leads. Written as one word it is the familiar CIVIL, but any mnemonic you will actually remember will do.

Rule 3: add arrows, not magnitudes. Because $V_L$ and $V_C$ point in opposite directions, their combined effect is $V_L-V_C$ (or its absolute value), and the source voltage is the vector sum $$V=\sqrt{V_R^2+(V_L-V_C)^2}$$ The magnitudes $V_R$, $V_L$, $V_C$ on a voltmeter will, in general, add to more than $V$. A student who writes $V=V_R+V_L+V_C$ is adding magnitudes, which is wrong for any circuit except a pure resistor.

The angle by which the source voltage leads the current is $$\tan\phi=\frac{V_L-V_C}{V_R}=\frac{X_L-X_C}{R}$$ and it is positive (current lags) when the inductive effect wins, negative (current leads) when the capacitive effect wins. Dividing every side of the voltage triangle by $I$ gives the impedance triangle with sides $R$, $X_L-X_C$ and $Z$; this is the same triangle scaled, not a new one.

Also read: PV Diagrams and Cyclic Processes for JEE

Series circuits: reading the triangle backwards

Most JEE questions give you some of the sides and ask for the others. The useful skill is to run the triangle in both directions.

Given the voltmeter readings. In a series circuit three voltmeters read $V_R$, $V_L$ and $V_C$, and a fourth reads the source. The source reading is $\sqrt{V_R^2+(V_L-V_C)^2}$, and the power factor is $\cos\phi=\frac{V_R}{V}$. Note that $V_L$ or $V_C$ alone can be larger than $V$; that is not an error, as it happens whenever the circuit is near resonance.

Given the impedance and a phase angle. If $Z$ and $\phi$ are given, then $R=Z\cos\phi$ and $X=Z\sin\phi$, where $X=X_L-X_C$ is the net reactance. If the net reactance is positive the box contains more inductance than capacitance at that frequency; if negative, more capacitance.

The "black box" problem. A box with two terminals has a voltage $v=V_0\sin\omega t$ across it and a current $i=I_0\sin(\omega t-\phi)$ into it. The sign of $\phi$ tells you what the box is. A positive lag ($i$ behind $v$) means net inductive; a lead means net capacitive; zero means resistive or at resonance. The average power is $\tfrac12V_0I_0\cos\phi$ whichever way the box is built, and the resistance inside the box is $R=Z\cos\phi$ if it is a series combination. State which assumption you are making.

Frequency dependence of the phase. At low frequency $X_C=\frac{1}{\omega C}$ is large and $X_L=\omega L$ is small, so a series LCR circuit is capacitive. At high frequency it is inductive. The phase angle crosses zero at the resonant frequency $\omega_0=\frac{1}{\sqrt{LC}}$. A graph question that gives $\phi$ against $\omega$ is testing exactly this; the curve rises from near $-90^\circ$ through zero at $\omega_0$ to near $+90^\circ$.

Parallel circuits: the voltage is the reference

In a parallel circuit every branch has the same voltage, so draw $V$ along the axis. The currents then are:

  • the resistor branch: $I_R=\frac VR$, along $V$;
  • the inductor branch: $I_L=\frac{V}{X_L}$, $90^\circ$ behind $V$;
  • the capacitor branch: $I_C=\frac{V}{X_C}$, $90^\circ$ ahead of $V$.

The source current is the vector sum $$I=\sqrt{I_R^2+(I_C-I_L)^2}$$ and the phase angle is $\tan\phi=\frac{I_C-I_L}{I_R}$, here measured as the lead of the current over the voltage. Notice that the roles of $L$ and $C$ have swapped compared with the series case: in a parallel circuit a large inductor current means the circuit is inductive, but the inductor branch current is subtracted from the capacitor branch current, not added.

The admittance form is neat: $Y=\frac1Z=\sqrt{\frac{1}{R^2}+\left(\omega C-\frac{1}{\omega L}\right)^2}$. The parallel circuit is at resonance when $\omega C=\frac{1}{\omega L}$, which gives the same $\omega_0=\frac{1}{\sqrt{LC}}$, but now the impedance is at a maximum, equal to $R$, and the source current is at a minimum. Students who remember "resonance means maximum current" should remember that this belongs to the series circuit; the parallel circuit at resonance draws the least current from the source while a large current circulates between the inductor and the capacitor.

Power: real, reactive and apparent

For a load with voltage $V_{\text{rms}}$ and current $I_{\text{rms}}$ at phase angle $\phi$, there are three powers worth separating.

  • Average (real) power, in watts: $P=V_{\text{rms}}I_{\text{rms}}\cos\phi=I_{\text{rms}}^2R$. This is the power that does work or heats the resistance.
  • Reactive power, in volt-amperes reactive: $Q=V_{\text{rms}}I_{\text{rms}}\sin\phi$. It measures the energy that swings back and forth between the source and the inductor or capacitor.
  • Apparent power, in volt-amperes: $S=V_{\text{rms}}I_{\text{rms}}$, with $S^2=P^2+Q^2$.

The power triangle has $P$ along the base, $Q$ upright and $S$ as hypotenuse, and its angle is the same $\phi$. The ratio $\frac PS=\cos\phi$ is the power factor.

Where the formula comes from. The instantaneous power is $p=vi=V_0I_0\sin\omega t\,\sin(\omega t-\phi)$. Using $\sin A\sin B=\tfrac12[\cos(A-B)-\cos(A+B)]$ this becomes $$p=\tfrac12V_0I_0\cos\phi-\tfrac12V_0I_0\cos(2\omega t-\phi)$$ The second term oscillates at twice the supply frequency and averages to zero. The constant first term is the average power. This also explains why the instantaneous power can become negative during part of the cycle when $\phi\neq0$: the load is returning energy to the source.

Wattless current. The current can be split into a component in phase with the voltage, $I\cos\phi$, which carries the real power, and a component $90^\circ$ out of phase, $I\sin\phi$, which does no net work. The latter is the wattless (idle) component. In a pure inductor or capacitor all the current is wattless.

Why power factor matters on a supply line. A load needing power $P$ at voltage $V$ draws $I=\frac{P}{V\cos\phi}$. A lower power factor means more current for the same useful power, and the line loss $I^2R_{\text{line}}$ grows as $\frac{1}{\cos^2\phi}$. That is why a supplier insists that a motor or a fluorescent tube-light fitting should have a good power factor.

Power-factor correction with a parallel capacitor

An inductive load (a motor, a choke) has its current lagging the voltage. A capacitor connected in parallel draws a current that leads the voltage, and these two reactive currents partly cancel, while the real current is unchanged. So the supply current falls and the power factor rises, without changing the power the load consumes.

The method uses the power triangle:

  1. Find the real power $P$ and the reactive power $Q_1=P\tan\phi_1$ of the load.
  2. Decide the target power factor, giving $Q_2=P\tan\phi_2$ (zero for unity).
  3. The capacitor must supply the difference $Q_C=Q_1-Q_2$.
  4. A capacitor across voltage $V_{\text{rms}}$ supplies $Q_C=\frac{V_{\text{rms}}^2}{X_C}=V_{\text{rms}}^2\omega C$, so $C=\frac{Q_C}{\omega V_{\text{rms}}^2}$.

The capacitor must be in parallel (across the supply). A capacitor in series with the load changes the voltage across the load and is not how correction is done. Also, over-correction is possible: a very large capacitor makes the circuit capacitive and the power factor falls again, now leading.

Worked examples

All the numerical results below were checked in Python before being written here.

Example 1 (easy, numerical). A series circuit has $R=40\ \Omega$ and $X_L=30\ \Omega$ and a source of 200 V (rms). Find the current, the voltage across each element and the phase angle in degrees.

Solution. $Z=\sqrt{40^2+30^2}=50\ \Omega$, so $I=\frac{200}{50}=4$ A. Then $V_R=4\times40=160$ V and $V_L=4\times30=120$ V. Check: $\sqrt{160^2+120^2}=200$ V, as it should be, although $160+120=280$ V. The phase angle is $\tan^{-1}\frac{30}{40}=36.87^\circ$, current lagging. Answer: 4 A, 160 V, 120 V, $36.9^\circ$ lag.

Example 2 (easy to medium, single correct). In a series LCR circuit the voltmeters read 80 V across $R$, 150 V across $L$ and 90 V across $C$. The source voltage and the power factor are

(A) 320 V and 0.25 (B) 100 V and 0.8 (C) 160 V and 0.5 (D) 100 V and 0.6

Solution. Net reactive voltage $=150-90=60$ V. Then $V=\sqrt{80^2+60^2}=100$ V and $\cos\phi=\frac{80}{100}=0.8$. Answer: (B). Option (A) is the trap: it adds the three readings arithmetically ($80+150+90=320$).

Example 3 (medium, numerical). A coil of negligible capacitance takes 4.4 kW from a 220 V, 50 Hz supply at a power factor of 0.6 lagging. Find the line current, and the capacitance in microfarads of a capacitor to be connected in parallel to bring the power factor to unity.

Solution. The line current is $I=\frac{P}{V\cos\phi}=\frac{4400}{220\times0.6}=33.3$ A. With $\cos\phi=0.6$, $\tan\phi=\frac{0.8}{0.6}=\frac43$, so the reactive power is $Q=4400\times\frac43=5867$ var. For unity the capacitor must supply all of it: $C=\frac{Q}{\omega V^2}=\frac{5867}{314.16\times220^2}=3.86\times10^{-4}$ F $=386\ \mu$F. After correction the line current falls to $\frac{4400}{220}=20$ A. Answer: 33.3 A and about 386 $\mu$F. The fall from 33.3 A to 20 A is the whole point: the real power is unchanged but the line carries 40% less current.

Example 4 (medium, numerical). A load draws 5 A (rms) at a power factor of 0.6 lagging. Find the in-phase and the wattless components of the current.

Solution. In-phase component $=I\cos\phi=5\times0.6=3$ A. Wattless component $=I\sin\phi=5\times\sqrt{1-0.36}=5\times0.8=4$ A. Answer: 3 A and 4 A. The total is $\sqrt{3^2+4^2}=5$ A, again a right-angled triangle.

Example 5 (medium, numerical). A lamp rated 100 V, 50 W is to be run from a 200 V, 50 Hz supply using a pure inductor in series. Find the inductance in henry to two decimals.

Solution. The lamp is a resistor with $R=\frac{V^2}{P}=\frac{100^2}{50}=200\ \Omega$ and a rated current of $\frac{50}{100}=0.5$ A. For this current from a 200 V supply the circuit impedance must be $Z=\frac{200}{0.5}=400\ \Omega$. Then $X_L=\sqrt{Z^2-R^2}=\sqrt{400^2-200^2}=346.4\ \Omega$ and $L=\frac{X_L}{\omega}=\frac{346.4}{314.16}=1.10$ H. Check: voltage across the lamp is $0.5\times200=100$ V and across the inductor $0.5\times346.4=173.2$ V, and $\sqrt{100^2+173.2^2}=200$ V. Answer: 1.10 H. A resistor in series instead would need $200\ \Omega$ and waste as much power as the lamp; the inductor wastes none, which is why a choke is used.

Example 6 (medium, numerical). The voltage across a box is $v=200\sin\omega t$ volts and the current into it is $i=4\sin\left(\omega t-\frac\pi3\right)$ amperes. Find the average power, the apparent power in rms terms and the resistance if the box is a series RL circuit.

Solution. $V_{\text{rms}}=\frac{200}{\sqrt2}=141.4$ V and $I_{\text{rms}}=\frac{4}{\sqrt2}=2.83$ A. The phase difference is $\phi=60^\circ$ with the current lagging. The average power is $\tfrac12V_0I_0\cos\phi=\tfrac12\times200\times4\times0.5=200$ W. The apparent power is $V_{\text{rms}}I_{\text{rms}}=\tfrac12\times200\times4=400$ VA. The impedance is $Z=\frac{200}{4}=50\ \Omega$, so $R=Z\cos60^\circ=25\ \Omega$ and $X_L=Z\sin60^\circ=43.3\ \Omega$. Check: $I_{\text{rms}}^2R=8\times25=200$ W. Answer: 200 W, 400 VA, 25 $\Omega$.

Example 7 (medium, numerical). A resistor of $100\ \Omega$ and a capacitor are in series on a 50 Hz supply. For what capacitance, in microfarads to one decimal place, does the current lead the voltage by $45^\circ$?

Solution. $\tan\phi=\frac{X_C}{R}=1$, so $X_C=R=100\ \Omega$. Then $C=\frac{1}{\omega X_C}=\frac{1}{314.16\times100}=3.18\times10^{-5}$ F $=31.8\ \mu$F. Answer: 31.8 $\mu$F. Halving the capacitance would double $X_C$ to $200\ \Omega$ and the lead would increase to $\tan^{-1}2=63.4^\circ$.

Example 8 (medium, single correct). A resistor, an inductor and a capacitor are connected in parallel across a source. The branch currents (rms) are 3 A in the resistor, 8 A in the inductor and 4 A in the capacitor. The source current is

(A) 15 A (B) 7 A (C) 5 A (D) 9 A

Solution. The inductor and capacitor currents are in opposition, so the net reactive current is $8-4=4$ A, and $I=\sqrt{3^2+4^2}=5$ A. Answer: (C). The current lags the voltage (inductor current wins) with $\cos\phi=\frac35$. The total of the branch readings (15 A) is the trap.

Example 9 (medium to hard, numerical). A series circuit has $R=100\ \Omega$, $L=0.5$ H and $C=20\ \mu$F. At angular frequency $200\ \text{rad s}^{-1}$ find the impedance, the power factor, and whether the current leads or lags.

Solution. $X_L=200\times0.5=100\ \Omega$ and $X_C=\frac{1}{200\times20\times10^{-6}}=250\ \Omega$. The net reactance is $-150\ \Omega$, so $Z=\sqrt{100^2+150^2}=180.3\ \Omega$ and $\cos\phi=\frac{100}{180.3}=0.555$. As $X_C>X_L$ the current leads, by $\tan^{-1}1.5=56.3^\circ$. The resonant angular frequency is $\frac{1}{\sqrt{0.5\times20\times10^{-6}}}=316$ rad s$^{-1}$, so $200$ rad s$^{-1}$ is below resonance, in the capacitive region, as expected. Answer: 180 $\Omega$, 0.555, leading.

Example 10 (hard, multiple correct). A series circuit has $R=30\ \Omega$, $X_L=80\ \Omega$, $X_C=40\ \Omega$ and a source of 100 V rms. Which statements are correct?

(A) The rms current is 2 A. (B) The voltage across the inductor is 160 V. (C) The current leads the source voltage. (D) The average power is 120 W.

Solution. $Z=\sqrt{30^2+(80-40)^2}=50\ \Omega$, so $I=2$ A: (A) is correct. $V_L=2\times80=160$ V, more than the source, and (B) is correct. Since $X_L>X_C$ the current lags, so (C) is false. $P=I^2R=4\times30=120$ W, and also $VI\cos\phi=100\times2\times0.6=120$ W: (D) is correct. Answer: (A), (B) and (D). A multiple-correct question of this type is a good test of whether you can hold the voltage triangle in your head, since $V_C=80$ V and $V_R=60$ V also follow.

Example 11 (hard, numerical). A load draws 10 A from a 220 V supply at a power factor of 0.8 lagging. Find the real, reactive and apparent power, and the reactive power a capacitor must supply to correct the power factor to unity.

Solution. Apparent power $S=220\times10=2200$ VA. Real power $P=2200\times0.8=1760$ W. Reactive power $Q=2200\times\sin\phi=2200\times0.6=1320$ var. Check: $\sqrt{1760^2+1320^2}=2200$. The capacitor must supply $Q_C=1320$ var. Answer: 1760 W, 1320 var, 2200 VA, 1320 var. Note that the capacitor's rating in var is a different number from its rating in farads; the farads depend on $\omega V^2$, as in Example 3.

Example 12 (hard, numerical). The circuit of Example 10 ($R=30\ \Omega$, $X_L=80\ \Omega$, $X_C=40\ \Omega$ at the original frequency, 100 V rms source) is run at double the frequency with $R$, $L$ and $C$ unchanged. Find the new rms current in amperes to two decimals.

Solution. At double the frequency $X_L$ doubles to $160\ \Omega$ and $X_C$ halves to $20\ \Omega$, so the net reactance is $140\ \Omega$ and $Z=\sqrt{30^2+140^2}=143.18\ \Omega$. The current is $\frac{100}{143.18}=0.70$ A. The circuit has become more inductive (the phase angle has grown from $53^\circ$ to $78^\circ$) and draws much less current. Answer: 0.70 A.

Common traps

  1. Adding the three voltmeter readings. Only $V_R$ is in phase with the current; $V_L$ and $V_C$ oppose each other. Always use $\sqrt{V_R^2+(V_L-V_C)^2}$.

  2. Using the series reference in a parallel problem. In a parallel circuit the common quantity is the voltage. Drawing the current as reference there flips the lead and lag of every branch.

  3. Taking resonance in a parallel circuit to mean maximum current. The parallel circuit has the minimum source current and maximum impedance at resonance. The maximum-current statement belongs only to the series circuit.

  4. Reading the sign of $\phi$ from the wrong element. The phase angle is positive (current lags) when $X_L>X_C$ in series. A circuit with a very large capacitor value has a small $X_C$ and is mostly inductive, even though it contains a capacitor.

  5. Treating the capacitance for power-factor correction as a series element. The correcting capacitor goes in parallel across the supply. In series it would change the load voltage and the load power.

  6. Mixing peak and rms in $P=VI\cos\phi$. Use rms for both, or write $\tfrac12V_0I_0\cos\phi$. Using $V_0$ with $I_{\text{rms}}$ is off by $\sqrt2$.

  7. Confusing power factor with the angle. A question may give $\phi=60^\circ$ and ask for the power factor, which is $0.5$, not $60$ or $\tfrac\pi3$. The converse is as common: a given factor of 0.8 means $\phi=36.9^\circ$, not $0.8$ rad.

  8. Reporting "zero power" for a circuit with zero phase angle. At unity power factor the real power equals the apparent power and is at its maximum for the given $V$ and $I$. Zero average power is for $\phi=90^\circ$.

  9. Forgetting that the supply current is not the load current. After correction the load still draws its original current; it is the line (supply) current that falls. A question asking "the current through the coil" after the capacitor is added has the same answer as before.

  10. Applying the series impedance formula to a parallel circuit. The parallel formula uses admittances, $Y=\sqrt{G^2+B^2}$, or currents.

  11. Rounding the angle before using it. A power factor like $\frac35$ is exact. Carrying $53^\circ$ into a later step introduces a small but visible error in a two-decimal answer.

  12. Overlooking over-correction. If the correcting capacitor is more than needed, the net reactive power is capacitive and the power factor falls again. An answer that increases without bound as $C$ grows is wrong.

A one-page recap

Item Result
Series reference current (common); $V_R$ along it, $V_L$ ahead by $90^\circ$, $V_C$ behind by $90^\circ$
Voltage triangle $V=\sqrt{V_R^2+(V_L-V_C)^2}$ ; $\cos\phi=\frac{V_R}{V}$
Impedance triangle $Z=\sqrt{R^2+X^2}$ ; $R=Z\cos\phi$ ; $X=Z\sin\phi$
Parallel reference voltage (common)
Parallel currents $I=\sqrt{I_R^2+(I_C-I_L)^2}$ ; $Y=\sqrt{G^2+B^2}$
Parallel resonance $\omega_0=\frac{1}{\sqrt{LC}}$, minimum source current
Real, reactive, apparent power $P=VI\cos\phi$ ; $Q=VI\sin\phi$ ; $S=VI$ ; $S^2=P^2+Q^2$
Instantaneous power constant term plus a term at $2\omega$
Wattless current $I\sin\phi$
Correction capacitor $C=\frac{P(\tan\phi_1-\tan\phi_2)}{\omega V^2}$, in parallel
Line loss $\frac{P^2R_{\text{line}}}{V^2\cos^2\phi}$

Also read: Linear Differential Equations in Telugu: Integrating Factor

How to practise this chapter

Begin with the chapter tests, which cover the whole chapter at the difficulty you will meet in the exam. The first is Alternating Current, test 1, and the chapter has seven tests, so continue with test 2 and test 3. Each has 15 questions in 36 minutes. The Topic Drill on LC oscillations is a good partner for the resonance side of the chapter. The study chapter is in English, Hindi and Telugu.

A seven-day plan built around diagrams:

  • Day 1. Redraw Examples 1 to 5 without looking, then change one number in each and solve again.
  • Day 2. Black-box problems: write twelve pairs of $v$ and $i$ equations and say what the box is.
  • Day 3. Parallel circuits and admittance; compare series and parallel resonance in one table.
  • Day 4. Power triangle problems and wattless current, including the power factor from a graph of $p$ against time.
  • Day 5. Power-factor correction, with and without over-correction; line loss at different power factors.
  • Day 6. Examples 10 to 12 and the multiple-correct style; revisit the graph methods in graph and figure-based questions.
  • Day 7. Chapter test 1 timed, an error log entry for every miss (the method is in error log and mock analysis), and a retry of the misses the next morning.

For the transient side of the same circuits, where the current builds up rather than settling into steady oscillation, read LR, RC and LC circuit transients. For the machines that produce and transform AC, see the sibling post Transformers and AC generators for JEE. For a general routine on a hard physics question, the Physics problem-solving framework applies. The cluster overview is Magnetism, EMI and Alternating Current for JEE.

When the chapter feels steady, move to mixed work, for example JEE Main Physics Practice Test 06, and then a full paper such as JEE Main Mock 5. Full mocks, practice tests and chapter tests are part of the Pro Pass; the free JEE Main mini mock needs no sign-up.

Frequently asked questions

Why does the current lag in an inductor but lead in a capacitor?

In an inductor the induced emf opposes the change in current, so the current has to be built up against it and trails the applied voltage by a quarter cycle. In a capacitor the current is $C\frac{dv}{dt}$, which is largest when the voltage is changing fastest, that is, when the voltage is zero; so the current peaks a quarter cycle before the voltage does.

What is the difference between power factor and efficiency?

Power factor is $\cos\phi$ and describes the phase between voltage and current at the input of a load. Efficiency is the ratio of useful output power to input power. A motor can have a poor power factor and a good efficiency, or the reverse; they answer different questions.

Can the power factor be greater than one?

No. $\cos\phi$ lies between $0$ and $1$. If your calculation gives a value above one, the voltage triangle or the impedance triangle was set up with a wrong side as hypotenuse. The hypotenuse is always the total ($V$, $Z$ or $S$).

Does the power factor of an LCR circuit depend on frequency?

Yes. $\cos\phi=\frac{R}{Z}=\frac{R}{\sqrt{R^2+(\omega L-\frac{1}{\omega C})^2}}$. It equals one at resonance and falls on both sides, faster for a circuit with a larger $L$ or a smaller $R$, which is the same fact as a high Q factor.

Why is the reactive power not "lost" if it does no work?

Reactive power describes energy that is stored in the field of the inductor or capacitor in one quarter cycle and returned to the source in the next. It does not appear as heat, but the current that carries it still flows through the wires and produces $I^2R$ loss there. That is why suppliers prefer a power factor near one.

In a parallel LCR circuit which element carries the largest current?

There is no general rule; it depends on the values. At resonance in an ideal parallel circuit the inductor and capacitor currents are equal and opposite, so a large current can flow in them while the source delivers only $I_R$.

How should I draw a phasor diagram quickly in the exam?

Write the common quantity (current for series, voltage for parallel) as a horizontal arrow, then add the resistor arrow along it, the inductor arrow up and the capacitor arrow down for a series voltage diagram. Close the triangle and read the hypotenuse. Ten seconds on the sketch usually saves a minute of algebra.

Now test yourself: free, no sign-up to start

Share:𝕏fin
Put what you read into practice

Find study material for your next topic

Browse the Reading Room and preview a chapter before choosing what to study.

Browse study material →

Make this reading part of your preparation

Create your free account to bookmark Reading Room chapters and track your practice scores. You’ll return to this article after signing in.

By continuing, you agree to our terms and privacy policy.

No payment needed. Already registered? Use the same options to sign in.

Comments (0)

Sign in to join the discussion.

No comments yet. Be the first to share your thoughts.